The Gama Nail is intended to be used as part of a compatible orthopedic intramedullary fixation system according to the approved indications, surgical technique, and Instructions for Use. The exact fracture indications, anatomical requirements, laterality requirements, compatible locking screws, instrumentation, and surgical approach should be confirmed from the official technical documentation.
The product is shown with right- and left-sided configurations. Both material variants have a 13 mm diameter. The listed lengths range from 180 mm to 340 mm, with the 260 mm, 280 mm, 300 mm, 320 mm, 360 mm, and 400 mm options absent from the supplied image. Selection of nail length, laterality, material variant, and associated fixation components should be performed according to the applicable anatomy, fracture characteristics, bone dimensions, patient requirements, and approved surgical plan.
According to the provided product information, the product family is identified as:
Product Name as Shown: Gama Nail
The product family has the following specifications shown in the image:
Diameter: 13 mm
Laterality: Right and Left
Material Variants: TIT and Stainless Steel (316L)
Listed Lengths: 180 mm, 200 mm, 220 mm, 240 mm, and 340 mm
Number of Configurations: 5 per laterality-and-material combination; 20 total identified entries
The product name spelling Gama is reproduced as shown in the supplied image. Any standardized product-name spelling should be confirmed from the official technical documentation.
The material notation TIT is also reproduced exactly as shown in the supplied image. Its expanded material designation and applicable material standard should be confirmed from the official technical documentation.
The image legend identifies the black marker with Right and the blue marker with Left. The laterality assignment is reported as shown and must be verified against the official product labeling before use.
Each length, laterality, and material variant is assigned an individual Cat. No. and GTIN No., supporting accurate implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.
Product Explanation
The Gama Nail is an orthopedic intramedullary fixation implant used within a compatible femoral fracture fixation construct. It is positioned within the applicable medullary canal and used with compatible proximal and distal fixation components according to the approved surgical technique and product documentation.
A simplified fixation concept can be represented as:
Proximal Femoral / Compatible Fracture Construct → Gama Nail → Compatible Locking Components → Intramedullary Fixation Construct
Nail diameter, length, laterality, and material variant are selected according to the patient’s anatomy, fracture location and pattern, medullary canal dimensions, required fixation levels, bone quality, and the surgical plan.
Product Components and Design
- Intramedullary Nail Body
The supplied image shows gamma nail components intended for placement within a compatible medullary canal. The nail diameter is identified as 13 mm. The detailed cross-sectional geometry, curvature, wall thickness, and mechanical specifications are not defined in the supplied image.
- Right and Left Configurations
The product family includes right- and left-sided configurations. The image legend uses black and blue markers to identify the two sides. The exact laterality-specific geometry, angle, orientation, and compatibility requirements should be confirmed from the official technical documentation.
- Proximal and Distal Fixation Features
The product illustrations show associated fixation components at the proximal and distal regions of the nail. The exact number, position, dimensions, orientation, and compatibility of the locking holes or screws are not specified in the supplied image.
- Material Variants
The supplied image identifies two material variants:
- TIT, reproduced as shown in the image. The expanded designation should be confirmed from official documentation.
- Stainless Steel (316L).
The material variant must be matched with the applicable laterality, Cat. No., GTIN No., surgical set, and product documentation.
- Diameter Configuration
All listed configurations are identified with a diameter of:
13 mm
- Length-Specific Configurations
Each laterality-and-material combination contains the following five listed length options:
180 / 200 / 220 / 240 / 340 mm
The sequence is not uniformly spaced, and the additional lengths not shown in the image should not be assumed to be available.
Intended Use
The Gama Nail is designed for use within a compatible orthopedic intramedullary fixation system according to the approved indications, surgical technique, and Instructions for Use.
The supplied image alone does not define the complete clinical indication, fracture classification, patient population, associated locking screws, laterality-specific surgical approach, contraindications, or material-selection criteria. These details should be confirmed from the official product documentation and applicable regulatory information.
Nail selection and use depend on factors including:
- Applicable anatomy.
- Fracture location and pattern.
- Medullary canal dimensions.
- Required nail diameter.
- Required nail length.
- Right- or left-sided anatomical requirements.
- Proximal and distal fixation requirements.
- Material compatibility and applicable product requirements.
- Bone quality.
- Compatible locking screws and instrumentation.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Features
13 mm Nail Diameter
All listed configurations are identified with a diameter of:
13 mm
Right and Left Options
The supplied image identifies two laterality options:
- Right, represented by the black legend marker.
- Left, represented by the blue legend marker.
The laterality assignment should be confirmed from the official product labeling and technical documentation.
Two Material Variants
The supplied image presents two variants:
- TIT, as written in the image.
- Stainless Steel (316L).
The expanded material designation for TIT should be confirmed from official technical documentation.
Five Listed Length Configurations
Each laterality-and-material combination includes:
180 mm, 200 mm, 220 mm, 240 mm, and 340 mm
The 260 mm, 280 mm, 300 mm, 320 mm, 360 mm, and 400 mm lengths are not shown in the supplied image.
Gama Nail Design
The product is identified as a Gama Nail and is shown with associated proximal and distal fixation components in a compatible intramedullary fixation concept.
20 Identified Product Entries
The image presents five listed lengths for each of two lateralities and two material variants, resulting in:
20 identified length-, laterality-, and material-specific entries
Product Traceability
Each length, laterality, and material variant has an individual Cat. No. and GTIN No. to support implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.
Technical Specifications — TIT Variant
| Laterality | Material | Diameter | Length | Cat. No. | GTIN No. |
| Right | TIT | 13 mm | 180 mm | AMS 818.013.018T | 6221361000629 |
| Right | TIT | 13 mm | 200 mm | AMS 818.013.020T | 6221361000643 |
| Right | TIT | 13 mm | 220 mm | AMS 818.013.022T | 6221361000667 |
| Right | TIT | 13 mm | 240 mm | AMS 818.013.024T | 6221361000681 |
| Right | TIT | 13 mm | 340 mm | AMS 818.013.034T | 6221361045897 |
| Left | TIT | 13 mm | 180 mm | AMS 818.113.018T | 6221361046184 |
| Left | TIT | 13 mm | 200 mm | AMS 818.113.020T | 6221361046191 |
| Left | TIT | 13 mm | 220 mm | AMS 818.113.022T | 6221361046207 |
| Left | TIT | 13 mm | 240 mm | AMS 818.113.024T | 6221361046214 |
| Left | TIT | 13 mm | 340 mm | AMS 818.113.034T | 6221361046221 |
Technical Specifications — Stainless Steel (316L) Variant
| Laterality | Material | Diameter | Length | Cat. No. | GTIN No. |
| Right | Stainless Steel (316L) | 13 mm | 180 mm | AMS 818.013.018S | 6221361000438 |
| Right | Stainless Steel (316L) | 13 mm | 200 mm | AMS 818.013.020S | 6221361000452 |
| Right | Stainless Steel (316L) | 13 mm | 220 mm | AMS 818.013.022S | 6221361000476 |
| Right | Stainless Steel (316L) | 13 mm | 240 mm | AMS 818.013.024S | 6221361000490 |
| Right | Stainless Steel (316L) | 13 mm | 340 mm | AMS 818.013.034S | 6221361046658 |
| Left | Stainless Steel (316L) | 13 mm | 180 mm | AMS 818.113.018S | 6221361046955 |
| Left | Stainless Steel (316L) | 13 mm | 200 mm | AMS 818.113.020S | 6221361046962 |
| Left | Stainless Steel (316L) | 13 mm | 220 mm | AMS 818.113.022S | 6221361046979 |
| Left | Stainless Steel (316L) | 13 mm | 240 mm | AMS 818.113.024S | 6221361046986 |
| Left | Stainless Steel (316L) | 13 mm | 340 mm | AMS 818.113.034S | 6221361046993 |
Laterality and Variant Comparison
| Specification | Right | Left |
| Diameter | 13 mm | 13 mm |
| Available materials | TIT and Stainless Steel (316L) | TIT and Stainless Steel (316L) |
| Listed lengths | 180, 200, 220, 240, and 340 mm | 180, 200, 220, 240, and 340 mm |
| Number of entries | 10 | 10 |
| Cat. No. family shown | AMS 818.013.xxx | AMS 818.113.xxx |
| GTIN assignment | Individual GTIN for each length and material | Individual GTIN for each length and material |
| Specification | TIT Variant | Stainless Steel Variant |
| Diameter | 13 mm | 13 mm |
| Laterality options | Right and Left | Right and Left |
| Listed lengths | 180, 200, 220, 240, and 340 mm | 180, 200, 220, 240, and 340 mm |
| Number of entries | 10 | 10 |
| Cat. No. suffix shown | T | S |
| GTIN assignment | Individual GTIN for each length and side | Individual GTIN for each length and side |
The tables above summarize only the information visible in the supplied image. The laterality assignment, Cat. No. suffixes, product-name spelling, and material notation are reported as shown and should be confirmed against the official product documentation.
Technical Overview
Product Name as Shown: Gama Nail
Product Type: Intramedullary Orthopedic Fixation Implant
Product Category: Gama Nail
Diameter: 13 mm
Laterality: Right and Left
Material Variants: TIT and Stainless Steel (316L)
Listed Lengths: 180 mm, 200 mm, 220 mm, 240 mm, and 340 mm
Number of Configurations: 5 lengths × 2 sides × 2 materials = 20 identified entries
Design: Intramedullary Nail with Proximal and Distal Fixation Components
Fixation Concept: Gamma Nail Intramedullary Fixation
Anatomical Application: Compatible femoral fixation procedures; confirm the specific application from official documentation
Identification: Individual Cat. No. and GTIN No. for each length, laterality, and material combination
Product Features
- Gama Nail orthopedic intramedullary fixation design as identified in the supplied image.
- 13 mm diameter for all displayed configurations.
- Right and Left laterality options.
- TIT material notation shown for one variant.
- Stainless Steel (316L) identified for the second variant.
- Available in five listed lengths: 180 mm, 200 mm, 220 mm, 240 mm, and 340 mm.
- The 260 mm, 280 mm, 300 mm, 320 mm, 360 mm, and 400 mm lengths are not shown in the supplied image.
- Ten identified entries per laterality.
- Ten identified entries per material variant.
- 20 identified length-, laterality-, and material-specific entries in total.
- Proximal and distal fixation components shown in the product illustrations.
- Individual Cat. No. for each length, side, and material variant.
- Individual GTIN No. for each configuration.
- Supports implant identification, traceability, procurement, and inventory management.


Reviews