Product Explanation
The Locking L Distal Radius Plate 2.4/2.7 mm is an orthopedic fixation plate intended to form part of a compatible internal fixation construct in the distal radius region.
A simplified fixation concept can be represented as:
Distal Radius → L-Shaped Locking Plate → Compatible Fixation Screws → Internal Fixation Construct
The plate is selected and positioned according to the anatomical side, fracture configuration, bone anatomy, fixation requirements, surgical plan, approved surgical technique, and Instructions for Use.
According to the supplied product information, the plate is available in:
Left / Right
configurations.
The product family also includes:
2 / 3 Head Holes
and
3 / 4 Shaft Holes
providing multiple plate configurations for implant selection.
The exact pairing of the listed head-hole and shaft-hole options should be confirmed from the official catalog.
Product Components and Design
- L-Shaped Plate Body
The implant consists of an elongated metallic plate with an expanded proximal or distal end that creates an L-type plate configuration.
The product is specifically identified as:
Locking L Distal Radius Plate
according to the supplied product image.
The exact anatomical contour, plate curvature, dimensions, and orientation of the L-shaped geometry should be confirmed from the manufacturer’s technical drawings.
- Head Section
According to the supplied product data, the plate is available with:
2 Head Holes
or
3 Head Holes
These configurations provide alternative fixation arrangements within the head section of the plate.
The exact screw type and compatibility assigned to each head hole are not specified in the supplied image.
- Shaft Section
The elongated shaft section is available with:
3 Shaft Holes
or
4 Shaft Holes
according to the supplied product information.
These options provide different shaft fixation configurations within the product family.
The exact plate length associated with each shaft-hole configuration is not provided.
- Multiple Fixation Opening Geometries
The supplied product image visually shows several fixation openings distributed along the plate body.
Circular and elongated openings are visible within the plate.
The exact technical function of each opening—such as locking fixation, compression, adjustment, or positioning—is not defined in the supplied image and should be confirmed from the approved surgical technique.
- Left and Right Configurations
The plate is available in:
Left / Right
alignment options.
This supports side-specific implant selection according to the anatomical side being treated.
- Material Options
According to the supplied product data, the plate is available in:
SS316L
and
Titanium
The exact Titanium alloy or grade is not stated in the supplied image and should be confirmed from the official material specification.
Intended Use
The Locking L Distal Radius Plate 2.4/2.7 mm is designed for use as part of a compatible orthopedic fixation system involving the distal radius, according to the approved indications, surgical technique, and Instructions for Use.
Potential applications may involve internal fixation of the distal radius where an L-shaped plate configuration is included within the approved indications.
The exact fracture classifications, anatomical indications, surgical approach, screw configuration, contraindications, and patient selection criteria should be confirmed from the manufacturer’s official documentation.
Plate selection may depend on factors including:
- Anatomical side.
- Distal radius anatomy.
- Fracture location and configuration.
- Required fixation construct.
- Required head-hole configuration.
- Required shaft-hole configuration.
- Bone dimensions.
- Bone quality.
- Plate geometry requirement.
- Compatible screw selection.
- Compatible instrumentation.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon according to the approved surgical technique and Instructions for Use.
Key Benefits
L-Shaped Plate Configuration
The product is specifically identified as:
Locking L Distal Radius Plate
providing a distinct L-shaped plate configuration within the compatible distal radius fixation system.
The specific biomechanical role and approved indications of this geometry should be confirmed from the official technical documentation.
Left and Right Anatomical Options
The plate is available in:
Left / Right
configurations, supporting selection according to the anatomical side.
Multiple Head Configurations
The product family includes:
2 Head Holes
and
3 Head Holes
providing alternative fixation configurations within the plate head.
Multiple Shaft Configurations
The product family includes:
3 Shaft Holes
and
4 Shaft Holes
allowing selection between different shaft fixation layouts.
Two Material Options
According to the supplied product data, the plate is available in:
SS316L
and
Titanium
2.4/2.7 mm Fixation System
The product is identified as:
Locking L Distal Radius Plate 2.4/2.7 mm
indicating its association with a compatible 2.4/2.7 mm orthopedic fixation system.
The exact screw diameter assigned to each opening should be confirmed from the official technical documentation.
Multiple Product Variants
Based on the supplied product information, the product family contains variations involving:
- 2 alignment options: Left / Right
- 2 head-hole options: 2 / 3
- 2 shaft-hole options: 3 / 4
- 2 material options: SS316L / Titanium
These parameters indicate a multi-configuration product family.
However, the supplied image does not establish that every option is available in every possible combination. Therefore, the exact number of catalog configurations should be confirmed from the official Cat. No. table.
Technical Specifications
| Specification | Product Data |
| Product Name | Locking L Distal Radius Plate 2.4/2.7 mm |
| Product Category | Trauma – Radius |
| Product Type | Locking Orthopedic Fixation Plate |
| Plate Configuration | L-shaped |
| Anatomical Region | Distal Radius |
| System Size | 2.4/2.7 mm |
| Alignment | Left, Right |
| Head Hole Options | 2, 3 |
| Shaft Hole Options | 3, 4 |
| Materials | SS316L, Titanium |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
| Plate Length | Not provided |
| Plate Width | Not provided |
| Plate Thickness | Not provided |
| Compatible Screw Details | Not provided |
| Titanium Grade | Not provided |
| Compatible Instrumentation | Not provided |
Technical Overview
Product Name: Locking L Distal Radius Plate 2.4/2.7 mm
Product Category: Trauma – Radius
Product Type: Locking Orthopedic Fixation Plate
Plate Type: L-shaped
Anatomical Region: Distal Radius
System: 2.4/2.7 mm
Alignment Options: Left and Right
Head Hole Options: 2 and 3
Shaft Hole Options: 3 and 4
Material Options: SS316L and Titanium
Plate Geometry: Elongated L-shaped fixation plate
Fixation Concept: Plate-and-screw internal fixation using a compatible orthopedic fixation system
Side-Specific Design: Yes — Left / Right
Cat. No.: Not supplied
GTIN No.: Not supplied
Specific Titanium Grade: Not supplied
Plate Dimensions: Not supplied
Specific Screw Compatibility: Not supplied
Product Features
- Locking distal radius plate design.
- Identified as an L-shaped plate configuration.
- Intended for use within a compatible distal radius fixation system.
- Associated with a 2.4/2.7 mm fixation system according to the product name.
- Available in Left and Right configurations.
- Available with 2 or 3 head holes.
- Available with 3 or 4 shaft holes.
- Available in SS316L.
- Available in Titanium.
- Features an elongated plate body.
- Features an expanded end forming the L-shaped configuration.
- Includes multiple fixation openings.
- Includes circular openings visible in the supplied image.
- Includes elongated openings visible in the supplied image.
- Supports side-specific implant selection.
- Supports multiple head-hole configurations.
- Supports multiple shaft-hole configurations.
- Provides a multi-variant plate family for different fixation requirements.
- Exact combinations of head-hole and shaft-hole options should be confirmed from the official catalog.
- Exact compatible screw types and diameters should be confirmed from the technical documentation.
- Exact plate dimensions and thickness should be confirmed from the manufacturer’s technical drawings.
- Individual Cat. No. and GTIN No. should be added when the official product table is available.
- Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).


Reviews