Dynamic Hip Screw Ø 12.5 mm

Dynamic Hip Screw | Ø 12.5 mm | Lengths 50–115 mm | 5 mm Increments | SS316L / Titanium

The Dynamic Hip Screw Ø 12.5 mm is an orthopedic fixation screw designed for use within a compatible dynamic hip fixation system.

According to the supplied product image, the screw has a nominal diameter of 12.5 mm and is available in lengths from 50 mm to 115 mm in 5 mm increments. It is manufactured from either SS316L or Titanium.

The supplied product information identifies:

  • Product Name: Dynamic Hip Screw
  • Product Type: Orthopedic Hip Fixation Screw
  • Nominal Diameter: Ø 12.5 mm
  • Length Range: 50–115 mm
  • Length Increment: 5 mm
  • Material Options: SS316L, Titanium
  • Number of Length Options: 14
  • Thread Configuration: Distal threaded section visible; exact specification not provided
  • Cannulated: Not specified
  • Self Tapping: Not specified
  • Self Drilling: Not specified
  • Anatomical Region: Hip / proximal femoral fixation system, based on product designation

The exact thread pitch, thread depth, core diameter, threaded length, proximal interface, compatible barrel/plate dimensions, Cat. No., GTIN No., and compatible instrumentation are not provided in the supplied image and should be confirmed from the official technical documentation and Instructions for Use.

Product Explanation

The Dynamic Hip Screw Ø 12.5 mm is an orthopedic fixation component intended to form part of a compatible dynamic hip fixation construct.

A simplified system relationship can be represented as:

Proximal Femoral Fixation Site → Dynamic Hip Screw → Compatible Barrel / Plate Component → Internal Fixation Construct

The product is specifically identified as a:

Dynamic Hip Screw

with a nominal diameter of:

Ø 12.5 mm

The supplied image shows a long metallic screw body with a threaded distal fixation region and a comparatively smooth proximal shaft.

The exact mechanical relationship between the screw and the compatible plate/barrel system should be confirmed from the manufacturer’s official system documentation.

Product Components and Design

  1. Dynamic Hip Screw Body

The implant consists of an elongated metallic screw body designed for use as part of a compatible dynamic hip fixation system.

The supplied image visually shows:

  • An elongated cylindrical shaft.
  • A threaded distal region.
  • A smoother proximal shaft section.
  • A proximal end configured to interface with another component of the fixation system.

The exact dimensions beyond the nominal diameter and total length are not provided.

  1. Ø 12.5 mm Nominal Diameter

The product title specifies:

Ø 12.5 mm

as the nominal screw diameter.

The supplied product data does not separately define:

  • Major thread diameter.
  • Minor/core diameter.
  • Shaft diameter.
  • Thread depth.
  • Thread pitch.
  • Dimensional tolerances.

These parameters should be confirmed from the manufacturer’s engineering drawings.

  1. Distal Threaded Fixation Region

The supplied image clearly shows a threaded region at one end of the screw.

This represents the bone-engaging portion of the screw within the compatible fixation construct.

However, the exact:

  • Thread pitch.
  • Thread depth.
  • Thread lead.
  • Threaded length.
  • Thread profile.
  • Core diameter.

are not supplied.

  1. Smooth Shaft Section

A substantial central/proximal portion of the screw appears comparatively smooth and unthreaded.

The exact length of the smooth shaft relative to the threaded portion is not provided and may vary by screw length.

  1. Proximal Interface

The proximal end of the screw visually incorporates a distinct interface geometry.

Because the product is identified as a Dynamic Hip Screw, this proximal portion is intended to interact with compatible components within the manufacturer’s fixation system.

However, the exact:

  • Barrel compatibility.
  • Sliding interface geometry.
  • Connection dimensions.
  • Instrument interface.
  • Anti-rotation features.

are not provided in the supplied image.

  1. Screw Tip

The distal fixation region terminates in a defined screw end.

The exact tip geometry and whether the screw is:

Self Tapping

or

Self Drilling

are not specified.

Therefore, neither feature should be added to the technical sheet without confirmation from official product documentation.

  1. Material Options

According to the supplied product data, the screw is available in:

SS316L

and

Titanium

The exact Titanium alloy or grade is not specified and should be confirmed from the manufacturer’s official material specification.

Length Configurations

According to the supplied product information:

Length: 50–115 mm (5 mm Variation)

The available lengths are:

No. Length
1 50 mm
2 55 mm
3 60 mm
4 65 mm
5 70 mm
6 75 mm
7 80 mm
8 85 mm
9 90 mm
10 95 mm
11 100 mm
12 105 mm
13 110 mm
14 115 mm

Therefore:

Total Length Configurations: 14

Intended Use

The Dynamic Hip Screw Ø 12.5 mm is designed for use as part of a compatible dynamic hip fixation system according to the approved indications, surgical technique, and Instructions for Use.

Potential use may involve orthopedic fixation where a compatible Dynamic Hip Screw system is specified by the manufacturer.

The exact fracture indications, anatomical indications, compatible plate/barrel configurations, insertion technique, contraindications, and patient-selection criteria are not provided in the supplied image and should be confirmed from the manufacturer’s official product documentation.

Screw selection may depend on factors including:

  • Proximal femoral anatomy.
  • Required screw length.
  • Required fixation depth.
  • Compatible dynamic hip plate.
  • Compatible barrel size.
  • Bone dimensions.
  • Bone quality.
  • Fixation construct.
  • Screw trajectory.
  • Compatible guide and drilling instrumentation.
  • Compatible depth gauge.
  • Compatible insertion instruments.
  • Preoperative planning.
  • Intraoperative measurement.

The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

Key Benefits

Dedicated Dynamic Hip Fixation Component

The product is specifically identified as a:

Dynamic Hip Screw

indicating its role within a compatible dynamic hip fixation system.

The exact mechanical behavior and compatible construct should be confirmed from official system documentation.

Ø 12.5 mm Nominal Diameter

The screw provides a defined:

12.5 mm nominal diameter

within the compatible fixation system.

Broad Length Range

The product is available from:

50 mm to 115 mm

providing multiple screw-length options within the same product family.

5 mm Length Increments

The complete supplied range uses:

5 mm increments

providing standardized length progression.

14 Length Configurations

The complete available range is:

50 / 55 / 60 / 65 / 70 / 75 / 80 / 85 / 90 / 95 / 100 / 105 / 110 / 115 mm

providing:

14 individual length options

Two Material Options

According to the supplied product information, the screw is available in:

SS316L

and

Titanium

Multiple Product Variants

Based strictly on the supplied product information, the family includes:

  • 1 nominal diameter: Ø 12.5 mm
  • 14 length options
  • 2 material options: SS316L / Titanium

If every listed length is available in both materials, this could theoretically represent:

14 × 2 = up to 28 basic length × material configurations

The exact commercial matrix should be confirmed from the official Cat. No. / GTIN table.

Technical Specifications

Specification Product Data
Product Name Dynamic Hip Screw Ø 12.5 mm
Product Type Orthopedic Hip Fixation Screw
Nominal Diameter Ø 12.5 mm
Length Range 50–115 mm
Length Increment 5 mm
Available Lengths 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115 mm
Number of Length Options 14
Materials SS316L, Titanium
Potential Basic Configurations Up to 28, subject to catalog confirmation
Thread Configuration Distal threaded region visible; exact specification not provided
Thread Pitch Not provided
Thread Depth Not provided
Core Diameter Not provided
Threaded Length Not provided
Smooth Shaft Length Not provided
Proximal Interface Geometry Not provided
Compatible Barrel Not provided
Compatible Dynamic Hip Plate Not provided
Cannulated Not specified
Self Tapping Not specified
Self Drilling Not specified
Compatible Instrumentation Not provided
Titanium Grade Not provided
Cat. No. Not provided
GTIN No. Not provided

Technical Overview

Product Name: Dynamic Hip Screw Ø 12.5 mm

Product Type: Orthopedic Dynamic Hip Fixation Screw

Nominal Diameter: Ø 12.5 mm

Length Range: 50–115 mm

Length Increment: 5 mm

Total Length Options: 14

Material Options: SS316L and Titanium

Screw Geometry: Elongated shaft with distal threaded fixation region

Fixation Concept: Component of a compatible dynamic hip fixation construct

Thread Geometry: Not supplied

Threaded Length: Not supplied

Compatible Barrel / Plate: Not supplied

Cannulated: Not specified

Self Tapping: Not specified

Self Drilling: Not specified

Compatible Instrumentation: Not supplied

Specific Titanium Grade: Not supplied

Cat. No.: Not supplied

GTIN No.: Not supplied

Product Features

  • Orthopedic fixation screw.
  • Specifically identified as a Dynamic Hip Screw.
  • Nominal diameter of Ø 12.5 mm.
  • Available from 50 mm to 115 mm.
  • Uses 5 mm length increments.
  • Provides 14 length configurations.
  • Available in SS316L.
  • Available in Titanium.
  • Features an elongated screw body.
  • Features a distal threaded fixation region.
  • Features a comparatively smooth shaft section.
  • Includes a defined proximal system interface.
  • Intended for use within a compatible Dynamic Hip fixation system.
  • Exact thread pitch and thread depth should be confirmed.
  • Exact core diameter should be confirmed.
  • Exact threaded length should be confirmed.
  • Exact proximal interface geometry should be confirmed.
  • Exact compatible barrel dimensions should be confirmed.
  • Exact compatible plate configurations should be confirmed.
  • Cannulation is not specified in the supplied product data.
  • Self-tapping capability is not specified.
  • Self-drilling capability is not specified.
  • Exact instrumentation should be confirmed from the manufacturer’s surgical technique.
  • Exact Titanium alloy should be confirmed.
  • Individual Cat. No. and GTIN No. should be added when the official product matrix is available.
  • Approved indications, contraindications, and insertion technique should be confirmed from the manufacturer’s Instructions for Use (IFU).