Gamma Nail (Ø 11 mm)

Gamma Nail | Diameter 11 mm | Right and Left | TIT and Stainless Steel (316L) Variants

The Gamma Nail is an orthopedic intramedullary fixation implant identified in the supplied product image. The image specifies an 11 mm diameter and presents two laterality options—Right and Left—together with two material variants: TIT and Stainless Steel (316L). Each laterality-and-material combination contains eight listed length configurations from 200 mm to 400 mm, providing 32 identified product entries in total.

 

  • Product name: Gamma Nail.
  • Diameter: 11 mm.
  • Laterality options: Right and Left.
  • Variant 1 material notation: TIT, as shown in the supplied image.
  • Variant 2 material: Stainless Steel (316L).
  • Listed lengths: 200 mm, 220 mm, 240 mm, 260 mm, 300 mm, 340 mm, 360 mm, and 400 mm.
  • The 180 mm, 280 mm, and 320 mm lengths are not shown in the supplied image.
  • Each length, laterality, and material combination has an individual Cat. No. and GTIN No.
  • The supplied image shows gamma nail components and associated fixation components in a proximal femoral fixation concept.

 

 

 

The Gamma Nail is intended to be used as part of a compatible orthopedic intramedullary fixation system according to the approved indications, surgical technique, and Instructions for Use. The exact fracture indications, anatomical requirements, laterality requirements, compatible locking screws, instrumentation, and surgical approach should be confirmed from the official technical documentation.

 

The product is shown with right- and left-sided configurations. Both material variants have an 11 mm diameter. The listed lengths range from 200 mm to 400 mm, with 180 mm, 280 mm, and 320 mm options absent from the supplied image. Selection of nail length, laterality, material variant, and associated fixation components should be performed according to the applicable anatomy, fracture characteristics, bone dimensions, patient requirements, and approved surgical plan.

 

According to the provided product information, the product family is identified as:

 

Product Name: Gamma Nail

 

The product family has the following specifications shown in the image:

 

Diameter: 11 mm

Laterality: Right and Left

Material Variants: TIT and Stainless Steel (316L)

Listed Lengths: 200 mm, 220 mm, 240 mm, 260 mm, 300 mm, 340 mm, 360 mm, and 400 mm

Number of Configurations: 8 per laterality-and-material combination; 32 total identified entries

 

The material notation TIT is reproduced exactly as shown in the supplied image. Its expanded material designation and applicable material standard should be confirmed from the official technical documentation.

 

The image legend identifies the black marker with Right and the blue marker with Left. The laterality assignment is reported as shown and must be verified against the official product labeling before use.

 

Each length, laterality, and material variant is assigned an individual Cat. No. and GTIN No., supporting accurate implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.

 

 

 

Product Explanation

The Gamma Nail is an orthopedic intramedullary fixation implant used within a compatible femoral fracture fixation construct. It is positioned within the applicable medullary canal and used with compatible proximal and distal fixation components according to the approved surgical technique and product documentation.

 

A simplified fixation concept can be represented as:

 

Proximal Femoral / Compatible Fracture Construct → Gamma Nail → Compatible Locking Components → Intramedullary Fixation Construct

 

Nail diameter, length, laterality, and material variant are selected according to the patient’s anatomy, fracture location and pattern, medullary canal dimensions, required fixation levels, bone quality, and the surgical plan.

 

 

 

Product Components and Design

  1. Intramedullary Nail Body

The supplied image shows gamma nail components intended for placement within a compatible medullary canal. The nail diameter is identified as 11 mm. The detailed cross-sectional geometry, curvature, wall thickness, and mechanical specifications are not defined in the supplied image.

 

  1. Right and Left Configurations

The product family includes right- and left-sided configurations. The image legend uses black and blue markers to identify the two sides. The exact laterality-specific geometry, angle, orientation, and compatibility requirements should be confirmed from the official technical documentation.

 

  1. Proximal and Distal Fixation Features

The product illustrations show associated fixation components at the proximal and distal regions of the nail. The exact number, position, dimensions, orientation, and compatibility of the locking holes or screws are not specified in the supplied image.

 

  1. Material Variants

The supplied image identifies two material variants:

 

  • TIT, reproduced as shown in the image. The expanded designation should be confirmed from official documentation.
  • Stainless Steel (316L).

 

The material variant must be matched with the applicable laterality, Cat. No., GTIN No., surgical set, and product documentation.

 

  1. Diameter Configuration

All listed configurations are identified with a diameter of:

 

11 mm

 

  1. Length-Specific Configurations

Each laterality-and-material combination contains the following eight listed length options:

 

200 / 220 / 240 / 260 / 300 / 340 / 360 / 400 mm

 

The sequence is not uniformly spaced across the full range. The 180 mm, 280 mm, and 320 mm configurations are not shown in the supplied image.

 

 

 

Intended Use

The Gamma Nail is designed for use within a compatible orthopedic intramedullary fixation system according to the approved indications, surgical technique, and Instructions for Use.

 

The supplied image alone does not define the complete clinical indication, fracture classification, patient population, associated locking screws, laterality-specific surgical approach, contraindications, or material-selection criteria. These details should be confirmed from the official product documentation and applicable regulatory information.

 

Nail selection and use depend on factors including:

 

  • Applicable anatomy.
  • Fracture location and pattern.
  • Medullary canal dimensions.
  • Required nail diameter.
  • Required nail length.
  • Right- or left-sided anatomical requirements.
  • Proximal and distal fixation requirements.
  • Material compatibility and applicable product requirements.
  • Bone quality.
  • Compatible locking screws and instrumentation.
  • Preoperative planning.
  • Intraoperative assessment.

 

The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

 

 

 

Key Features

11 mm Nail Diameter

All listed configurations are identified with a diameter of:

 

11 mm

 

Right and Left Options

The supplied image identifies two laterality options:

 

  • Right, represented by the black legend marker.
  • Left, represented by the blue legend marker.

 

The laterality assignment should be confirmed from the official product labeling and technical documentation.

 

Two Material Variants

The supplied image presents two variants:

 

  • TIT, as written in the image.
  • Stainless Steel (316L).

 

The expanded material designation for TIT should be confirmed from official technical documentation.

 

Eight Listed Length Configurations

Each laterality-and-material combination includes:

 

200 mm, 220 mm, 240 mm, 260 mm, 300 mm, 340 mm, 360 mm, and 400 mm

 

The 180 mm, 280 mm, and 320 mm lengths are not shown in the supplied image.

 

Gamma Nail Design

The product is identified as a Gamma Nail and is shown with associated proximal and distal fixation components in a compatible intramedullary fixation concept.

 

32 Identified Product Entries

The image presents eight listed lengths for each of two lateralities and two material variants, resulting in:

 

32 identified length-, laterality-, and material-specific entries

 

Product Traceability

Each length, laterality, and material variant has an individual Cat. No. and GTIN No. to support implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.

 

 

 

Technical Specifications — TIT Variant

Laterality         Material            Diameter         Length Cat. No.              GTIN No.

Right    TIT         11 mm 200 mm            AMS 818.011.020T              6221361000483

Right    TIT         11 mm 220 mm            AMS 818.011.022T              6221361000506

Right    TIT         11 mm 240 mm            AMS 818.011.024T              6221361000520

Right    TIT         11 mm 260 mm            AMS 818.011.026T              6221361045798

Right    TIT         11 mm 300 mm            AMS 818.011.030T              6221361045804

Right    TIT         11 mm 340 mm            AMS 818.011.034T              6221361045811

Right    TIT         11 mm 360 mm            AMS 818.011.036T              6221361045828

Right    TIT         11 mm 400 mm            AMS 818.011.040T              6221361045835

Left      TIT         11 mm 200 mm            AMS 818.111.020T              6221361046023

Left      TIT         11 mm 220 mm            AMS 818.111.022T              6221361046030

Left      TIT         11 mm 240 mm            AMS 818.111.024T              6221361046047

Left      TIT         11 mm 260 mm            AMS 818.111.026T              6221361046054

Left      TIT         11 mm 300 mm            AMS 818.111.030T              6221361046061

Left      TIT         11 mm 340 mm            AMS 818.111.034T              6221361046078

Left      TIT         11 mm 360 mm            AMS 818.111.036T              6221361046085

Left      TIT         11 mm 400 mm            AMS 818.111.040T              6221361046092

 

 

Technical Specifications — Stainless Steel (316L) Variant

Laterality         Material            Diameter         Length Cat. No.              GTIN No.

Right    Stainless Steel (316L)             11 mm 200 mm            AMS 818.011.020S 6221361000292

Right    Stainless Steel (316L)             11 mm 220 mm            AMS 818.011.022S 6221361000315

Right    Stainless Steel (316L)             11 mm 240 mm            AMS 818.011.024S 6221361000339

Right    Stainless Steel (316L)             11 mm 260 mm            AMS 818.011.026S 6221361004566

Right    Stainless Steel (316L)             11 mm 300 mm            AMS 818.011.030S 6221361046573

Right    Stainless Steel (316L)             11 mm 340 mm            AMS 818.011.034S 6221361046580

Right    Stainless Steel (316L)             11 mm 360 mm            AMS 818.011.036S 6221361046597

Right    Stainless Steel (316L)             11 mm 400 mm            AMS 818.011.040S 6221361046603

Left      Stainless Steel (316L)             11 mm 200 mm            AMS 818.111.020S 6221361046795

Left      Stainless Steel (316L)             11 mm 220 mm            AMS 818.111.022S 6221361046801

Left      Stainless Steel (316L)             11 mm 240 mm            AMS 818.111.024S 6221361046818

Left      Stainless Steel (316L)             11 mm 260 mm            AMS 818.111.026S 6221361046825

Left      Stainless Steel (316L)             11 mm 300 mm            AMS 818.111.030S 6221361046832

Left      Stainless Steel (316L)             11 mm 340 mm            AMS 818.111.034S 6221361046849

Left      Stainless Steel (316L)             11 mm 360 mm            AMS 818.111.036S 6221361046856

Left      Stainless Steel (316L)             11 mm 400 mm            AMS 818.111.040S 6221361046863

 

 

Laterality and Variant Comparison

Specification Right    Left

Diameter         11 mm 11 mm

Available materials    TIT and Stainless Steel (316L)            TIT and Stainless Steel (316L)

Listed lengths              200, 220, 240, 260, 300, 340, 360, and 400 mm      200, 220, 240, 260, 300, 340, 360, and 400 mm

Number of entries      16         16

Cat. No. family shown            AMS 818.011.xxx        AMS 818.111.xxx

GTIN assignment        Individual GTIN for each length and material              Individual GTIN for each length and material

Specification TIT Variant       Stainless Steel Variant

Diameter         11 mm 11 mm

Laterality options       Right and Left Right and Left

Listed lengths              200, 220, 240, 260, 300, 340, 360, and 400 mm      200, 220, 240, 260, 300, 340, 360, and 400 mm

Number of entries      16         16

Cat. No. suffix shown              T            S

GTIN assignment        Individual GTIN for each length and side              Individual GTIN for each length and side

The tables above summarize only the information visible in the supplied image. The laterality assignment, Cat. No. suffixes, and material notation are reported as shown and should be confirmed against the official product documentation.

 

 

 

Technical Overview

Product Name: Gamma Nail

Product Type: Intramedullary Orthopedic Fixation Implant

Product Category: Gamma Nail

Diameter: 11 mm

Laterality: Right and Left

Material Variants: TIT and Stainless Steel (316L)

Listed Lengths: 200 mm, 220 mm, 240 mm, 260 mm, 300 mm, 340 mm, 360 mm, and 400 mm

Number of Configurations: 8 lengths × 2 sides × 2 materials = 32 identified entries

Design: Intramedullary Nail with Proximal and Distal Fixation Components

Fixation Concept: Gamma Nail Intramedullary Fixation

Anatomical Application: Compatible femoral fixation procedures; confirm the specific application from official documentation

Identification: Individual Cat. No. and GTIN No. for each length, laterality, and material combination

 

 

 

Product Features

  • Gamma Nail orthopedic intramedullary fixation design.
  • 11 mm diameter for all displayed configurations.
  • Right and Left laterality options.
  • TIT material notation shown for one variant.
  • Stainless Steel (316L) identified for the second variant.
  • Available in eight listed lengths: 200 mm, 220 mm, 240 mm, 260 mm, 300 mm, 340 mm, 360 mm, and 400 mm.
  • The 180 mm, 280 mm, and 320 mm lengths are not shown in the supplied image.
  • Sixteen identified entries per laterality.
  • Sixteen identified entries per material variant.
  • 32 identified length-, laterality-, and material-specific entries in total.
  • Proximal and distal fixation components shown in the product illustrations.
  • Individual Cat. No. for each length, side, and material variant.
  • Individual GTIN No. for each configuration.
  • Supports implant identification, traceability, procurement, and inventory management.

 

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.