Product Explanation
The Locking Proximal Tibial Plate, 3.5 mm is an orthopedic fixation plate intended to form part of a compatible internal fixation construct involving the proximal tibia.
A simplified fixation concept can be represented as:
Proximal Tibia → Locking Proximal Tibial Plate → Compatible Fixation Screws → Internal Fixation Construct
The plate is selected and positioned according to the anatomical side, proximal tibial anatomy, fracture configuration, fixation requirements, required plate length, surgical plan, approved surgical technique, and Instructions for Use.
According to the supplied product information, the plate is available in:
Left / Right
configurations.
The product family includes:
4 / 6 / 8 / 10 / 12 / 14 Shaft Holes
providing multiple plate configurations.
No numerical Head Holes specification is provided in the supplied product data.
Product Components and Design
- Proximal Tibial Plate Body
The implant consists of an elongated metallic fixation plate with a broadened and contoured proximal section connected to a longitudinal shaft.
The product is specifically identified as:
Locking Proximal Tibial Plate
according to the supplied product designation.
The exact anatomical contour, proximal width, plate curvature, dimensions, thickness, and plate-to-bone relationship should be confirmed from the manufacturer’s technical drawings.
- Proximal Fixation Section
The proximal portion of the plate is visibly widened and incorporates multiple fixation openings.
However, the supplied product data states:
Head Holes: –
Therefore, no official numerical head-hole count is specified.
The exact number, classification, compatible screw type, locking interface, screw angle, and trajectory of the proximal openings should be confirmed from the manufacturer’s technical documentation rather than inferred solely from the image.
- Shaft Section
According to the supplied product information, the plate is available with:
4 Shaft Holes
6 Shaft Holes
8 Shaft Holes
10 Shaft Holes
12 Shaft Holes
14 Shaft Holes
This provides six listed shaft-hole configurations within the product family.
The exact physical plate length corresponding to each shaft-hole configuration is not supplied.
- Multiple Fixation Opening Geometries
The supplied product image visually shows several fixation-opening geometries distributed across the proximal region and shaft.
These include:
- Multiple proximal fixation openings.
- Circular shaft openings.
- Elongated / contoured openings.
- Multiple longitudinal fixation positions.
The exact technical function of each opening—such as locking fixation, conventional fixation, compression, positioning, or another role—is not specified in the supplied product information and should be confirmed from the approved surgical technique.
- Contoured Proximal Geometry
The plate features a clearly contoured proximal section rather than a completely straight plate profile.
The exact proximal bend, offset, contour, width, and anatomical orientation are not provided in the supplied image.
These dimensional characteristics should be confirmed from the manufacturer’s engineering drawings.
- Left and Right Configurations
According to the supplied product data, the plate is available in:
Left / Right
versions.
This supports side-specific implant selection.
The exact geometric differences between the Left and Right versions should be confirmed from the manufacturer’s technical drawings.
- Material Options
According to the supplied product information, the plate is available in:
SS316L
and
Titanium
The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the manufacturer’s official material specification.
Intended Use
The Locking Proximal Tibial Plate, 3.5 mm is designed for use as part of a compatible orthopedic fixation system involving the proximal tibia, according to the approved indications, surgical technique, and Instructions for Use.
Potential applications may involve internal fixation of the proximal tibia where this plate configuration is included within the manufacturer’s approved indications.
The exact fracture patterns, fracture classifications, anatomical indications, fixation strategy, surgical approach, contraindications, and patient-selection criteria should be confirmed from the official product documentation.
Plate selection may depend on factors including:
- Anatomical side.
- Proximal tibial anatomy.
- Fracture location and configuration.
- Required proximal fixation pattern.
- Required fixation construct.
- Required shaft-hole configuration.
- Required plate length.
- Bone dimensions.
- Bone quality.
- Compatible screw selection.
- Proximal screw trajectory requirements.
- Compatible instrumentation.
- Surgical approach.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Benefits
Proximal Tibia-Specific Plate Configuration
The product is specifically identified as a:
Locking Proximal Tibial Plate
providing a dedicated plate configuration within a compatible proximal tibia fixation system.
The exact anatomical and biomechanical role of the plate should be confirmed from the manufacturer’s approved documentation.
Left and Right Anatomical Options
The plate is available in:
Left / Right
configurations, supporting side-specific implant selection.
Six Shaft-Hole Configurations
The product family includes:
4 / 6 / 8 / 10 / 12 / 14 Shaft Holes
providing six different plate configurations.
This supports selection among multiple plate variants according to fixation requirements and surgical planning.
3.5 mm Fixation System
The product is identified as:
Locking Proximal Tibial Plate, 3.5 mm
indicating its association with a compatible 3.5 mm orthopedic fixation system.
The exact compatible screw types and whether every visible plate opening accepts a 3.5 mm screw should be confirmed from the manufacturer’s system documentation.
Two Material Options
According to the supplied product data, the plate is available in:
SS316L
and
Titanium
Multiple Plate-Length Configurations
The available shaft-hole options:
4 → 6 → 8 → 10 → 12 → 14
indicate multiple plate variants within the product family.
The corresponding physical plate lengths are not supplied and should be confirmed from the manufacturer’s dimensional specifications.
Multiple Product Variants
Based strictly on the supplied product information, the family includes:
- 2 alignment options: Left / Right
- No numerical head-hole configuration specified
- 6 shaft-hole options: 4 / 6 / 8 / 10 / 12 / 14
- 2 material options: SS316L / Titanium
If every shaft-hole configuration is available in both alignments and both materials, this could represent up to 24 basic alignment × shaft × material combinations.
However, the supplied image does not provide the complete commercial configuration matrix. The exact number of available variants should therefore be confirmed from the official Cat. No. table.
Technical Specifications
| Specification | Product Data |
| Product Name | Locking Proximal Tibial Plate, 3.5 mm |
| Product Category | Trauma – Tibia |
| Product Type | Locking Orthopedic Fixation Plate |
| Plate Configuration | Proximal Tibial Plate |
| Anatomical Region | Proximal Tibia |
| System Size | 3.5 mm |
| Alignment | Left, Right |
| Head Holes | Not specified |
| Shaft Hole Options | 4, 6, 8, 10, 12, 14 |
| Number of Shaft-Hole Options | 6 |
| Materials | SS316L, Titanium |
| Potential Basic Configurations | Up to 24, subject to catalog confirmation |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
| Plate Lengths | Not provided |
| Proximal Plate Width | Not provided |
| Plate Thickness | Not provided |
| Proximal Contour / Bend Geometry | Not provided |
| Compatible Screw Details | Not provided |
| Screw Trajectories | Not provided |
| Titanium Grade | Not provided |
| Compatible Instrumentation | Not provided |
Technical Overview
Product Name: Locking Proximal Tibial Plate, 3.5 mm
Product Category: Trauma – Tibia
Product Type: Locking Orthopedic Fixation Plate
Plate Type: Proximal Tibial Plate
Anatomical Region: Proximal Tibia
System: 3.5 mm
Alignment Options: Left and Right
Head Holes: Not specified
Shaft Hole Options: 4, 6, 8, 10, 12, and 14
Material Options: SS316L and Titanium
Plate Geometry: Contoured proximal fixation region with elongated shaft
Fixation Concept: Plate-and-screw internal fixation using a compatible orthopedic fixation system
Side-Specific Design: Yes — Left / Right
Cat. No.: Not supplied
GTIN No.: Not supplied
Plate Lengths: Not supplied
Plate Thickness: Not supplied
Specific Titanium Grade: Not supplied
Specific Screw Compatibility: Not supplied
Product Features
- Locking orthopedic fixation plate design.
- Specifically identified as a Proximal Tibial Plate.
- Included within the Trauma – Tibia product category.
- Associated with a 3.5 mm fixation system.
- Available in Left and Right configurations.
- No numerical head-hole count is specified in the supplied product data.
- Available with 4 shaft holes.
- Available with 6 shaft holes.
- Available with 8 shaft holes.
- Available with 10 shaft holes.
- Available with 12 shaft holes.
- Available with 14 shaft holes.
- Provides six shaft-hole configurations.
- Available in SS316L.
- Available in Titanium.
- Features a broadened contoured proximal fixation section.
- Features an elongated longitudinal shaft.
- Includes multiple visible proximal fixation openings.
- Includes circular and elongated / contoured openings.
- Supports side-specific implant selection.
- Supports multiple potential plate-length configurations.
- Exact proximal head-hole count and classification should be confirmed from official technical documentation.
- Exact compatible screw types and diameters should be confirmed from the manufacturer’s system documentation.
- Exact proximal screw trajectories and locking characteristics should be confirmed from the approved technical drawings.
- Exact plate lengths, proximal contour, proximal width, and thickness should be confirmed from the manufacturer’s dimensional specifications.
- Individual Cat. No. and GTIN No. should be added when the official product table is available.
- Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).


Reviews