Product Explanation
The Locking Head Bone Screw, Cannulated Self Tapping Ø 5.0 mm is an orthopedic fixation screw intended to form part of a compatible locking fixation construct.
A simplified fixation concept can be represented as:
Guide Wire / Prepared Fixation Path → Compatible Locking Implant → 5.0 mm Cannulated Locking Head Screw → Locked Fixation Construct
The product combines four principal supplied characteristics:
Locking Head
Cannulated
Self Tapping
Ø 5.0 mm nominal diameter
The cannulated configuration indicates the presence of an axial internal lumen intended for use with compatible guided instrumentation according to the approved surgical technique.
The locking head indicates compatibility with a manufacturer-defined locking fixation interface.
The exact guide-wire specification and locking-head geometry are not supplied and should not be inferred from the image alone.
Product Components and Design
- Locking Head
The product is specifically identified as a:
Locking Head Bone Screw
The proximal screw head is intended to interface with a compatible locking plate or fixation component.
The supplied data does not define:
- Locking-head thread pitch.
- Locking-head diameter.
- Locking interface geometry.
- Locking angle.
- Variable-angle capability.
- Compatible locking plate-hole geometry.
These specifications should be confirmed from the manufacturer’s engineering documentation.
- Cannulated Screw Body
The product is specifically identified as:
Cannulated
indicating an internal axial lumen through the screw body.
The exact:
- Cannulation diameter.
- Guide-wire diameter.
- Guide-wire compatibility.
- Cannulation tolerance.
- Internal lumen geometry.
are not supplied.
The technically safe wording is:
Cannulation: Present — exact internal diameter and guide-wire compatibility not specified
- Ø 5.0 mm Nominal Diameter
The supplied product title specifies:
Ø 5.0 mm
as the nominal screw diameter.
The source does not separately provide:
- Major thread diameter.
- Minor / core diameter.
- Thread depth.
- Thread pitch.
- Thread profile.
- Dimensional tolerances.
These parameters should be confirmed from the official dimensional drawing.
- Self-Tapping Design
The product is specifically identified as:
Self Tapping
indicating a manufacturer-defined self-tapping tip / thread-entry configuration.
The exact:
- Cutting flute geometry.
- Tip design.
- Thread-start configuration.
- Drilling requirements.
- Tapping requirements.
are not defined in the supplied product image.
- Threaded Shaft
The supplied image visually shows external threading extending along the screw shaft.
The exact:
- Thread pitch.
- Thread depth.
- Thread lead.
- Threaded length.
- Core diameter.
- Thread flank geometry.
are not supplied.
- Distal Tip
The distal end has a defined geometry associated with the screw’s Self Tapping designation.
However, the source does not state:
Self Drilling
Therefore, self-drilling capability should not be added to the product specification unless confirmed by official documentation.
- Drive Interface
The supplied image shows an insertion interface within the proximal screw head.
However, the exact drive geometry is not specified.
Therefore, the technical sheet should not identify the interface as:
Hex / Torx / Star / Stardrive / other
without official confirmation.
Length Configurations
According to the supplied product information:
Length: 30–90 mm (5 mm Variation)
This provides the following configurations:
| No. | Length |
| 1 | 30 mm |
| 2 | 35 mm |
| 3 | 40 mm |
| 4 | 45 mm |
| 5 | 50 mm |
| 6 | 55 mm |
| 7 | 60 mm |
| 8 | 65 mm |
| 9 | 70 mm |
| 10 | 75 mm |
| 11 | 80 mm |
| 12 | 85 mm |
| 13 | 90 mm |
Therefore:
Total Length Configurations: 13
Material Options
According to the supplied product data, the screw is available in:
SS316L
and
Titanium
The exact Titanium alloy or grade is not specified and should be confirmed from the manufacturer’s official material documentation.
Intended Use
The Locking Head Bone Screw, Cannulated Self Tapping Ø 5.0 mm is designed for use as part of a compatible locking orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.
Potential applications may involve fixation where a compatible 5.0 mm cannulated locking head screw is specified by the manufacturer.
The exact anatomical indications, compatible locking plates or fixation components, guide-wire requirements, and screw-placement technique are not supplied in the image.
Screw selection may depend on factors including:
- Anatomical location.
- Compatible locking implant.
- Required screw diameter.
- Required screw length.
- Bone dimensions.
- Bone quality.
- Required fixation construct.
- Compatible guide wire.
- Screw trajectory.
- Compatible drilling instrumentation.
- Compatible depth gauge.
- Compatible screwdriver.
- Preoperative planning.
- Intraoperative measurement.
The screw should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Benefits
Cannulated Design
The product is specifically identified as:
Cannulated
indicating an internal lumen intended for use within a compatible guided fixation system.
The exact guide-wire size should be confirmed from official system documentation.
Locking Head Configuration
The product is specifically identified as a:
Locking Head Bone Screw
indicating compatibility with a manufacturer-defined locking fixation interface.
The exact locking-head geometry should be confirmed from the manufacturer’s technical documentation.
Self-Tapping Design
The product is specifically identified as:
Self Tapping
providing a manufacturer-defined self-tapping thread-entry configuration.
Ø 5.0 mm Nominal Diameter
The screw provides a nominal:
5.0 mm diameter
within the compatible fixation system.
30–90 mm Length Range
The screw is available from:
30 mm to 90 mm
providing multiple length options within the same diameter family.
5 mm Length Increments
The complete supplied range uses:
5 mm increments
allowing standardized length progression.
13 Length Configurations
The complete available range is:
30 / 35 / 40 / 45 / 50 / 55 / 60 / 65 / 70 / 75 / 80 / 85 / 90 mm
providing:
13 individual length options
Two Material Options
According to the supplied product information, the screw is available in:
SS316L
and
Titanium
Multiple Product Variants
Based strictly on the supplied product information, the family includes:
- 1 nominal diameter: Ø 5.0 mm
- 1 cannulated configuration
- 1 locking-head configuration
- 1 self-tapping configuration
- 13 length options
- 2 material options: SS316L / Titanium
If every listed length is available in both materials, this could theoretically represent:
13 × 2 = up to 26 basic length × material configurations
The exact commercial matrix should be confirmed from the official Cat. No. / GTIN table.
Technical Specifications
| Specification | Product Data |
| Product Name | Locking Head Bone Screw, Cannulated Self Tapping Ø 5.0 mm |
| Product Category | Trauma – Screw |
| Product Type | Cannulated Locking Head Bone Screw |
| Head Type | Locking Head |
| Cannulated | Yes |
| Self Tapping | Yes |
| Self Drilling | Not specified |
| Nominal Diameter | Ø 5.0 mm |
| Length Range | 30–90 mm |
| Length Increment | 5 mm |
| Available Lengths | 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90 mm |
| Number of Length Options | 13 |
| Materials | SS316L, Titanium |
| Potential Basic Configurations | Up to 26, subject to catalog confirmation |
| Cannulation Diameter | Not provided |
| Compatible Guide Wire | Not provided |
| Guide-Wire Diameter | Not provided |
| Bone Thread Geometry | Not provided |
| Thread Pitch | Not provided |
| Thread Depth | Not provided |
| Core Diameter | Not provided |
| Threaded Length | Not provided |
| Locking Head Geometry | Not provided |
| Head Diameter | Not provided |
| Head Height | Not provided |
| Drive Interface | Not provided |
| Tip Geometry | Self-tapping; exact geometry not provided |
| Compatible Locking Plate / Implant | Not provided |
| Compatible Drill Size | Not provided |
| Compatible Screwdriver | Not provided |
| Titanium Grade | Not provided |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
Technical Overview
Product Name: Locking Head Bone Screw, Cannulated Self Tapping Ø 5.0 mm
Product Category: Trauma – Screw
Product Type: Orthopedic Cannulated Locking Head Bone Screw
Head Configuration: Locking Head
Cannulation: Present
Self Tapping: Yes
Self Drilling: Not specified
Nominal Diameter: Ø 5.0 mm
Length Range: 30–90 mm
Length Increment: 5 mm
Total Length Options: 13
Material Options: SS316L and Titanium
Fixation Concept: Guided locking screw fixation within a compatible orthopedic fixation construct
Cannulation Details: Not supplied
Guide-Wire Compatibility: Not supplied
Bone Thread Geometry: Not supplied
Locking Head Geometry: Not supplied
Drive Interface: Not supplied
Compatible Implant System: Not supplied
Specific Titanium Grade: Not supplied
Compatible Instrumentation: Not supplied
Cat. No.: Not supplied
GTIN No.: Not supplied
Product Features
- Orthopedic locking fixation screw.
- Specifically identified as a Locking Head Bone Screw.
- Specifically identified as Cannulated.
- Specifically identified as Self Tapping.
- Nominal diameter of Ø 5.0 mm.
- Available from 30 mm to 90 mm.
- Uses 5 mm length increments.
- Provides 13 length configurations.
- Available in SS316L.
- Available in Titanium.
- Features an axial cannulation according to the product designation.
- Features a threaded bone-engaging shaft.
- Features a manufacturer-defined locking head.
- Features a self-tapping distal configuration.
- Includes a proximal insertion interface.
- Intended for use within a compatible locking fixation system.
- Exact cannulation diameter should be confirmed from technical drawings.
- Exact compatible guide-wire diameter should be confirmed.
- Exact bone-thread pitch should be confirmed.
- Exact core diameter should be confirmed.
- Exact locking-head interface geometry should be confirmed.
- Exact head dimensions should be confirmed.
- Exact drive interface should be confirmed.
- Self-drilling capability is not specified in the supplied product data.
- Exact drilling and insertion requirements should be confirmed from the approved surgical technique.
- Exact compatible locking plate / implant should be confirmed from official system documentation.
- Exact Titanium alloy should be confirmed.
- Individual Cat. No. and GTIN No. should be added when the official product matrix is available.


Reviews