Locking Head Bone Cannulated Screw, Self Tapping Ø 7.3 mm – Fully Threaded

Cannulated Self-Tapping Locking Head Bone Screw | Ø 7.3 mm | Fully Threaded | Lengths 40–115 mm | 5 mm Increments | SS316L / Titanium

The Locking Head Bone Cannulated Screw, Self Tapping Ø 7.3 mm – Fully Threaded is an orthopedic fixation screw designed for use within a compatible locking orthopedic fixation system.

According to the supplied product image, the screw has a nominal diameter of 7.3 mm, incorporates a locking head, is cannulated, is identified as self tapping, and has a fully threaded configuration. It is available in lengths from 40 mm to 115 mm in 5 mm increments and is manufactured from either SS316L or Titanium.

The supplied product information identifies:

  • Product Name: Locking Head Bone Cannulated Screw, Self Tapping
  • Product Type: Cannulated Locking Head Bone Screw
  • Nominal Diameter: Ø 7.3 mm
  • Head Configuration: Locking Head
  • Cannulation: Yes
  • Design Feature: Self Tapping
  • Thread Configuration: Fully Threaded
  • Length Range: 40–115 mm
  • Length Increment: 5 mm
  • Material Options: SS316L, Titanium
  • Number of Length Options: 16
  • Self Drilling: Not specified
  • Anatomical Region: Not specified in the supplied image

The exact cannulation diameter, compatible guide-wire diameter, bone-thread pitch, core diameter, locking-head interface, drive geometry, self-tapping tip geometry, compatible locking implant, Cat. No., GTIN No., and compatible instrumentation are not provided and should be confirmed from the official technical documentation and Instructions for Use.

Product Explanation

The Locking Head Bone Cannulated Screw, Self Tapping Ø 7.3 mm – Fully Threaded is an orthopedic fixation screw intended to form part of a compatible guided locking fixation construct.

A simplified fixation concept can be represented as:

Guide Wire / Prepared Fixation Path → Compatible Locking Implant → 7.3 mm Cannulated Locking Head Screw → Locked Fixation Construct

The product combines five principal supplied characteristics:

Locking Head

Cannulated

Self Tapping

Ø 7.3 mm

Fully Threaded

The cannulated configuration indicates the presence of an axial internal lumen intended for use with compatible guided instrumentation.

The locking head indicates compatibility with a manufacturer-defined locking fixation interface.

The fully threaded configuration indicates that external bone-engaging threads extend along essentially the working shaft rather than being limited to a distal section.

Product Components and Design

  1. Locking Head

The product is specifically identified as a:

Locking Head Bone Screw

The proximal head is intended to interface with a compatible locking plate or fixation component.

The supplied image does not specify:

  • Locking-head thread pitch.
  • Locking-head diameter.
  • Locking interface geometry.
  • Fixed-angle characteristics.
  • Variable-angle capability.
  • Compatible plate-hole geometry.

These specifications should be confirmed from the manufacturer’s engineering drawings.

  1. Cannulated Screw Body

The product is specifically identified as:

Cannulated

indicating an internal axial lumen through the screw.

The exact:

  • Cannulation diameter.
  • Guide-wire diameter.
  • Guide-wire compatibility.
  • Cannulation tolerance.
  • Internal lumen geometry.

are not supplied.

The safest technical wording is:

Cannulation: Present — exact internal diameter and guide-wire compatibility not specified

  1. Ø 7.3 mm Nominal Diameter

The product title specifies:

Ø 7.3 mm

as the nominal screw diameter.

The supplied data does not separately define:

  • Major thread diameter.
  • Minor / core diameter.
  • Thread depth.
  • Bone-thread pitch.
  • Thread profile.
  • Dimensional tolerances.

These parameters should be confirmed from the manufacturer’s dimensional drawing.

  1. Fully Threaded Configuration

The source states:

Fully Thread

The standardized technical wording for the catalog should be:

Fully Threaded

The supplied image visually shows threading extending along essentially the complete working shaft.

The exact threaded length for each screw size is not supplied.

  1. Self-Tapping Design

The product is specifically identified as:

Self Tapping

indicating a manufacturer-defined self-tapping distal / thread-entry configuration.

The exact:

  • Cutting flute geometry.
  • Tip configuration.
  • Thread-start geometry.
  • Drilling requirements.
  • Tapping requirements.

are not specified in the supplied image.

  1. Threaded Shaft

The screw visibly incorporates external bone-engaging threads along the shaft.

The exact:

  • Thread pitch.
  • Thread depth.
  • Thread lead.
  • Core diameter.
  • Thread flank geometry.
  • Effective threaded length.

should be confirmed from the manufacturer’s technical drawings.

  1. Distal Tip

The distal tip is associated with the product’s Self Tapping designation.

However, the source does not state:

Self Drilling

Therefore, self-drilling capability should not be added unless separately confirmed.

  1. Drive Interface

The supplied image shows an insertion interface within the proximal screw head.

However, the exact drive type is not specified.

Therefore, the product sheet should not identify the drive as:

Hex / Torx / Star / Stardrive / other

without manufacturer confirmation.

Length Configurations

According to the supplied product information:

Length: 40–115 mm (5 mm Variation)

The available lengths are:

No. Length
1 40 mm
2 45 mm
3 50 mm
4 55 mm
5 60 mm
6 65 mm
7 70 mm
8 75 mm
9 80 mm
10 85 mm
11 90 mm
12 95 mm
13 100 mm
14 105 mm
15 110 mm
16 115 mm

Therefore:

Total Length Configurations: 16

Material Options

According to the supplied product information, the screw is available in:

SS316L

and

Titanium

The exact Titanium alloy or grade is not specified and should be confirmed from official material documentation.

Intended Use

The Locking Head Bone Cannulated Screw, Self Tapping Ø 7.3 mm – Fully Threaded is designed for use as part of a compatible locking orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.

Potential applications may involve fixation where a compatible 7.3 mm cannulated fully threaded locking head screw is specified by the manufacturer.

The exact anatomical indications, compatible implants, guide-wire requirements, screw-placement technique, and preparation requirements are not supplied in the image.

Screw selection may depend on factors including:

  • Anatomical location.
  • Compatible locking implant.
  • Bone dimensions.
  • Bone quality.
  • Required screw diameter.
  • Required screw length.
  • Requirement for a fully threaded configuration.
  • Required fixation construct.
  • Compatible guide wire.
  • Screw trajectory.
  • Compatible drilling instrumentation.
  • Compatible depth gauge.
  • Compatible screwdriver.
  • Preoperative planning.
  • Intraoperative measurement.

The screw should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

Key Benefits

Locking Head Configuration

The product is specifically identified as a:

Locking Head Bone Screw

indicating compatibility with a manufacturer-defined locking fixation interface.

The exact locking-head geometry should be confirmed from official system documentation.

Cannulated Design

The product is specifically identified as:

Cannulated

indicating an axial internal lumen for use within a compatible guided fixation system.

The exact guide-wire specification should be confirmed from manufacturer documentation.

Fully Threaded Configuration

The screw is specifically identified as:

Fully Threaded

providing external bone-engaging threads along essentially the complete working shaft.

Self-Tapping Design

The product is specifically identified as:

Self Tapping

providing a manufacturer-defined self-tapping distal configuration.

Ø 7.3 mm Nominal Diameter

The screw provides a nominal:

7.3 mm diameter

within the compatible fixation system.

40–115 mm Length Range

The screw is available from:

40 mm to 115 mm

providing a broad selection of lengths.

5 mm Length Increments

The complete range uses:

5 mm increments

for standardized length progression.

16 Length Configurations

The complete available range is:

40 / 45 / 50 / 55 / 60 / 65 / 70 / 75 / 80 / 85 / 90 / 95 / 100 / 105 / 110 / 115 mm

providing:

16 individual length options

Two Material Options

According to the supplied data, the screw is available in:

SS316L

and

Titanium

Multiple Product Variants

Based strictly on the supplied information, the family includes:

  • 1 nominal diameter: Ø 7.3 mm
  • 1 locking-head configuration
  • 1 cannulated configuration
  • 1 fully threaded configuration
  • 1 self-tapping configuration
  • 16 length options
  • 2 material options: SS316L / Titanium

If every listed length is available in both materials:

16 × 2 = up to 32 basic length × material configurations

The exact commercial matrix should be confirmed from the official Cat. No. / GTIN table.

Technical Specifications

Specification Product Data
Product Name Locking Head Bone Cannulated Screw, Self Tapping Ø 7.3 mm – Fully Threaded
Product Type Cannulated Locking Head Bone Screw
Head Type Locking Head
Cannulated Yes
Self Tapping Yes
Thread Configuration Fully Threaded
Self Drilling Not specified
Nominal Diameter Ø 7.3 mm
Length Range 40–115 mm
Length Increment 5 mm
Available Lengths 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115 mm
Number of Length Options 16
Materials SS316L, Titanium
Potential Basic Configurations Up to 32, subject to catalog confirmation
Cannulation Diameter Not provided
Compatible Guide Wire Not provided
Guide-Wire Diameter Not provided
Bone Thread Pitch Not provided
Thread Depth Not provided
Core Diameter Not provided
Threaded Length Not provided
Locking Head Geometry Not provided
Head Diameter Not provided
Head Height Not provided
Drive Interface Not provided
Tip Geometry Self-tapping; exact geometry not provided
Compatible Locking Implant Not provided
Compatible Instrumentation Not provided
Titanium Grade Not provided
Cat. No. Not provided
GTIN No. Not provided

Technical Overview

Product Name: Locking Head Bone Cannulated Screw, Self Tapping Ø 7.3 mm – Fully Threaded

Product Type: Orthopedic Cannulated Locking Head Bone Screw

Head Configuration: Locking Head

Cannulation: Present

Self Tapping: Yes

Thread Configuration: Fully Threaded

Self Drilling: Not specified

Nominal Diameter: Ø 7.3 mm

Length Range: 40–115 mm

Length Increment: 5 mm

Total Length Options: 16

Material Options: SS316L and Titanium

Screw Geometry: Cannulated, fully threaded locking head fixation screw

Fixation Concept: Guided locking screw fixation within a compatible orthopedic fixation construct

Cannulation Details: Not supplied

Guide-Wire Compatibility: Not supplied

Thread Geometry: Not supplied

Locking Head Geometry: Not supplied

Drive Interface: Not supplied

Compatible Implant System: Not supplied

Specific Titanium Grade: Not supplied

Cat. No.: Not supplied

GTIN No.: Not supplied

Product Features

  • Orthopedic locking fixation screw.
  • Specifically identified as a Locking Head Bone Screw.
  • Specifically identified as Cannulated.
  • Specifically identified as Self Tapping.
  • Specifically identified as Fully Threaded.
  • Nominal diameter of Ø 7.3 mm.
  • Includes axial cannulation according to the product designation.
  • Features external threading along essentially the complete working shaft.
  • Available from 40 mm to 115 mm.
  • Uses 5 mm length increments.
  • Provides 16 length configurations.
  • Available in SS316L.
  • Available in Titanium.
  • Features a manufacturer-defined locking head.
  • Features a self-tapping distal configuration.
  • Includes a proximal insertion interface.
  • Intended for use within a compatible locking fixation system.
  • Exact cannulation diameter should be confirmed from technical drawings.
  • Exact compatible guide-wire diameter should be confirmed.
  • Exact thread pitch and thread depth should be confirmed.
  • Exact core diameter should be confirmed.
  • Exact locking-head interface geometry should be confirmed.
  • Exact head dimensions should be confirmed.
  • Exact drive interface should be confirmed.
  • Self-drilling capability is not specified in the supplied product data.
  • Exact insertion technique should be confirmed from the manufacturer’s surgical technique.
  • Exact compatible locking implant should be confirmed from official documentation.
  • Exact Titanium alloy should be confirmed.
  • Individual Cat. No. and GTIN No. should be added when the official product matrix is available.
  • Approved indications, contraindications, and insertion technique should be confirmed from the manufacturer’s Instructions for Use (IFU).

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.