Product Explanation
The Locking L-Oblique Distal Radius Plate 2.4/2.7 mm is an orthopedic fixation plate intended to form part of a compatible internal fixation construct in the distal radius region.
A simplified fixation concept can be represented as:
Distal Radius → L-Oblique Locking Plate → Compatible Fixation Screws → Internal Fixation Construct
The plate is selected and positioned according to the anatomical side, fracture configuration, bone anatomy, fixation requirements, surgical plan, approved surgical technique, and Instructions for Use.
According to the supplied product information, the plate is available in:
Left / Right
configurations.
The product incorporates:
3 Head Holes
and is available with:
3 / 4 Shaft Holes
providing alternative shaft configurations within the product family.
Product Components and Design
- L-Oblique Plate Body
The implant consists of an elongated metallic plate with an angled or oblique head-to-shaft relationship.
The product is specifically identified as:
Locking L-Oblique Distal Radius Plate
according to the supplied product image.
The exact angle, anatomical contour, plate curvature, dimensions, and orientation of the L-Oblique geometry are not defined in the supplied image and should be confirmed from the manufacturer’s technical drawings.
- Oblique Head Section
The head section is positioned at an angle relative to the elongated plate shaft.
According to the supplied product data:
Head Holes: 3
These fixation openings form the head section of the plate.
The exact screw type, screw diameter, locking interface, and trajectory associated with each head hole are not specified in the supplied product information.
- Shaft Section
The elongated shaft is available with:
3 Shaft Holes
or
4 Shaft Holes
according to the supplied product data.
These options provide alternative plate configurations for different fixation requirements.
The exact plate lengths corresponding to the 3-hole and 4-hole versions are not provided.
- Multiple Fixation Opening Geometries
The supplied product image visually shows multiple fixation openings distributed through the plate head and shaft.
Circular and elongated openings are visible.
The exact technical function of each opening—such as locking fixation, compression, positioning, or adjustment—is not stated in the supplied image and should be confirmed from the approved surgical technique.
- Left and Right Configurations
The plate is available in:
Left / Right
alignment options.
This supports side-specific implant selection according to the anatomical side being treated.
The exact geometric differences between the Left and Right versions should be confirmed from the manufacturer’s technical drawings.
- Material Options
According to the supplied product information, the plate is available in:
SS316L
and
Titanium
The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the official material specification.
Intended Use
The Locking L-Oblique Distal Radius Plate 2.4/2.7 mm is designed for use as part of a compatible orthopedic fixation system involving the distal radius, according to the approved indications, surgical technique, and Instructions for Use.
Potential applications may involve internal fixation of the distal radius where an L-Oblique plate configuration is included within the approved indications.
The specific fracture classifications, anatomical indications, surgical approach, screw configuration, contraindications, and patient selection criteria should be confirmed from the manufacturer’s official product documentation.
Plate selection may depend on factors including:
- Anatomical side.
- Distal radius anatomy.
- Fracture location and configuration.
- Required fixation construct.
- Plate geometry requirement.
- Required shaft-hole configuration.
- Bone dimensions.
- Bone quality.
- Compatible screw selection.
- Compatible instrumentation.
- Surgical approach.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon according to the approved surgical technique and Instructions for Use.
Key Benefits
L-Oblique Plate Configuration
The product is specifically identified as:
Locking L-Oblique Distal Radius Plate
providing a distinct angled plate geometry within a compatible distal radius fixation system.
The exact biomechanical purpose and approved clinical indications associated with this geometry should be confirmed from the manufacturer’s technical documentation.
Left and Right Anatomical Options
The plate is available in:
Left / Right
configurations, supporting side-specific implant selection.
Three-Hole Head Configuration
According to the supplied product information, the plate incorporates:
3 Head Holes
providing fixation positions within the angled head section.
Multiple Shaft Configurations
The product is available with:
3 Shaft Holes
and
4 Shaft Holes
providing two shaft configuration options.
Two Material Options
According to the supplied product information, the plate is available in:
SS316L
and
Titanium
2.4/2.7 mm Fixation System
The product is identified as:
Locking L-Oblique Distal Radius Plate 2.4/2.7 mm
indicating its association with a compatible 2.4/2.7 mm orthopedic fixation system.
The exact compatible screw diameter and screw type assigned to individual plate openings should be confirmed from the official technical documentation.
Multiple Product Variants
Based on the supplied product information, the family contains variations involving:
- 2 alignment options: Left / Right
- 1 head-hole configuration: 3
- 2 shaft-hole options: 3 / 4
- 2 material options: SS316L / Titanium
This represents up to 8 basic alignment × shaft × material configurations, assuming both shaft-hole options and both materials are available for both Left and Right versions.
The exact number of commercially available configurations should be confirmed from the official Cat. No. table.
Technical Specifications
| Specification | Product Data |
| Product Name | Locking L-Oblique Distal Radius Plate 2.4/2.7 mm |
| Product Category | Trauma – Radius |
| Product Type | Locking Orthopedic Fixation Plate |
| Plate Configuration | L-Oblique |
| Anatomical Region | Distal Radius |
| System Size | 2.4/2.7 mm |
| Alignment | Left, Right |
| Head Holes | 3 |
| Shaft Hole Options | 3, 4 |
| Materials | SS316L, Titanium |
| Potential Basic Configurations | Up to 8, subject to catalog confirmation |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
| Plate Length | Not provided |
| Plate Width | Not provided |
| Plate Thickness | Not provided |
| Oblique Angle | Not provided |
| Compatible Screw Details | Not provided |
| Titanium Grade | Not provided |
| Compatible Instrumentation | Not provided |
Technical Overview
Product Name: Locking L-Oblique Distal Radius Plate 2.4/2.7 mm
Product Category: Trauma – Radius
Product Type: Locking Orthopedic Fixation Plate
Plate Type: L-Oblique
Anatomical Region: Distal Radius
System: 2.4/2.7 mm
Alignment Options: Left and Right
Head Holes: 3
Shaft Hole Options: 3 and 4
Material Options: SS316L and Titanium
Plate Geometry: Elongated plate with an angled / oblique head section
Fixation Concept: Plate-and-screw internal fixation using a compatible orthopedic fixation system
Side-Specific Design: Yes — Left / Right
Cat. No.: Not supplied
GTIN No.: Not supplied
Oblique Angle: Not supplied
Specific Titanium Grade: Not supplied
Plate Dimensions: Not supplied
Specific Screw Compatibility: Not supplied
Product Features
- Locking distal radius plate design.
- Identified as an L-Oblique plate configuration.
- Intended for use within a compatible distal radius fixation system.
- Associated with a 2.4/2.7 mm fixation system according to the product name.
- Available in Left and Right configurations.
- Incorporates 3 head holes.
- Available with 3 shaft holes.
- Available with 4 shaft holes.
- Available in SS316L.
- Available in Titanium.
- Features an elongated plate shaft.
- Features an angled / oblique head-to-shaft geometry.
- Includes multiple fixation openings.
- Includes circular fixation openings visible in the supplied image.
- Includes elongated openings visible in the supplied image.
- Supports side-specific implant selection.
- Supports two shaft-hole configurations.
- Provides multiple possible alignment, shaft, and material variants.
- Exact L-Oblique angle should be confirmed from the technical drawing.
- Exact compatible screw types and diameters should be confirmed from the official technical documentation.
- Exact plate dimensions and thickness should be confirmed from the manufacturer’s technical drawings.
- Individual Cat. No. and GTIN No. should be added when the official catalog table is available.
- Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).


Reviews