Product Explanation
The Locking Redial Head Neck Plate, 2.4 mm is an orthopedic fixation plate intended to form part of a compatible internal fixation construct.
A simplified fixation concept can be represented as:
Radial Head / Neck Region → Locking Head Neck Plate → Compatible Fixation Screws → Internal Fixation Construct
The product designation associates the plate with the radial head/neck region.
The plate is selected and positioned according to the applicable anatomy, fracture configuration, fixation requirements, bone characteristics, surgical plan, approved surgical technique, and Instructions for Use.
According to the supplied product information, the plate family is available with:
2 / 3 / 4 Shaft Holes
and in:
SS316L / Titanium
No specific Left / Right alignment or numerical head-hole configuration is provided in the supplied product data.
Product Components and Design
- Head-Neck Plate Body
The implant consists of a metallic plate with a broadened upper section and an elongated shaft.
The product is specifically identified as a:
Head Neck Plate
according to the supplied product name.
The supplied image visually shows a contoured expanded section transitioning into a narrower longitudinal shaft.
The exact anatomical contour, plate curvature, dimensions, and plate-to-bone relationship should be confirmed from the manufacturer’s technical drawings.
- Expanded Head Section
The upper portion of the plate incorporates several visible fixation openings.
However, the supplied product data states:
Head Holes: –
Therefore, a numerical head-hole specification should not be inferred solely from the visual appearance of the plate.
The exact number, classification, function, and compatible screw type for the openings in this section should be confirmed from the official technical documentation.
- Shaft Section
According to the supplied product information, the plate is available with:
2 Shaft Holes
3 Shaft Holes
4 Shaft Holes
These options provide multiple plate configurations within the same product family.
The exact physical plate length corresponding to each shaft-hole configuration is not provided in the supplied image.
- Multiple Fixation Opening Geometries
The supplied product image visually shows several different opening geometries distributed along the plate body.
These include:
- Circular openings.
- Elongated openings.
- Multiple openings within the expanded upper section.
- Openings distributed along the shaft.
The specific technical purpose of each opening—such as locking fixation, conventional fixation, compression, positioning, or adjustment—is not defined in the supplied information and should be confirmed from the approved surgical technique.
- Alignment
According to the supplied product data:
Alignment: –
No Left, Right, Straight, or other alignment designation is provided.
Therefore, the plate should not be described as side-specific based on the supplied image alone.
Whether different anatomical orientations or side-specific versions exist should be verified from the official catalog.
- Material Options
According to the supplied product information, the plate is available in:
SS316L
and
Titanium
The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the manufacturer’s material specification.
Intended Use
The Locking Redial Head Neck Plate, 2.4 mm is designed for use as part of a compatible orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.
Based on its product designation, the plate is associated with the radial head/neck anatomical region.
Potential applications may involve internal fixation procedures in this anatomical region when the plate is included within the manufacturer’s approved indications.
The exact fracture patterns, fracture classifications, anatomical indications, surgical approach, contraindications, screw configuration, and patient-selection criteria are not stated in the supplied image and should be confirmed from the official product documentation.
Plate selection may depend on factors including:
- Radial head and neck anatomy.
- Fracture location and configuration.
- Required fixation construct.
- Required shaft-hole configuration.
- Required plate length.
- Bone dimensions.
- Bone quality.
- Plate geometry.
- Compatible screw selection.
- Compatible instrumentation.
- Surgical approach.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Benefits
Head-Neck Plate Configuration
The product is specifically identified as a:
Locking Head Neck Plate
providing a distinct plate configuration within a compatible orthopedic fixation system.
The exact anatomical and biomechanical role of this configuration should be confirmed from the manufacturer’s official documentation.
Three Shaft-Hole Options
The product family is available with:
2 Shaft Holes
3 Shaft Holes
4 Shaft Holes
providing three different shaft configurations.
2.4 mm Fixation System
The product is identified as:
Locking Redial Head Neck Plate, 2.4 mm
indicating its association with a compatible 2.4 mm orthopedic fixation system.
The exact screw diameter, screw type, and hole-specific compatibility should be confirmed from the official technical documentation.
Two Material Options
The plate is available in:
SS316L
and
Titanium
according to the supplied product data.
Multiple Product Configurations
Based strictly on the supplied information, the family contains:
- No specified alignment variants
- No numerical head-hole variants specified
- 3 shaft-hole options: 2 / 3 / 4
- 2 material options: SS316L / Titanium
If each listed shaft configuration is available in both materials, this would represent up to 6 basic shaft × material combinations.
However, the supplied image does not confirm the complete commercial configuration matrix, so the exact number of variants should be verified against the official Cat. No. table.
Technical Specifications
| Specification | Product Data |
| Product Name | Locking Redial Head Neck Plate, 2.4 mm |
| Product Category | Trauma |
| Product Type | Locking Orthopedic Fixation Plate |
| Plate Configuration | Head Neck Plate |
| Anatomical Region | Radial Head / Neck region, based on product designation |
| System Size | 2.4 mm |
| Alignment | Not specified |
| Head Holes | Not specified |
| Shaft Hole Options | 2, 3, 4 |
| Materials | SS316L, Titanium |
| Potential Basic Configurations | Up to 6, subject to catalog confirmation |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
| Plate Length | Not provided |
| Plate Width | Not provided |
| Plate Thickness | Not provided |
| Compatible Screw Details | Not provided |
| Screw Trajectories | Not provided |
| Titanium Grade | Not provided |
| Compatible Instrumentation | Not provided |
Technical Overview
Product Name: Locking Redial Head Neck Plate, 2.4 mm
Product Category: Trauma
Product Type: Locking Orthopedic Fixation Plate
Plate Type: Head Neck Plate
Anatomical Region: Radial Head / Neck region, based on the product designation
System: 2.4 mm
Alignment: Not specified
Head Holes: Not specified
Shaft Hole Options: 2, 3, and 4
Material Options: SS316L and Titanium
Plate Geometry: Broadened contoured upper section with elongated shaft
Fixation Concept: Plate-and-screw internal fixation using a compatible orthopedic fixation system
Side-Specific Design: Not specified
Cat. No.: Not supplied
GTIN No.: Not supplied
Specific Titanium Grade: Not supplied
Plate Dimensions: Not supplied
Specific Screw Compatibility: Not supplied
Product Features
- Locking orthopedic fixation plate design.
- Identified as a Head Neck Plate.
- Associated with a 2.4 mm fixation system according to the product name.
- Alignment is not specified in the supplied data.
- No numerical head-hole configuration is specified.
- Available with 2 shaft holes.
- Available with 3 shaft holes.
- Available with 4 shaft holes.
- Available in SS316L.
- Available in Titanium.
- Features a broadened contoured upper plate section.
- Features an elongated shaft.
- Includes multiple visible fixation openings.
- Includes circular openings visible in the supplied image.
- Includes elongated openings visible in the supplied image.
- Supports multiple shaft-hole configurations.
- Supports two listed material options.
- Exact classification and number of openings within the expanded head section should be confirmed from official documentation.
- Exact compatible screw types and diameters should be confirmed from the manufacturer’s technical documentation.
- Exact screw trajectories should be confirmed from the technical drawings.
- Exact plate length, width, and thickness should be confirmed from the manufacturer’s product specifications.
- Individual Cat. No. and GTIN No. should be added when the official product table is available.
- Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).


Reviews