Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread

Cannulated Self-Tapping Orthopedic Screw | Ø 6.0 mm | Partial Thread | Lengths 40–115 mm | 5 mm Increments | SS316L / Titanium

The Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread is an orthopedic fixation screw designed for use within a compatible cannulated fixation system.

According to the supplied product image, the screw has a nominal diameter of 6.0 mm, incorporates a partial-thread configuration, is identified as self tapping, and is available in lengths from 40 mm to 115 mm in 5 mm increments. It is manufactured from either SS316L or Titanium.

The supplied product information identifies:

  • Product Name: Cannulated Screw, Self Tapping
  • Product Type: Cannulated Orthopedic Fixation Screw
  • Nominal Diameter: Ø 6.0 mm
  • Cannulation: Yes
  • Design Feature: Self Tapping
  • Thread Configuration: Partial Thread
  • Length Range: 40–115 mm
  • Length Increment: 5 mm
  • Material Options: SS316L, Titanium
  • Number of Length Options: 16
  • Locking Head: Not specified
  • Self Drilling: Not specified
  • Anatomical Region: Not specified in the supplied image

The exact cannulation diameter, guide-wire diameter, thread pitch, threaded length, core diameter, drive interface, self-tapping tip geometry, compatible implant system, Cat. No., GTIN No., and compatible instrumentation are not provided in the supplied image and should be confirmed from the official technical documentation and Instructions for Use.

Product Explanation

The Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread is an orthopedic fixation screw intended to form part of a compatible guided fixation construct.

A simplified fixation concept can be represented as:

Guide Wire / Prepared Fixation Path → 6.0 mm Cannulated Partial-Thread Screw → Compatible Bone / Fixation Construct

The product combines four supplied characteristics:

Cannulated

Self Tapping

Ø 6.0 mm

Partial Thread

The cannulated designation indicates the presence of an axial lumen intended for use with compatible guide-wire-based instrumentation according to the approved surgical technique.

The partial-thread configuration indicates that only part of the screw shaft carries external bone-engaging threads, while another section remains unthreaded.

The exact threaded-to-unthreaded shaft ratio is not provided in the supplied data.

Product Components and Design

  1. Cannulated Screw Body

The product is specifically identified as:

Cannulated Screw

indicating the presence of an internal axial lumen.

The exact:

  • Cannulation diameter.
  • Guide-wire diameter.
  • Guide-wire compatibility.
  • Cannulation tolerances.
  • Internal lumen geometry.

are not supplied.

The safest technical wording is:

Cannulation: Present — exact internal diameter and guide-wire compatibility not specified

  1. Ø 6.0 mm Nominal Diameter

The product title specifies:

Ø 6.0 mm

as the nominal screw diameter.

The supplied data does not separately define:

  • Major thread diameter.
  • Minor / core diameter.
  • Thread depth.
  • Thread pitch.
  • Thread profile.
  • Dimensional tolerances.

These parameters should be confirmed from the manufacturer’s dimensional drawing.

  1. Partial-Thread Configuration

The product is specifically identified as:

Partial Thread

The supplied image visually shows a threaded distal region and a comparatively smooth unthreaded shaft section.

The exact:

  • Threaded length.
  • Unthreaded shaft length.
  • Thread-to-shaft transition.
  • Thread pitch.
  • Thread depth.

are not provided.

  1. Self-Tapping Design

The screw is specifically identified as:

Self Tapping

indicating a manufacturer-defined self-tapping thread-entry / tip configuration.

The exact:

  • Cutting flute geometry.
  • Tip geometry.
  • Thread-start configuration.
  • Drilling requirements.
  • Need for separate tapping.

are not defined in the supplied image.

  1. Threaded Distal Section

The distal portion incorporates external threads intended for bone engagement within the compatible fixation construct.

The exact:

  • Thread pitch.
  • Thread depth.
  • Thread lead.
  • Core diameter.
  • Thread flank geometry.

should be confirmed from the manufacturer’s technical documentation.

  1. Unthreaded Shaft Section

A substantial portion of the screw shaft appears smooth and unthreaded, consistent with the product’s:

Partial Thread

designation.

The exact unthreaded shaft length may vary by overall screw length and should be confirmed from the official product drawings.

  1. Distal Tip

The supplied image shows a defined distal tip associated with the product’s Self Tapping designation.

However, the source does not state:

Self Drilling

Therefore, self-drilling capability should not be added to the technical specification without official confirmation.

  1. Screw Head and Drive Interface

The supplied image shows a proximal screw head with a central opening consistent with cannulation and an insertion interface.

However, the exact drive type is not specified.

Therefore, the product should not be described as:

Hex / Torx / Star / Stardrive / other

without manufacturer confirmation.

Length Configurations

According to the supplied product information:

Length: 40–115 mm (5 mm Variation)

The available lengths are:

No. Length
1 40 mm
2 45 mm
3 50 mm
4 55 mm
5 60 mm
6 65 mm
7 70 mm
8 75 mm
9 80 mm
10 85 mm
11 90 mm
12 95 mm
13 100 mm
14 105 mm
15 110 mm
16 115 mm

Therefore:

Total Length Configurations: 16

Material Options

According to the supplied product information, the screw is available in:

SS316L

and

Titanium

The exact Titanium grade or alloy is not specified and should be confirmed from the manufacturer’s official material documentation.

Intended Use

The Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread is designed for use as part of a compatible orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.

Potential applications may involve fixation where a 6.0 mm cannulated partial-thread screw is specified by the manufacturer.

The exact anatomical indications, compatible implant systems, guide-wire requirements, insertion technique, and bone-preparation requirements are not supplied in the product image.

Screw selection may depend on factors including:

  • Anatomical location.
  • Bone dimensions.
  • Required screw diameter.
  • Required screw length.
  • Requirement for partial-thread fixation.
  • Bone quality.
  • Required fixation construct.
  • Compatible guide wire.
  • Screw trajectory.
  • Compatible drilling instrumentation.
  • Compatible depth gauge.
  • Compatible screwdriver.
  • Preoperative planning.
  • Intraoperative measurement.

The screw should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

Key Benefits

Cannulated Design

The product is specifically identified as:

Cannulated

indicating an axial lumen intended for use within a compatible guided fixation system.

The exact guide-wire specification should be confirmed from official documentation.

Partial-Thread Configuration

The product is specifically identified as:

Partial Thread

providing a threaded distal region combined with an unthreaded shaft section.

The exact biomechanical effect of this configuration should be confirmed from the manufacturer’s approved documentation.

Self-Tapping Design

The product is specifically identified as:

Self Tapping

providing a manufacturer-defined self-tapping tip / thread-entry configuration.

Ø 6.0 mm Nominal Diameter

The product provides a nominal:

6.0 mm screw diameter

within the compatible orthopedic fixation system.

40–115 mm Length Range

The screw is available from:

40 mm to 115 mm

providing a broad range of lengths.

5 mm Length Increments

The complete supplied range uses:

5 mm increments

for standardized screw-length progression.

16 Length Configurations

The complete available range is:

40 / 45 / 50 / 55 / 60 / 65 / 70 / 75 / 80 / 85 / 90 / 95 / 100 / 105 / 110 / 115 mm

providing:

16 individual length options

Two Material Options

According to the supplied product data, the screw is available in:

SS316L

and

Titanium

Multiple Product Variants

Based strictly on the supplied product information, the family includes:

  • 1 nominal diameter: Ø 6.0 mm
  • 1 cannulated configuration
  • 1 partial-thread configuration
  • 1 self-tapping configuration
  • 16 length options
  • 2 material options: SS316L / Titanium

If every listed length is available in both materials, this could theoretically represent:

16 × 2 = up to 32 basic length × material configurations

The exact commercial matrix should be confirmed from the official Cat. No. / GTIN table.

Technical Specifications

Specification Product Data
Product Name Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread
Product Type Cannulated Orthopedic Fixation Screw
Cannulated Yes
Design Self Tapping
Thread Configuration Partial Thread
Nominal Diameter Ø 6.0 mm
Length Range 40–115 mm
Length Increment 5 mm
Available Lengths 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115 mm
Number of Length Options 16
Materials SS316L, Titanium
Potential Basic Configurations Up to 32, subject to catalog confirmation
Cannulation Diameter Not provided
Compatible Guide Wire Not provided
Guide-Wire Diameter Not provided
Thread Pitch Not provided
Thread Depth Not provided
Core Diameter Not provided
Threaded Length Not provided
Unthreaded Shaft Length Not provided
Drive Interface Not provided
Self Drilling Not specified
Locking Head Not specified
Tip Geometry Self-tapping; exact geometry not provided
Compatible Implant / Plate Not provided
Compatible Instrumentation Not provided
Titanium Grade Not provided
Cat. No. Not provided
GTIN No. Not provided

Technical Overview

Product Name: Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread

Product Type: Orthopedic Cannulated Fixation Screw

Nominal Diameter: Ø 6.0 mm

Cannulation: Present

Self Tapping: Yes

Thread Configuration: Partial Thread

Length Range: 40–115 mm

Length Increment: 5 mm

Total Length Options: 16

Material Options: SS316L and Titanium

Screw Geometry: Cannulated screw with threaded distal region and unthreaded shaft section

Fixation Concept: Guided screw fixation within a compatible orthopedic fixation construct

Self Drilling: Not specified

Locking Head: Not specified

Cannulation Details: Not supplied

Guide-Wire Compatibility: Not supplied

Thread Geometry: Not supplied

Drive Interface: Not supplied

Compatible Implant System: Not supplied

Specific Titanium Grade: Not supplied

Cat. No.: Not supplied

GTIN No.: Not supplied

Product Features

  • Orthopedic cannulated fixation screw.
  • Specifically identified as Self Tapping.
  • Specifically identified as Partial Thread.
  • Nominal diameter of Ø 6.0 mm.
  • Includes an axial cannulation according to the product designation.
  • Features a threaded distal section.
  • Features an unthreaded shaft section.
  • Available from 40 mm to 115 mm.
  • Uses 5 mm length increments.
  • Provides 16 length configurations.
  • Available in SS316L.
  • Available in Titanium.
  • Includes a proximal screw head.
  • Includes a central opening consistent with cannulation.
  • Exact cannulation diameter should be confirmed from technical drawings.
  • Exact guide-wire diameter should be confirmed.
  • Exact thread pitch and thread depth should be confirmed.
  • Exact threaded and unthreaded section lengths should be confirmed.
  • Exact core diameter should be confirmed.
  • Exact head dimensions should be confirmed.
  • Exact drive interface should be confirmed.
  • Self-drilling capability is not specified in the supplied product data.
  • Locking-head configuration is not specified in the supplied product data.
  • Exact insertion technique should be confirmed from the manufacturer’s surgical technique.
  • Exact compatible implant system should be confirmed from official documentation.
  • Exact Titanium alloy should be confirmed.
  • Individual Cat. No. and GTIN No. should be added when the official product matrix is available.
  • Approved indications, contraindications, and insertion technique should be confirmed from the manufacturer’s Instructions for Use (IFU).

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top