Locking Redial Head Neck Plate, 2.4 mm

 

Locking Redial Head Neck Plate, 2.4 mm | 2–4 Shaft Holes | SS316L / Titanium

The Locking Redial Head Neck Plate, 2.4 mm is an orthopedic fixation plate designed for use within a compatible fixation system involving the radial head/neck region.

According to the supplied product image, no alignment or separate head-hole configuration is specified. The plate is available with 2, 3, or 4 shaft holes and is manufactured from either SS316L or Titanium.

The supplied product information identifies:

  • Product Name: Locking Redial Head Neck Plate, 2.4 mm
  • Anatomical Region: Radial Head / Neck region, based on the product designation
  • Plate Configuration: Head Neck Plate
  • Alignment: Not specified
  • Head Holes: Not specified
  • Shaft Holes: 2, 3, 4
  • Material Options: SS316L, Titanium
  • System Size: 2.4 mm

The exact plate dimensions, number and classification of fixation openings within the expanded head section, plate thickness, screw compatibility, locking mechanism, screw trajectories, Cat. No., GTIN No., and compatible instrumentation are not provided in the supplied image and should be confirmed from the official technical documentation and Instructions for Use.

 

Product Explanation

The Locking Redial Head Neck Plate, 2.4 mm is an orthopedic fixation plate intended to form part of a compatible internal fixation construct.

A simplified fixation concept can be represented as:

Radial Head / Neck Region → Locking Head Neck Plate → Compatible Fixation Screws → Internal Fixation Construct

The product designation associates the plate with the radial head/neck region.

The plate is selected and positioned according to the applicable anatomy, fracture configuration, fixation requirements, bone characteristics, surgical plan, approved surgical technique, and Instructions for Use.

According to the supplied product information, the plate family is available with:

2 / 3 / 4 Shaft Holes

and in:

SS316L / Titanium

No specific Left / Right alignment or numerical head-hole configuration is provided in the supplied product data.

Product Components and Design

  1. Head-Neck Plate Body

The implant consists of a metallic plate with a broadened upper section and an elongated shaft.

The product is specifically identified as a:

Head Neck Plate

according to the supplied product name.

The supplied image visually shows a contoured expanded section transitioning into a narrower longitudinal shaft.

The exact anatomical contour, plate curvature, dimensions, and plate-to-bone relationship should be confirmed from the manufacturer’s technical drawings.

  1. Expanded Head Section

The upper portion of the plate incorporates several visible fixation openings.

However, the supplied product data states:

Head Holes: –

Therefore, a numerical head-hole specification should not be inferred solely from the visual appearance of the plate.

The exact number, classification, function, and compatible screw type for the openings in this section should be confirmed from the official technical documentation.

  1. Shaft Section

According to the supplied product information, the plate is available with:

2 Shaft Holes

3 Shaft Holes

4 Shaft Holes

These options provide multiple plate configurations within the same product family.

The exact physical plate length corresponding to each shaft-hole configuration is not provided in the supplied image.

  1. Multiple Fixation Opening Geometries

The supplied product image visually shows several different opening geometries distributed along the plate body.

These include:

  • Circular openings.
  • Elongated openings.
  • Multiple openings within the expanded upper section.
  • Openings distributed along the shaft.

The specific technical purpose of each opening—such as locking fixation, conventional fixation, compression, positioning, or adjustment—is not defined in the supplied information and should be confirmed from the approved surgical technique.

  1. Alignment

According to the supplied product data:

Alignment: –

No Left, Right, Straight, or other alignment designation is provided.

Therefore, the plate should not be described as side-specific based on the supplied image alone.

Whether different anatomical orientations or side-specific versions exist should be verified from the official catalog.

  1. Material Options

According to the supplied product information, the plate is available in:

SS316L

and

Titanium

The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the manufacturer’s material specification.

Intended Use

The Locking Redial Head Neck Plate, 2.4 mm is designed for use as part of a compatible orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.

Based on its product designation, the plate is associated with the radial head/neck anatomical region.

Potential applications may involve internal fixation procedures in this anatomical region when the plate is included within the manufacturer’s approved indications.

The exact fracture patterns, fracture classifications, anatomical indications, surgical approach, contraindications, screw configuration, and patient-selection criteria are not stated in the supplied image and should be confirmed from the official product documentation.

Plate selection may depend on factors including:

  • Radial head and neck anatomy.
  • Fracture location and configuration.
  • Required fixation construct.
  • Required shaft-hole configuration.
  • Required plate length.
  • Bone dimensions.
  • Bone quality.
  • Plate geometry.
  • Compatible screw selection.
  • Compatible instrumentation.
  • Surgical approach.
  • Preoperative planning.
  • Intraoperative assessment.

The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

Key Benefits

Head-Neck Plate Configuration

The product is specifically identified as a:

Locking Head Neck Plate

providing a distinct plate configuration within a compatible orthopedic fixation system.

The exact anatomical and biomechanical role of this configuration should be confirmed from the manufacturer’s official documentation.

Three Shaft-Hole Options

The product family is available with:

2 Shaft Holes

3 Shaft Holes

4 Shaft Holes

providing three different shaft configurations.

2.4 mm Fixation System

The product is identified as:

Locking Redial Head Neck Plate, 2.4 mm

indicating its association with a compatible 2.4 mm orthopedic fixation system.

The exact screw diameter, screw type, and hole-specific compatibility should be confirmed from the official technical documentation.

Two Material Options

The plate is available in:

SS316L

and

Titanium

according to the supplied product data.

Multiple Product Configurations

Based strictly on the supplied information, the family contains:

  • No specified alignment variants
  • No numerical head-hole variants specified
  • 3 shaft-hole options: 2 / 3 / 4
  • 2 material options: SS316L / Titanium

If each listed shaft configuration is available in both materials, this would represent up to 6 basic shaft × material combinations.

However, the supplied image does not confirm the complete commercial configuration matrix, so the exact number of variants should be verified against the official Cat. No. table.

Technical Specifications

Specification Product Data
Product Name Locking Redial Head Neck Plate, 2.4 mm
Product Category Trauma
Product Type Locking Orthopedic Fixation Plate
Plate Configuration Head Neck Plate
Anatomical Region Radial Head / Neck region, based on product designation
System Size 2.4 mm
Alignment Not specified
Head Holes Not specified
Shaft Hole Options 2, 3, 4
Materials SS316L, Titanium
Potential Basic Configurations Up to 6, subject to catalog confirmation
Cat. No. Not provided
GTIN No. Not provided
Plate Length Not provided
Plate Width Not provided
Plate Thickness Not provided
Compatible Screw Details Not provided
Screw Trajectories Not provided
Titanium Grade Not provided
Compatible Instrumentation Not provided

Technical Overview

Product Name: Locking Redial Head Neck Plate, 2.4 mm

Product Category: Trauma

Product Type: Locking Orthopedic Fixation Plate

Plate Type: Head Neck Plate

Anatomical Region: Radial Head / Neck region, based on the product designation

System: 2.4 mm

Alignment: Not specified

Head Holes: Not specified

Shaft Hole Options: 2, 3, and 4

Material Options: SS316L and Titanium

Plate Geometry: Broadened contoured upper section with elongated shaft

Fixation Concept: Plate-and-screw internal fixation using a compatible orthopedic fixation system

Side-Specific Design: Not specified

Cat. No.: Not supplied

GTIN No.: Not supplied

Specific Titanium Grade: Not supplied

Plate Dimensions: Not supplied

Specific Screw Compatibility: Not supplied

Product Features

  • Locking orthopedic fixation plate design.
  • Identified as a Head Neck Plate.
  • Associated with a 2.4 mm fixation system according to the product name.
  • Alignment is not specified in the supplied data.
  • No numerical head-hole configuration is specified.
  • Available with 2 shaft holes.
  • Available with 3 shaft holes.
  • Available with 4 shaft holes.
  • Available in SS316L.
  • Available in Titanium.
  • Features a broadened contoured upper plate section.
  • Features an elongated shaft.
  • Includes multiple visible fixation openings.
  • Includes circular openings visible in the supplied image.
  • Includes elongated openings visible in the supplied image.
  • Supports multiple shaft-hole configurations.
  • Supports two listed material options.
  • Exact classification and number of openings within the expanded head section should be confirmed from official documentation.
  • Exact compatible screw types and diameters should be confirmed from the manufacturer’s technical documentation.
  • Exact screw trajectories should be confirmed from the technical drawings.
  • Exact plate length, width, and thickness should be confirmed from the manufacturer’s product specifications.
  • Individual Cat. No. and GTIN No. should be added when the official product table is available.
  • Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top