Locking Head Bone Screw, Self Tapping Ø 2.4 mm

Self-Tapping Locking Head Bone Screw | Ø 2.4 mm | Lengths 10–30 mm | 2 mm Increments | SS316L / Titanium

The Locking Head Bone Screw, Self Tapping Ø 2.4 mm is an orthopedic fixation screw designed for use within a compatible locking plate fixation system.

According to the supplied product image, the screw has a nominal diameter of 2.4 mm and is available in lengths from 10 mm to 30 mm, increasing in 2 mm increments. The screw is manufactured from either SS316L or Titanium.

The supplied product information identifies:

  • Product Name: Locking Head Bone Screw, Self Tapping
  • Product Category: Trauma – Tibia
  • Product Type: Locking Head Bone Screw
  • Nominal Diameter: Ø 2.4 mm
  • Length Range: 10–30 mm
  • Length Increment: 2 mm
  • Material Options: SS316L, Titanium
  • Design Feature: Self Tapping
  • Head Configuration: Locking Head
  • Number of Length Options: 11

Based on the specified range and increment, the available lengths are:

10 / 12 / 14 / 16 / 18 / 20 / 22 / 24 / 26 / 28 / 30 mm

The exact thread pitch, core diameter, head-thread geometry, locking interface, drive interface, self-tapping flute geometry, compatible plate holes, drilling requirements, Cat. No., GTIN No., and compatible instrumentation are not provided in the supplied image and should be confirmed from the official technical documentation and Instructions for Use.

Product Explanation

The Locking Head Bone Screw, Self Tapping Ø 2.4 mm is an orthopedic screw intended to form part of a compatible locking plate-and-screw fixation construct.

A simplified fixation concept can be represented as:

Prepared Bone → Compatible Locking Plate → 2.4 mm Locking Head Screw → Locked Plate–Screw Construct

The product combines three principal characteristics:

Locking Head

Self Tapping

Ø 2.4 mm nominal diameter

The locking-head configuration distinguishes this product from a conventional non-locking screw by indicating compatibility with a manufacturer-defined locking interface.

The exact mechanism by which the screw head locks into the plate—such as specific head threading, locking geometry, or another interface—is not defined in the supplied image and should be confirmed from the manufacturer’s technical documentation.

Product Components and Design

  1. Locking Head

The product is specifically identified as a:

Locking Head Bone Screw

The supplied image visually shows a structured proximal head region consistent with the locking-head designation.

Within a compatible fixation system, the screw head is intended to interface with an appropriate plate hole according to the manufacturer’s approved design.

However, the supplied image does not define:

  • Head thread pitch.
  • Head thread diameter.
  • Locking interface geometry.
  • Locking angle.
  • Variable-angle capability.
  • Compatible plate-hole specification.

These characteristics should therefore be confirmed from the manufacturer’s engineering drawings.

  1. Ø 2.4 mm Screw Body

The product title specifies:

Ø 2.4 mm

as the nominal screw diameter.

The exact dimensional definition of this value—including whether it corresponds to the major thread diameter or another manufacturer-defined diameter—should be confirmed from the official technical drawing.

The supplied data does not separately specify:

  • Core diameter.
  • Minor diameter.
  • Thread depth.
  • Thread pitch.
  • Thread profile.
  1. Self-Tapping Design

The product is specifically identified as:

Self Tapping

indicating a manufacturer-defined self-tapping screw configuration.

The exact:

  • Cutting flute geometry.
  • Tip design.
  • Thread-start geometry.
  • Drilling requirements.
  • Whether pre-tapping is required in specific situations.

are not defined in the supplied image.

These details should be confirmed from the approved surgical technique.

  1. Threaded Shaft

The supplied product image shows a threaded shaft extending along a substantial portion of the screw body.

The thread is intended to provide engagement within compatible bone according to the approved fixation technique.

The exact:

  • Thread pitch.
  • Thread depth.
  • Threaded length.
  • Lead.
  • Thread flank profile.

are not provided in the supplied data.

  1. Screw Tip

The distal end of the screw incorporates a defined tip associated with the product’s Self Tapping designation.

However, the exact tip angle, cutting flute geometry, and penetration characteristics should not be determined from the image alone.

  1. Drive Interface

The supplied image shows an insertion interface within the proximal screw head.

However, the exact drive geometry is not specified.

Therefore, the product sheet should not identify it as:

Hex / Torx / Star / Stardrive / other

without official confirmation.

The compatible screwdriver should be obtained from the manufacturer’s system documentation.

Length Configurations

According to the supplied product information:

Length: 10–30 mm (2 mm Variation)

This provides the following configurations:

No. Length
1 10 mm
2 12 mm
3 14 mm
4 16 mm
5 18 mm
6 20 mm
7 22 mm
8 24 mm
9 26 mm
10 28 mm
11 30 mm

Therefore, the product family includes:

11 length configurations

for the supplied Ø 2.4 mm locking head screw.

Material Options

According to the supplied product data, the screw is available in:

SS316L

and

Titanium

The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the manufacturer’s official material documentation.

Intended Use

The Locking Head Bone Screw, Self Tapping Ø 2.4 mm is designed for use as part of a compatible locking orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.

The supplied catalog places the product under:

Trauma – Tibia

However, the exact approved anatomical applications and compatible plates should be confirmed from the manufacturer’s official system documentation.

Potential use may involve fixation through compatible locking plate holes where a 2.4 mm locking head screw is specified.

Screw selection may depend on factors including:

  • Anatomical location.
  • Compatible locking plate.
  • Plate-hole specification.
  • Bone dimensions.
  • Required screw diameter.
  • Required screw length.
  • Bone quality.
  • Required fixation construct.
  • Screw trajectory.
  • Compatible drill.
  • Compatible depth gauge.
  • Compatible screwdriver.
  • Preoperative planning.
  • Intraoperative measurement.

The screw should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

Key Benefits

Locking Head Configuration

The screw is specifically identified as a:

Locking Head Bone Screw

indicating compatibility with a manufacturer-defined locking plate interface.

The exact locking mechanism should be confirmed from the manufacturer’s technical documentation.

Self-Tapping Design

The product is specifically identified as:

Self Tapping

providing a defined screw-tip / thread-entry configuration within the screw family.

Ø 2.4 mm Nominal Diameter

The product provides a nominal:

2.4 mm screw diameter

within the compatible orthopedic fixation system.

2 mm Length Increments

The screw lengths increase in:

2 mm increments

throughout the supplied range.

11 Length Configurations

The available lengths are:

10 / 12 / 14 / 16 / 18 / 20 / 22 / 24 / 26 / 28 / 30 mm

providing 11 individual screw-length options.

Two Material Options

According to the supplied product information, the screw is available in:

SS316L

and

Titanium

Multiple Product Variants

Based strictly on the supplied information, the product family includes:

  • 1 nominal diameter: Ø 2.4 mm
  • 1 locking-head configuration
  • 11 length options
  • 2 material options: SS316L / Titanium

If every listed length is available in both materials, this could theoretically represent:

11 × 2 = up to 22 basic length × material configurations

The exact commercial matrix should be confirmed from the official Cat. No. and GTIN table.

Technical Specifications

Specification Product Data
Product Name Locking Head Bone Screw, Self Tapping Ø 2.4 mm
Product Category Trauma – Tibia
Product Type Locking Head Bone Screw
Design Self Tapping
Head Type Locking Head
Nominal Diameter Ø 2.4 mm
Length Range 10–30 mm
Length Increment 2 mm
Available Lengths 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30 mm
Number of Length Options 11
Materials SS316L, Titanium
Potential Basic Configurations Up to 22, subject to catalog confirmation
Bone Thread Geometry Not provided
Thread Pitch Not provided
Core Diameter Not provided
Threaded Length Not provided
Locking Head Thread Geometry Not provided
Head Diameter Not provided
Head Height Not provided
Drive Interface Not provided
Tip Geometry Self-tapping; exact geometry not provided
Compatible Locking Plate Not provided
Compatible Plate Hole Not provided
Compatible Drill Size Not provided
Compatible Tap Not provided
Compatible Screwdriver Not provided
Titanium Grade Not provided
Cat. No. Not provided
GTIN No. Not provided

Technical Overview

Product Name: Locking Head Bone Screw, Self Tapping Ø 2.4 mm

Product Category: Trauma – Tibia

Product Type: Orthopedic Locking Head Bone Screw

Screw Design: Self Tapping

Head Configuration: Locking Head

Nominal Diameter: Ø 2.4 mm

Length Range: 10–30 mm

Length Increment: 2 mm

Length Options: 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, and 30 mm

Number of Length Options: 11

Material Options: SS316L and Titanium

Fixation Concept: Locked plate-and-screw fixation within a compatible orthopedic fixation system

Bone Thread Geometry: Not supplied

Locking Head Geometry: Not supplied

Head / Drive Geometry: Not supplied

Compatible Implant System: Not supplied

Specific Titanium Grade: Not supplied

Compatible Instrumentation: Not supplied

Cat. No.: Not supplied

GTIN No.: Not supplied

Product Features

  • Orthopedic locking fixation screw.
  • Specifically identified as a Locking Head Bone Screw.
  • Specifically identified as Self Tapping.
  • Nominal diameter of Ø 2.4 mm.
  • Available from 10 mm to 30 mm.
  • Uses 2 mm length increments.
  • Available in 10 mm.
  • Available in 12 mm.
  • Available in 14 mm.
  • Available in 16 mm.
  • Available in 18 mm.
  • Available in 20 mm.
  • Available in 22 mm.
  • Available in 24 mm.
  • Available in 26 mm.
  • Available in 28 mm.
  • Available in 30 mm.
  • Provides 11 length configurations.
  • Available in SS316L.
  • Available in Titanium.
  • Features a threaded bone-engaging shaft.
  • Features a manufacturer-defined locking head.
  • Features a self-tapping distal configuration.
  • Includes a proximal insertion interface.
  • Intended for use with a compatible locking plate system.
  • Exact bone-thread pitch should be confirmed from technical drawings.
  • Exact locking-head thread geometry should be confirmed.
  • Exact core diameter should be confirmed.
  • Exact head dimensions should be confirmed.
  • Exact drive interface should be confirmed.
  • Exact drilling and tapping requirements should be confirmed from the surgical technique.
  • Exact compatible locking plate and plate-hole geometry should be confirmed from official system documentation.
  • Exact Titanium alloy should be confirmed.
  • Individual Cat. No. and GTIN No. should be added when the official product matrix is available.
  • Approved indications, contraindications, and insertion technique should be confirmed from the manufacturer’s Instructions for Use (IFU).

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top