Product Explanation
The Locking T Distal Radius Plate 2.4/2.7 mm is an orthopedic plate intended to form part of a compatible internal fixation construct in the distal radius region.
A simplified fixation concept can be represented as:
Distal Radius → T-Shaped Locking Plate → Compatible Fixation Screws → Internal Fixation Construct
The plate is selected and positioned according to the applicable anatomy, fracture configuration, fixation requirements, surgical plan, approved surgical technique, and Instructions for Use.
According to the supplied product data, the plate has a:
T-Straight
alignment and incorporates:
3 Head Holes
with two available shaft configurations:
3 Shaft Holes / 4 Shaft Holes
Product Components and Design
- T-Shaped Plate Body
The implant consists of an elongated metallic shaft with a widened transverse head section, creating a characteristic T-shaped configuration.
The product is specifically identified as:
Locking T Distal Radius Plate
according to the supplied product image.
The exact anatomical contour, transverse head width, shaft length, plate curvature, and plate-to-bone relationship should be confirmed from the manufacturer’s technical drawings.
- Transverse Head Section
The widened head section forms the upper portion of the T-shaped plate.
According to the supplied product information:
Head Holes: 3
These openings provide fixation positions within the plate head.
The exact screw diameter, screw type, locking interface, and screw trajectory associated with each opening are not specified in the supplied image.
- Shaft Section
The elongated shaft is available with:
3 Shaft Holes
or
4 Shaft Holes
according to the supplied product data.
These two options provide alternative plate configurations within the product family.
The exact plate length corresponding to each shaft-hole configuration is not provided.
- Multiple Fixation Openings
The supplied product image visually shows multiple openings distributed throughout the plate head and shaft.
Circular and elongated openings are visible.
The specific function of each opening—such as locking fixation, conventional fixation, compression, positioning, or adjustment—is not defined in the supplied product information and should be confirmed from the approved surgical technique.
- T-Straight Alignment
According to the supplied product data:
Alignment: T-Straight
No separate Left or Right alignment is listed for this product.
The exact anatomical orientation and permitted positioning of the T-Straight configuration should be confirmed from the official product documentation.
- Material Options
According to the supplied product image, the plate is available in:
SS316L
and
Titanium
The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the official material specification.
Intended Use
The Locking T Distal Radius Plate 2.4/2.7 mm is designed for use as part of a compatible orthopedic fixation system involving the distal radius, according to the approved indications, surgical technique, and Instructions for Use.
Potential applications may involve internal fixation in the distal radius region where a T-shaped plate configuration is included within the manufacturer’s approved indications.
The exact fracture classifications, anatomical indications, surgical approach, screw configuration, contraindications, and patient selection criteria should be confirmed from the official product documentation.
Plate selection may depend on factors including:
- Distal radius anatomy.
- Fracture location and configuration.
- Required fixation construct.
- Required shaft-hole configuration.
- Bone dimensions.
- Bone quality.
- Plate geometry requirement.
- Compatible screw selection.
- Compatible instrumentation.
- Surgical approach.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Benefits
T-Shaped Plate Configuration
The product is specifically identified as:
Locking T Distal Radius Plate
providing a T-shaped fixation plate configuration within a compatible distal radius system.
The exact biomechanical role and approved indications of this geometry should be confirmed from the official technical documentation.
Three-Hole Head Configuration
The product incorporates:
3 Head Holes
according to the supplied product data.
These provide multiple fixation positions across the transverse head section.
Two Shaft Configurations
The plate is available with:
3 Shaft Holes
and
4 Shaft Holes
providing alternative shaft configurations.
Two Material Options
According to the supplied product data, the plate is available in:
SS316L
and
Titanium
2.4/2.7 mm Fixation System
The product is identified as:
Locking T Distal Radius Plate 2.4/2.7 mm
indicating its association with a compatible 2.4/2.7 mm orthopedic fixation system.
The exact compatible screw size assigned to each plate opening should be confirmed from the official technical documentation.
Straight T-Configuration
The product is identified as:
T-Straight
rather than Left or Right.
This provides a distinct configuration within the distal radius plate family.
Multiple Basic Product Configurations
Based strictly on the supplied data, the product family includes:
- 1 alignment: T-Straight
- 1 head-hole configuration: 3
- 2 shaft-hole options: 3 / 4
- 2 material options: SS316L / Titanium
This represents up to 4 basic shaft × material configurations, assuming both materials are available in both shaft-hole versions.
The exact number of commercially available configurations should be confirmed from the official Cat. No. table.
Technical Specifications
| Specification | Product Data |
| Product Name | Locking T Distal Radius Plate 2.4/2.7 mm |
| Product Category | Trauma – Radius |
| Product Type | Locking Orthopedic Fixation Plate |
| Plate Configuration | T-shaped |
| Anatomical Region | Distal Radius |
| System Size | 2.4/2.7 mm |
| Alignment | T-Straight |
| Head Holes | 3 |
| Shaft Hole Options | 3, 4 |
| Materials | SS316L, Titanium |
| Potential Basic Configurations | Up to 4, subject to catalog confirmation |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
| Plate Length | Not provided |
| Plate Width | Not provided |
| Plate Thickness | Not provided |
| Compatible Screw Details | Not provided |
| Titanium Grade | Not provided |
| Compatible Instrumentation | Not provided |
Technical Overview
Product Name: Locking T Distal Radius Plate 2.4/2.7 mm
Product Category: Trauma – Radius
Product Type: Locking Orthopedic Fixation Plate
Plate Type: T-shaped
Anatomical Region: Distal Radius
System: 2.4/2.7 mm
Alignment: T-Straight
Head Holes: 3
Shaft Hole Options: 3 and 4
Material Options: SS316L and Titanium
Plate Geometry: Transverse T-shaped head with elongated shaft
Fixation Concept: Plate-and-screw internal fixation using a compatible orthopedic fixation system
Side-Specific Design: Not specified
Cat. No.: Not supplied
GTIN No.: Not supplied
Specific Titanium Grade: Not supplied
Plate Dimensions: Not supplied
Specific Screw Compatibility: Not supplied
Product Features
- Locking distal radius plate design.
- Identified as a T-shaped plate configuration.
- T-Straight alignment.
- Intended for use within a compatible distal radius fixation system.
- Associated with a 2.4/2.7 mm fixation system according to the product name.
- Incorporates 3 head holes.
- Available with 3 shaft holes.
- Available with 4 shaft holes.
- Available in SS316L.
- Available in Titanium.
- Features a widened transverse head section.
- Features an elongated shaft section.
- Includes multiple fixation openings.
- Includes circular fixation openings visible in the supplied image.
- Includes elongated openings visible in the supplied image.
- Supports two shaft-hole configurations.
- Provides multiple possible shaft and material variants.
- Exact screw compatibility should be confirmed from official technical documentation.
- Exact plate length, width, and thickness should be confirmed from the manufacturer’s technical drawings.
- Individual Cat. No. and GTIN No. should be added when the official catalog table is available.
Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).


Reviews