Product Explanation
The Locking Proximal Femoral Plate, 5.0 mm is an orthopedic fixation plate intended to form part of a compatible internal fixation construct involving the proximal femur.
A simplified fixation concept can be represented as:
Proximal Femur → Locking Proximal Femoral Plate → Compatible Fixation Screws → Internal Fixation Construct
The plate is selected and positioned according to the anatomical side, proximal femur anatomy, fracture configuration, required fixation construct, plate length, surgical plan, approved surgical technique, and Instructions for Use.
According to the supplied product information, the plate is available in:
Left / Right
configurations.
The shaft is available with:
2 / 4 / 6 / 8 / 10 / 12 / 14 / 16 Shaft Holes
providing a broad range of plate configurations within the same product family.
No numerical Head Holes specification is provided in the supplied table.
Product Components and Design
- Proximal Femoral Plate Body
The implant consists of an elongated metallic fixation plate with a contoured proximal section and a longitudinal shaft.
The product is specifically identified as a:
Proximal Femoral Plate
according to the supplied product designation.
The exact anatomical contour, plate curvature, dimensions, width, thickness, and plate-to-bone relationship should be confirmed from the manufacturer’s technical drawings.
- Proximal Fixation Section
The proximal end of the plate visibly incorporates fixation openings and a contoured geometry.
However, the supplied product data states:
Head Holes: –
Therefore, no official numerical head-hole count is provided.
The exact number, classification, compatible screw type, locking interface, and trajectories of the proximal openings should be confirmed from the manufacturer’s technical documentation rather than inferred solely from the image.
- Shaft Section
According to the supplied product information, the plate is available with:
2 Shaft Holes
4 Shaft Holes
6 Shaft Holes
8 Shaft Holes
10 Shaft Holes
12 Shaft Holes
14 Shaft Holes
16 Shaft Holes
This provides eight listed shaft-hole configurations within the product family.
The exact physical plate length corresponding to each shaft-hole option is not provided.
- Multiple Fixation Opening Geometries
The supplied product image visually shows multiple fixation openings distributed along the plate body.
These include:
- Circular shaft openings.
- Proximal fixation openings.
- Multiple longitudinal fixation positions.
- A contoured proximal region with additional openings.
The exact technical role of each opening—such as locking fixation, conventional fixation, compression, positioning, or another function—is not defined in the supplied image and should be confirmed from the approved surgical technique.
- Contoured Proximal Geometry
The plate visibly incorporates a shaped proximal region rather than maintaining a completely straight profile.
This geometry is consistent with the supplied product designation as a Proximal Femoral Plate.
The exact proximal bend, offset, contour, neck-shaft relationship, and anatomical orientation are not provided in the supplied product data.
- Left and Right Configurations
According to the supplied product information, the plate is available in:
Left / Right
versions.
This supports side-specific implant selection according to the anatomical side being treated.
The exact geometric differences between the Left and Right versions should be confirmed from the manufacturer’s engineering drawings.
- Material Options
According to the supplied product data, the plate is available in:
SS316L
and
Titanium
The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the manufacturer’s official material specification.
Intended Use
The Locking Proximal Femoral Plate, 5.0 mm is designed for use as part of a compatible orthopedic fixation system involving the proximal femur, according to the approved indications, surgical technique, and Instructions for Use.
Potential applications may involve internal fixation of the proximal femur where this plate configuration is included within the manufacturer’s approved indications.
The exact fracture patterns, fracture classifications, anatomical indications, fixation strategy, surgical approach, contraindications, and patient-selection criteria should be confirmed from the official product documentation.
Plate selection may depend on factors including:
- Anatomical side.
- Proximal femur anatomy.
- Fracture location and configuration.
- Required fixation construct.
- Required plate length.
- Required shaft-hole configuration.
- Bone dimensions.
- Bone quality.
- Compatible screw selection.
- Proximal screw trajectory requirements.
- Compatible instrumentation.
- Surgical approach.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Benefits
Proximal Femur-Specific Plate Configuration
The product is specifically identified as a:
Locking Proximal Femoral Plate
providing a dedicated plate configuration within a compatible proximal femur fixation system.
The exact anatomical and biomechanical role of the plate should be confirmed from the manufacturer’s approved documentation.
Left and Right Anatomical Options
The plate is available in:
Left / Right
configurations, supporting side-specific implant selection.
Eight Shaft-Hole Configurations
The product family includes:
2 / 4 / 6 / 8 / 10 / 12 / 14 / 16 Shaft Holes
providing eight plate configurations.
This supports selection among different plate variants according to fixation requirements and surgical planning.
5.0 mm Fixation System
The product is identified as:
Locking Proximal Femoral Plate, 5.0 mm
indicating its association with a compatible 5.0 mm orthopedic fixation system.
The exact compatible screw types and whether all visible openings accept the same screw specification should be confirmed from the manufacturer’s technical documentation.
Two Material Options
According to the supplied product information, the plate is available in:
SS316L
and
Titanium
Broad Plate-Length Range
The available shaft-hole options:
2 → 4 → 6 → 8 → 10 → 12 → 14 → 16
indicate multiple plate variants within the same product family.
The exact physical plate lengths corresponding to these configurations are not supplied and should be confirmed from the manufacturer’s dimensional specifications.
Multiple Product Variants
Based strictly on the supplied product data, the family includes:
- 2 alignment options: Left / Right
- No numerical head-hole configuration specified
- 8 shaft-hole options: 2 / 4 / 6 / 8 / 10 / 12 / 14 / 16
- 2 material options: SS316L / Titanium
If every shaft-hole configuration is available in both alignments and both materials, this could represent up to 32 basic alignment × shaft × material combinations.
However, the supplied image does not provide the complete commercial configuration matrix. The exact number of variants should therefore be confirmed from the official Cat. No. table.
Technical Specifications
| Specification | Product Data |
| Product Name | Locking Proximal Femoral Plate, 5.0 mm |
| Product Category | Trauma – Femur |
| Product Type | Locking Orthopedic Fixation Plate |
| Plate Configuration | Proximal Femoral Plate |
| Anatomical Region | Proximal Femur |
| System Size | 5.0 mm |
| Alignment | Left, Right |
| Head Holes | Not specified |
| Shaft Hole Options | 2, 4, 6, 8, 10, 12, 14, 16 |
| Materials | SS316L, Titanium |
| Potential Basic Configurations | Up to 32, subject to catalog confirmation |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
| Plate Lengths | Not provided |
| Plate Width | Not provided |
| Plate Thickness | Not provided |
| Proximal Contour / Bend | Not provided |
| Compatible Screw Details | Not provided |
| Screw Trajectories | Not provided |
| Titanium Grade | Not provided |
| Compatible Instrumentation | Not provided |
Technical Overview
Product Name: Locking Proximal Femoral Plate, 5.0 mm
Product Category: Trauma – Femur
Product Type: Locking Orthopedic Fixation Plate
Plate Type: Proximal Femoral Plate
Anatomical Region: Proximal Femur
System: 5.0 mm
Alignment Options: Left and Right
Head Holes: Not specified
Shaft Hole Options: 2, 4, 6, 8, 10, 12, 14, and 16
Material Options: SS316L and Titanium
Plate Geometry: Elongated shaft with contoured proximal fixation section
Fixation Concept: Plate-and-screw internal fixation using a compatible orthopedic fixation system
Side-Specific Design: Yes — Left / Right
Cat. No.: Not supplied
GTIN No.: Not supplied
Plate Lengths: Not supplied
Plate Thickness: Not supplied
Specific Titanium Grade: Not supplied
Specific Screw Compatibility: Not supplied
Product Features
- Locking orthopedic fixation plate design.
- Specifically identified as a Proximal Femoral Plate.
- Associated with a 5.0 mm fixation system.
- Available in Left and Right configurations.
- No numerical head-hole count is specified in the supplied product data.
- Available with 2 shaft holes.
- Available with 4 shaft holes.
- Available with 6 shaft holes.
- Available with 8 shaft holes.
- Available with 10 shaft holes.
- Available with 12 shaft holes.
- Available with 14 shaft holes.
- Available with 16 shaft holes.
- Provides eight shaft-hole configurations.
- Available in SS316L.
- Available in Titanium.
- Features an elongated longitudinal shaft.
- Features a contoured proximal fixation section.
- Includes multiple visible fixation openings.
- Includes circular openings along the shaft.
- Supports side-specific implant selection.
- Supports multiple potential plate-length configurations.
- Exact proximal fixation-hole count and classification should be confirmed from official technical documentation.
- Exact compatible screw types and diameters should be confirmed from the manufacturer’s system documentation.
- Exact proximal screw trajectories and locking characteristics should be confirmed from the approved technical drawings.
- Exact plate lengths, proximal contour, width, and thickness should be confirmed from the manufacturer’s dimensional specifications.
- Individual Cat. No. and GTIN No. should be added when the official product table is available.
- Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).


Reviews