Locking Head Bone Cannulated Screw, Self Drilling & Self Tapping Ø 3.7 mm

Cannulated Locking Head Bone Screw | Self Drilling & Self Tapping | Ø 3.7 mm | Lengths 20–90 mm | 2 mm Increments | SS316L / Titanium

The Locking Head Bone Cannulated Screw, Self Drilling & Self Tapping Ø 3.7 mm is an orthopedic fixation screw designed for use within a compatible locking orthopedic fixation system.

According to the supplied product image, the screw has a nominal diameter of 3.7 mm and is available in lengths from 20 mm to 90 mm, increasing in 2 mm increments. The screw is manufactured from either SS316L or Titanium.

The supplied product information identifies:

  • Product Name: Locking Head Bone Cannulated Screw, Self Drilling & Self Tapping
  • Product Category: Trauma – Screw
  • Product Type: Cannulated Locking Head Bone Screw
  • Nominal Diameter: Ø 3.7 mm
  • Head Configuration: Locking Head
  • Cannulation: Yes, according to product designation
  • Design Feature: Self Drilling
  • Design Feature: Self Tapping
  • Length Range: 20–90 mm
  • Length Increment: 2 mm
  • Material Options: SS316L, Titanium
  • Number of Length Options: 36

Based on the stated range and increment, the product family includes:

20 / 22 / 24 / 26 / 28 / 30 / 32 / 34 / 36 / 38 / 40 / 42 / 44 / 46 / 48 / 50 / 52 / 54 / 56 / 58 / 60 / 62 / 64 / 66 / 68 / 70 / 72 / 74 / 76 / 78 / 80 / 82 / 84 / 86 / 88 / 90 mm

The exact cannulation diameter, compatible guide-wire diameter, bone-thread pitch, core diameter, locking-head interface, drive interface, drilling-tip geometry, self-tapping flute geometry, compatible plate-hole design, Cat. No., GTIN No., and compatible instrumentation are not provided in the supplied image and should be confirmed from the official technical documentation and Instructions for Use.

Product Explanation

The Locking Head Bone Cannulated Screw, Self Drilling & Self Tapping Ø 3.7 mm is an orthopedic fixation screw intended to form part of a compatible locking fixation construct.

A simplified fixation concept can be represented as:

Guide Wire / Prepared Fixation Path → Cannulated 3.7 mm Screw → Compatible Locking Plate / Fixation Component → Locked Internal Fixation Construct

The product combines several defined design characteristics:

Locking Head

Cannulated

Self Drilling

Self Tapping

Ø 3.7 mm nominal diameter

The cannulated designation indicates that the screw incorporates a central lumen intended for use with compatible system components according to the approved surgical technique.

The exact guide-wire size and cannulation diameter are not stated in the supplied image and should not be assumed.

Product Components and Design

  1. Locking Head

The product is specifically identified as a:

Locking Head Bone Screw

The proximal screw head is intended to interface with a compatible manufacturer-defined locking fixation system.

The supplied data does not define:

  • Locking-head thread pitch.
  • Head-thread diameter.
  • Locking interface geometry.
  • Fixed-angle characteristics.
  • Variable-angle capability.
  • Compatible plate-hole geometry.

These specifications should be confirmed from the manufacturer’s technical drawings.

  1. Cannulated Screw Body

The product is specifically identified as:

Cannulated

indicating the presence of an internal axial lumen.

The exact:

  • Cannulation diameter.
  • Guide-wire compatibility.
  • Guide-wire diameter.
  • Cannulation tolerance.
  • Lumen geometry.

are not provided in the supplied product data.

Therefore, the safest technical wording is:

Cannulation: Present — exact dimensions and guide-wire compatibility not specified

  1. Ø 3.7 mm Nominal Diameter

The product title specifies:

Ø 3.7 mm

as the nominal screw diameter.

The supplied image does not separately provide:

  • Major thread diameter.
  • Minor / core diameter.
  • Thread depth.
  • Thread pitch.
  • Thread profile.
  • Dimensional tolerances.

These parameters should be obtained from the official dimensional drawing.

  1. Self-Drilling Design

The product is specifically identified as:

Self Drilling

This indicates a manufacturer-defined distal geometry intended to provide drilling capability within the approved surgical technique.

The supplied data does not define:

  • Drilling-tip geometry.
  • Cutting-edge configuration.
  • Tip angle.
  • Required guide-wire preparation.
  • Situations where pre-drilling may still be required.

These characteristics should therefore be confirmed from the official surgical technique.

  1. Self-Tapping Design

The product is also specifically identified as:

Self Tapping

indicating a manufacturer-defined thread-entry / cutting configuration.

The exact:

  • Cutting flute geometry.
  • Number of cutting features.
  • Thread-start design.
  • Tapping requirements.

are not stated in the supplied product information.

  1. Threaded Shaft

The supplied product image visibly shows a threaded screw shaft.

The exact:

  • Thread pitch.
  • Thread depth.
  • Thread lead.
  • Threaded length.
  • Core diameter.
  • Thread profile.

are not provided and should be confirmed from the manufacturer’s technical specifications.

  1. Distal Tip

The distal end is associated with the screw’s:

Self Drilling & Self Tapping

designation.

The exact tip geometry should not be determined solely from the image.

The manufacturer’s engineering drawing and surgical technique should be used to define its cutting and drilling characteristics.

  1. Drive Interface

The supplied image shows an insertion interface within the proximal screw head.

However, the exact drive type is not specified.

Therefore, the product sheet should not identify it as:

Hex / Torx / Star / Stardrive / other

without official confirmation.

Length Configurations

According to the supplied product information:

Length: 20–90 mm (2 mm Variation)

This provides:

36 individual lengths

as follows:

No. Length
1 20 mm
2 22 mm
3 24 mm
4 26 mm
5 28 mm
6 30 mm
7 32 mm
8 34 mm
9 36 mm
10 38 mm
11 40 mm
12 42 mm
13 44 mm
14 46 mm
15 48 mm
16 50 mm
17 52 mm
18 54 mm
19 56 mm
20 58 mm
21 60 mm
22 62 mm
23 64 mm
24 66 mm
25 68 mm
26 70 mm
27 72 mm
28 74 mm
29 76 mm
30 78 mm
31 80 mm
32 82 mm
33 84 mm
34 86 mm
35 88 mm
36 90 mm

Material Options

According to the supplied product data, the screw is available in:

SS316L

and

Titanium

The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the manufacturer’s official material documentation.

Intended Use

The Locking Head Bone Cannulated Screw, Self Drilling & Self Tapping Ø 3.7 mm is designed for use as part of a compatible orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.

Potential applications may involve fixation where a compatible 3.7 mm cannulated locking head screw is specified by the manufacturer.

The exact anatomical indications, compatible plates or fixation components, guide-wire requirements, drilling technique, and screw-placement procedure are not supplied in the image and should be confirmed from the official product documentation.

Screw selection may depend on factors including:

  • Anatomical location.
  • Compatible locking implant.
  • Required screw diameter.
  • Required screw length.
  • Bone dimensions.
  • Bone quality.
  • Required fixation construct.
  • Compatible guide wire.
  • Screw trajectory.
  • Compatible drill / insertion instrumentation.
  • Compatible depth gauge.
  • Compatible screwdriver.
  • Preoperative planning.
  • Intraoperative measurement.

The screw should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

Key Benefits

Cannulated Design

The product is specifically identified as:

Cannulated

indicating an internal lumen for use within a compatible guided fixation system.

The exact guide-wire specification should be confirmed from the manufacturer’s documentation.

Locking Head Configuration

The screw is specifically identified as a:

Locking Head Bone Screw

indicating compatibility with a manufacturer-defined locking fixation interface.

The exact locking-head geometry should be confirmed from the official system documentation.

Self-Drilling Design

The product is specifically identified as:

Self Drilling

providing a manufacturer-defined drilling-tip configuration.

The exact drilling technique should be confirmed from the approved surgical technique.

Self-Tapping Design

The product is also specifically identified as:

Self Tapping

providing a defined self-tapping thread-entry configuration.

Ø 3.7 mm Nominal Diameter

The product provides a nominal:

3.7 mm screw diameter

within the compatible fixation system.

Wide Length Range

The product is available from:

20 mm to 90 mm

providing a broad range of screw lengths.

2 mm Length Increments

The complete range uses:

2 mm increments

allowing closely spaced screw-length selection.

36 Length Configurations

The range from:

20–90 mm

in:

2 mm increments

provides:

36 individual screw-length configurations

Two Material Options

According to the supplied product information, the screw is available in:

SS316L

and

Titanium

Multiple Product Variants

Based strictly on the supplied information, the product family includes:

  • 1 nominal diameter: Ø 3.7 mm
  • 1 cannulated configuration
  • 1 locking-head configuration
  • Self-drilling design
  • Self-tapping design
  • 36 length options
  • 2 material options: SS316L / Titanium

If every listed length is available in both materials, this could theoretically represent:

36 × 2 = up to 72 basic length × material configurations

The exact commercial matrix should be confirmed from the official Cat. No. / GTIN table.

Technical Specifications

Specification Product Data
Product Name Locking Head Bone Cannulated Screw, Self Drilling & Self Tapping Ø 3.7 mm
Product Category Trauma – Screw
Product Type Cannulated Locking Head Bone Screw
Head Type Locking Head
Cannulated Yes
Self Drilling Yes
Self Tapping Yes
Nominal Diameter Ø 3.7 mm
Length Range 20–90 mm
Length Increment 2 mm
Number of Length Options 36
Materials SS316L, Titanium
Potential Basic Configurations Up to 72, subject to catalog confirmation
Cannulation Diameter Not provided
Compatible Guide Wire Not provided
Guide-Wire Diameter Not provided
Bone Thread Geometry Not provided
Thread Pitch Not provided
Core Diameter Not provided
Threaded Length Not provided
Locking Head Geometry Not provided
Head Diameter Not provided
Head Height Not provided
Drive Interface Not provided
Self-Drilling Tip Geometry Not provided
Compatible Locking Implant Not provided
Compatible Drill / Instrumentation Not provided
Compatible Screwdriver Not provided
Titanium Grade Not provided
Cat. No. Not provided
GTIN No. Not provided

Technical Overview

Product Name: Locking Head Bone Cannulated Screw, Self Drilling & Self Tapping Ø 3.7 mm

Product Category: Trauma – Screw

Product Type: Orthopedic Cannulated Locking Head Screw

Head Configuration: Locking Head

Cannulated: Yes

Self Drilling: Yes

Self Tapping: Yes

Nominal Diameter: Ø 3.7 mm

Length Range: 20–90 mm

Length Increment: 2 mm

Total Length Options: 36

Material Options: SS316L and Titanium

Fixation Concept: Guided screw fixation within a compatible locking orthopedic fixation construct

Cannulation Details: Not supplied

Guide-Wire Compatibility: Not supplied

Bone Thread Geometry: Not supplied

Locking Head Geometry: Not supplied

Head / Drive Geometry: Not supplied

Compatible Implant System: Not supplied

Specific Titanium Grade: Not supplied

Compatible Instrumentation: Not supplied

Cat. No.: Not supplied

GTIN No.: Not supplied

Product Features

  • Orthopedic locking fixation screw.
  • Specifically identified as a Cannulated Screw.
  • Specifically identified as a Locking Head Bone Screw.
  • Specifically identified as Self Drilling.
  • Specifically identified as Self Tapping.
  • Nominal diameter of Ø 3.7 mm.
  • Available from 20 mm to 90 mm.
  • Uses 2 mm length increments throughout the complete range.
  • Provides 36 length configurations.
  • Available in SS316L.
  • Available in Titanium.
  • Features a threaded bone-engaging shaft.
  • Features a manufacturer-defined locking head.
  • Includes an axial cannulation according to the product designation.
  • Features a manufacturer-defined self-drilling distal configuration.
  • Features a self-tapping thread-entry configuration.
  • Includes a proximal insertion interface.
  • Intended for use within a compatible locking fixation system.
  • Exact cannulation diameter should be confirmed from technical drawings.
  • Exact guide-wire diameter should be confirmed from the manufacturer’s system documentation.
  • Exact bone-thread pitch and core diameter should be confirmed.
  • Exact locking-head interface geometry should be confirmed.
  • Exact head dimensions should be confirmed.
  • Exact drive interface should be confirmed.
  • Exact self-drilling tip geometry should be confirmed.
  • Exact surgical preparation requirements should be confirmed from the surgical technique.
  • Exact compatible plate / fixation system should be confirmed from official documentation.
  • Exact Titanium alloy should be confirmed.
  • Individual Cat. No. and GTIN No. should be added when the official product matrix is available.
  • Approved indications, contraindications, and insertion technique should be confirmed from the manufacturer’s Instructions for Use (IFU).

 

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top