,

Interference Screw [Titanium]

Titanium Interference Screw | Diameters 7–9 mm | Lengths 20–40 mm

The Interference Screw is a titanium orthopedic fixation implant designed for compatible interference fixation procedures. According to the supplied product image, it is available in three diameter configurations—7 mm, 8 mm, and 9 mm—and five length configurations from 20 mm to 40 mm, providing a total of 15 product configurations.

 

  • Manufactured from Titanium according to the provided product data.
  • Interference Screw design intended for compatible orthopedic fixation procedures.
  • Available in 7 mm, 8 mm, and 9 mm diameter options.
  • Available in 20 mm, 25 mm, 30 mm, 35 mm, and 40 mm length options.
  • Each diameter-and-length combination has an individual Cat. No. and GTIN No. to support implant identification, traceability, procurement, and inventory management.

The Interference Screw [Titanium] is a component of a compatible orthopedic fixation system. It is designed to be inserted into prepared bone according to the approved indications, surgical technique, and Instructions for Use.

 

The product features a threaded screw geometry intended to provide fixation within bone when used with compatible surgical techniques and associated implants. The screw diameter and length are selected according to the applicable anatomy, prepared bone dimensions, fixation requirements, and surgical plan.

 

According to the provided product information, the screw material is:

 

Material: Titanium

 

The product family is identified as:

 

Product Name: Interference Screw

 

The screw is available in the following configurations:

 

  • Diameters: 7 mm, 8 mm, and 9 mm.
  • Lengths: 20 mm, 25 mm, 30 mm, 35 mm, and 40 mm.
  • Total configurations: 15.

 

Each diameter-and-length combination is assigned an individual Cat. No. and GTIN No., supporting accurate implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.

 

 

 

Product Explanation

The Interference Screw is an orthopedic implant used as part of a compatible fixation construct. It is placed into prepared bone to provide interference fixation in accordance with the approved surgical technique and product documentation.

 

A simplified fixation concept can be represented as:

 

Prepared Bone / Compatible Tissue Construct → Interference Screw → Orthopedic Fixation Construct

 

Screw diameter and length are selected according to the patient’s anatomy, the prepared bone dimensions, the targeted fixation site, the required fixation characteristics, and the surgical plan.

 

 

 

Product Components and Design

  1. Titanium Screw Body

The main structural body of the implant is manufactured from Titanium, according to the supplied product data. It functions as the primary fixation component inserted into the prepared anatomical site.

 

  1. Threaded Fixation Profile

The screw incorporates a continuous external thread profile intended to engage the surrounding bone and provide fixation when used according to the approved surgical technique.

 

  1. Screw Tip and Insertion Geometry

The product has a tapered screw profile with an insertion end designed to support placement into the prepared fixation site. The specific tip geometry, insertion interface, and driver compatibility are not defined in the supplied table and should be confirmed from the official technical documentation.

 

  1. Diameter-Specific Configurations

The product is available in three diameter options:

 

7 mm / 8 mm / 9 mm

 

  1. Length-Specific Configurations

Each diameter is available in five length options:

 

20 / 25 / 30 / 35 / 40 mm

 

This provides multiple options for implant selection.

 

 

 

Intended Use

The Interference Screw is designed for use within compatible orthopedic fixation systems, according to the approved indications, surgical technique, and Instructions for Use.

 

Potential applications, when included within the approved indications, may include interference fixation in prepared bone during appropriate orthopedic procedures. The specific anatomical application, tissue construct, surgical indication, and compatible instrumentation should be confirmed from the official product documentation.

 

Screw selection depends on factors including:

 

  • Anatomical location.
  • Prepared bone dimensions.
  • Required screw diameter.
  • Required screw length.
  • Fixation site.
  • Bone quality.
  • Compatible implant and instrumentation selection.
  • Preoperative planning.
  • Intraoperative assessment.

 

The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

 

 

 

Key Benefits

Titanium Implant Material

The product is specified as:

 

Material: Titanium

 

according to the supplied catalog image.

 

Multiple Diameter Options

The implant is available in three diameter configurations:

 

7 mm, 8 mm, and 9 mm

 

providing options for different prepared bone dimensions and fixation requirements.

 

Multiple Length Options

The product is available in five length configurations:

 

20 mm, 25 mm, 30 mm, 35 mm, and 40 mm

 

allowing selection according to the required fixation depth and surgical plan.

 

Threaded Fixation Design

The interference screw incorporates a threaded profile intended to support fixation within prepared bone when used with the compatible surgical technique.

 

15 Product Configurations

The product family includes:

 

15 different diameter-and-length configurations

 

comprising three diameters and five lengths.

 

Product Traceability

Each configuration has an individual Cat. No. and GTIN No. to support:

 

  • Implant identification.
  • Product traceability.
  • Surgical set preparation.
  • Inventory management.
  • Stock control.

 

 

 

Technical Specifications

Diameter Length Cat. No. GTIN No.
7 mm 20 mm AMS 521.007.020T 6221361012431
7 mm 25 mm AMS 521.007.025T 6221361012448
7 mm 30 mm AMS 521.007.030T 6221361012455
7 mm 35 mm AMS 521.007.035T 6221361012462
7 mm 40 mm AMS 521.007.040T 6221361012479
8 mm 20 mm AMS 521.008.020T 6221361012486
8 mm 25 mm AMS 521.008.025T 6221361012493
8 mm 30 mm AMS 521.008.030T 6221361012509
8 mm 35 mm AMS 521.008.035T 6221361012516
8 mm 40 mm AMS 521.008.040T 6221361012523
9 mm 20 mm AMS 521.009.020T 6221361012530
9 mm 25 mm AMS 521.009.025T 6221361012547
9 mm 30 mm AMS 521.009.030T 6221361012554
9 mm 35 mm AMS 521.009.035T 6221361012561
9 mm 40 mm AMS 521.009.040T 6221361012578

 

 

Technical Overview

Product Name: Interference Screw
Material: Titanium
Product Type: Titanium Interference Screw
Product Category: Orthopedic Fixation Implant
Diameter Options: 7 mm, 8 mm, and 9 mm
Length Options: 20–40 mm
Length Increment: 5 mm
Number of Configurations: 15
Design: Threaded Interference Screw
Fixation Concept: Interference Fixation
Anatomical Application: Compatible orthopedic fixation procedures
Identification: Individual Cat. No. and GTIN No. for each diameter-and-length configuration

 

 

 

Product Features

  • Titanium Interference Screw design.
  • Manufactured from Titanium according to the catalog image.
  • Threaded external fixation profile.
  • Tapered screw geometry.
  • Available in 7 mm, 8 mm, and 9 mm diameters.
  • Available in 20 mm, 25 mm, 30 mm, 35 mm, and 40 mm lengths.
  • Five-millimeter length increments.
  • Available in 15 diameter-and-length configurations.
  • Designed for compatible orthopedic fixation systems.
  • Supports implant selection according to anatomical and surgical requirements.
  • Individual Cat. No. for each configuration.
  • Individual GTIN No. for each configuration.
  • Supports implant identification, traceability, procurement, and inventory management.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top