The Supra-Condlylar Nail is intended to be used as part of a compatible orthopedic internal fixation system according to the approved indications, surgical technique, and Instructions for Use. The exact anatomical applications, fracture indications, compatible locking screws, instrumentation, and surgical approach should be confirmed from the official technical documentation.
The product is shown as a long intramedullary nail with supracondylar and interlocking fixation features. Both material variants have a 9 mm diameter and are available in lengths from 150 mm to 360 mm. Selection of nail length, diameter, material variant, and associated fixation components should be performed according to the applicable anatomy, fracture characteristics, bone dimensions, patient requirements, and approved surgical plan.
According to the provided product information, the product family is identified as:
Product Name: Supra-Condlyar Nail
The product family has the following specifications shown in the image:
Diameter: 9 mm
Material Variants: TIT and Stainless Steel (316L)
Available Lengths: 150 mm, 200 mm, 220 mm, 240 mm, 260 mm, 280 mm, 300 mm, 320 mm, 340 mm, and 360 mm
Number of Configurations: 10 per material variant; 20 total identified entries
The product name spelling Supra-Condlyar is reproduced as shown in the supplied image. Any standardized product-name spelling should be confirmed from the official technical documentation.
The material notation TIT is also reproduced exactly as shown in the supplied image. Its expanded material designation and applicable material standard should be confirmed from the official technical documentation.
Each length and material variant is assigned an individual Cat. No. and GTIN No., supporting accurate implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.
Product Explanation
The Supra-Condlyar Nail is an orthopedic intramedullary fixation implant used within a compatible distal femoral or supracondylar fracture fixation construct. It is positioned within the applicable medullary canal and used with compatible interlocking fixation components according to the approved surgical technique and product documentation.
A simplified fixation concept can be represented as:
Supracondylar / Distal Femoral Fracture → Supra-Condlyar Nail → Compatible Locking Components → Internal Fixation Construct
Nail diameter and length are selected according to the patient’s anatomy, medullary canal dimensions, fracture location and pattern, required fixation levels, bone quality, and the surgical plan. Material selection should be made according to the applicable product documentation and clinical requirements.
Product Components and Design
- Intramedullary Nail Body
The supplied image shows long intramedullary nail components intended for placement within a compatible femoral bone canal. Both variants are identified with a 9 mm diameter. The detailed cross-sectional geometry, curvature, wall thickness, and mechanical specifications are not defined in the supplied image.
- Supracondylar Fixation Features
The product is identified as a Supra-Condlyar Nail and the supplied illustrations show fixation components associated with the distal portion of the nail. The exact number, position, dimensions, orientation, and compatibility of the reconstruction or locking holes and screws should be confirmed from the official technical documentation.
- Proximal and Distal Fixation
The product illustrations represent an intramedullary fixation construct with proximal and distal fixation features. The precise locking configuration, screw specifications, targeting method, and instrumentation are not specified in the supplied image.
- Material Variants
The supplied image identifies two material variants:
- TIT, reproduced as shown in the image. The expanded designation should be confirmed from official documentation.
- Stainless Steel (316L).
The material variant must be matched with the applicable Cat. No., GTIN No., surgical set, and product documentation.
- Diameter Configuration
Both material variants are identified with a diameter of:
9 mm
- Length-Specific Configurations
Each material variant is available in ten length options:
150 / 200 / 220 / 240 / 260 / 280 / 300 / 320 / 340 / 360 mm
The sequence is not uniformly spaced across the full range: the first interval is 50 mm from 150 mm to 200 mm, followed by 20 mm increments from 200 mm to 360 mm.
Intended Use
The Supra-Condlyar Nail is designed for use within a compatible orthopedic internal fixation system according to the approved indications, surgical technique, and Instructions for Use.
The supplied image alone does not define the complete clinical indication, fracture classification, patient population, associated locking screws, surgical approach, contraindications, or material-selection criteria. These details should be confirmed from the official product documentation and applicable regulatory information.
Nail selection and use depend on factors including:
- Applicable femoral anatomy.
- Medullary canal dimensions.
- Supracondylar or distal femoral fracture location and pattern.
- Required nail diameter.
- Required nail length.
- Proximal and distal fixation requirements.
- Material compatibility and applicable product requirements.
- Bone quality.
- Compatible locking screws and instrumentation.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Features
9 mm Nail Diameter
Both material variants are identified with a diameter of:
9 mm
Two Material Variants
The supplied image presents two variants:
- TIT, as written in the image.
- Stainless Steel (316L).
The expanded material designation for TIT should be confirmed from official technical documentation.
Length Range
Each material variant is available in lengths ranging from:
150 mm to 360 mm
providing multiple options for supracondylar nail selection.
Ten Length Configurations
Each material variant includes ten listed length configurations:
150 mm, 200 mm, 220 mm, 240 mm, 260 mm, 280 mm, 300 mm, 320 mm, 340 mm, and 360 mm
The first length interval is 50 mm, followed by regular 20 mm increments from 200 mm onward.
Supracondylar Nail Design
The product is identified as a Supra-Condlyar Nail and is shown as a long intramedullary nail used with associated fixation components in distal femoral fixation illustrations.
20 Identified Product Entries
The image presents ten length configurations for each of two material variants, resulting in:
20 identified length-and-material entries
Product Traceability
Each length and material variant has an individual Cat. No. and GTIN No. to support implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.
Technical Specifications — TIT Variant
| Material | Diameter | Length | Cat. No. | GTIN No. |
| TIT | 9 mm | 150 mm | AMS 816.009.015T | 6221361004023 |
| TIT | 9 mm | 200 mm | AMS 816.009.020T | 6221361004047 |
| TIT | 9 mm | 220 mm | AMS 816.009.022T | 6221361004061 |
| TIT | 9 mm | 240 mm | AMS 816.009.024T | 6221361004085 |
| TIT | 9 mm | 260 mm | AMS 816.009.026T | 6221361004108 |
| TIT | 9 mm | 280 mm | AMS 816.009.028T | 6221361004122 |
| TIT | 9 mm | 300 mm | AMS 816.009.030T | 6221361004146 |
| TIT | 9 mm | 320 mm | AMS 816.009.032T | 6221361004160 |
| TIT | 9 mm | 340 mm | AMS 816.009.034T | 6221361004184 |
| TIT | 9 mm | 360 mm | AMS 816.009.036T | 6221361004207 |
Technical Specifications — Stainless Steel (316L) Variant
| Material | Diameter | Length | Cat. No. | GTIN No. |
| Stainless Steel (316L) | 9 mm | 150 mm | AMS 816.009.015S | 6221361003811 |
| Stainless Steel (316L) | 9 mm | 200 mm | AMS 816.009.020S | 6221361003835 |
| Stainless Steel (316L) | 9 mm | 220 mm | AMS 816.009.022S | 6221361003859 |
| Stainless Steel (316L) | 9 mm | 240 mm | AMS 816.009.024S | 6221361003873 |
| Stainless Steel (316L) | 9 mm | 260 mm | AMS 816.009.026S | 6221361003897 |
| Stainless Steel (316L) | 9 mm | 280 mm | AMS 816.009.028S | 6221361003910 |
| Stainless Steel (316L) | 9 mm | 300 mm | AMS 816.009.030S | 6221361003934 |
| Stainless Steel (316L) | 9 mm | 320 mm | AMS 816.009.032S | 6221361003958 |
| Stainless Steel (316L) | 9 mm | 340 mm | AMS 816.009.034S | 6221361003972 |
| Stainless Steel (316L) | 9 mm | 360 mm | AMS 816.009.036S | 6221361003996 |
Variant Comparison
| Specification | TIT Variant | Stainless Steel Variant |
| Diameter | 9 mm | 9 mm |
| Material notation | TIT, as shown in the image | Stainless Steel (316L) |
| Available lengths | 150–360 mm | 150–360 mm |
| Listed lengths | 150, 200, 220–360 mm | 150, 200, 220–360 mm |
| Length pattern | 150 to 200 mm, then 20 mm increments | 150 to 200 mm, then 20 mm increments |
| Number of configurations | 10 | 10 |
| Cat. No. suffix shown | T | S |
| GTIN assignment | Individual GTIN for each length | Individual GTIN for each length |
The table above summarizes only the information visible in the supplied image. The Cat. No. suffixes are reported as shown and should not be interpreted as material codes beyond the material information explicitly displayed in the image.
Technical Overview
Product Name as Shown: Supra-Condlyar Nail
Product Type: Intramedullary Orthopedic Fixation Implant
Product Category: Supracondylar / Reconstruction Nail
Diameter: 9 mm
Material Variants: TIT and Stainless Steel (316L)
Available Lengths: 150–360 mm
Listed Lengths: 150 mm, 200 mm, and 220–360 mm
Number of Configurations: 10 per material variant; 20 total identified entries
Design: Intramedullary Nail with Supracondylar and Interlocking Fixation
Fixation Concept: Intramedullary Nail with Reconstruction and Interlocking Fixation
Anatomical Application: Compatible distal femoral / supracondylar fixation procedures; confirm the specific application from official documentation
Identification: Individual Cat. No. and GTIN No. for each length-and-material configuration
Product Features
- Supra-Condlyar Nail design as identified in the supplied image.
- 9 mm diameter for both displayed material variants.
- TIT material notation shown for one variant.
- Stainless Steel (316L) identified for the second variant.
- Intramedullary orthopedic fixation concept.
- Supracondylar, reconstruction, and interlocking fixation features shown in the product illustrations.
- Available in ten lengths per material variant.
- Length range from 150 mm to 360 mm.
- Listed lengths include 150 mm, 200 mm, and 220–360 mm.
- 20 identified length-and-material entries in total.
- Supports implant selection according to anatomy and fracture requirements.
- Individual Cat. No. for each length and material variant.
- Individual GTIN No. for each configuration.
- Supports implant identification, traceability, procurement, and inventory management.


Reviews