Locking T Small Plate, 3.5 mm

Locking T Small Plate | 3.5 mm | Simple Configuration | 3–8 Shaft Holes | SS316L / Titanium

The Locking T Small Plate, 3.5 mm is an orthopedic fixation plate designed for use within a compatible 3.5 mm fixation system.

According to the supplied product image, the plate is identified with a Simple alignment/configuration, has no separately specified head-hole count, and is available with 3, 4, 5, 6, or 8 shaft holes. The plate is manufactured from either SS316L or Titanium.

The supplied product information identifies:

  • Product Name: Locking T Small Plate, 3.5 mm
  • Product Configuration: T-shaped Small Plate
  • Alignment: Simple
  • Head Holes: Not specified
  • Shaft Holes: 3, 4, 5, 6, 8
  • Material Options: SS316L, Titanium
  • System Size: 3.5 mm
  • Anatomical Region: Not specified in the supplied image

The exact plate dimensions, anatomical indication, plate thickness, locking mechanism, screw trajectories, compatible screw types, Cat. No., GTIN No., and compatible instrumentation are not provided in the supplied image and should be confirmed from the official technical documentation and Instructions for Use.

Product Explanation

The Locking T Small Plate, 3.5 mm is an orthopedic fixation plate intended to form part of a compatible internal fixation construct.

A simplified fixation concept can be represented as:

Prepared Bone → T-Shaped Locking Plate → Compatible Fixation Screws → Internal Fixation Construct

The plate features a characteristic T-shaped geometry, consisting of a widened transverse head section connected to an elongated shaft.

According to the supplied product information, the plate is identified as:

Simple

and is available with:

3 / 4 / 5 / 6 / 8 Shaft Holes

providing multiple plate configurations within the product family.

The specific anatomical region and approved clinical indications are not stated in the supplied image and should therefore be confirmed from the manufacturer’s official documentation.

Product Components and Design

  1. T-Shaped Plate Body

The implant consists of a metallic fixation plate with a broadened transverse section at one end and an elongated longitudinal shaft.

This creates the characteristic:

T-shaped plate geometry

shown in the supplied product image.

The exact plate contour, transverse-head width, shaft length, plate thickness, and anatomical relationship are not provided in the supplied data.

  1. Transverse Head Section

The upper portion of the plate forms a widened T-shaped head and visibly incorporates several fixation openings.

However, the supplied product table states:

Head Holes: –

Therefore, no official numerical head-hole count is provided.

The exact number, classification, locking characteristics, compatible screw type, and trajectory of the visible head openings should be confirmed from the manufacturer’s technical documentation rather than inferred solely from the image.

  1. Shaft Section

According to the supplied product data, the plate is available with:

3 Shaft Holes

4 Shaft Holes

5 Shaft Holes

6 Shaft Holes

8 Shaft Holes

This provides five different shaft configurations within the same product family.

The exact physical plate length corresponding to each shaft-hole option is not provided.

  1. Multiple Fixation Opening Geometries

The supplied image visually shows different fixation opening geometries distributed across the plate.

These include:

  • Circular openings within the T-shaped head.
  • Circular shaft openings.
  • Elongated / contoured openings within the shaft.
  • Additional fixation openings along the longitudinal plate body.

The exact technical function of each opening—such as locking fixation, conventional fixation, compression, positioning, or adjustment—is not specified in the supplied product information and should be confirmed from the approved surgical technique.

  1. Simple Configuration

According to the supplied product data:

Alignment: Simple

This designation is reproduced exactly from the supplied image.

The image does not define what the manufacturer means technically by Simple, nor does it specify Left, Right, Straight, or side-specific versions.

Therefore, the exact meaning of this configuration should be confirmed from the manufacturer’s catalog.

  1. Material Options

According to the supplied product information, the plate is available in:

SS316L

and

Titanium

The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the manufacturer’s material specification.

Intended Use

The Locking T Small Plate, 3.5 mm is designed for use as part of a compatible orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.

The supplied image does not specify the exact anatomical region or approved clinical application.

Potential use should therefore be described only in general terms as orthopedic plate fixation within procedures for which this implant has been approved by the manufacturer.

The exact anatomical indication, fracture type, surgical approach, fixation strategy, contraindications, and patient-selection criteria should be confirmed from the official product documentation.

Plate selection may depend on factors including:

  • Anatomical location.
  • Bone dimensions.
  • Fracture location and configuration.
  • Required fixation construct.
  • Required plate geometry.
  • Required shaft-hole configuration.
  • Required plate length.
  • Bone quality.
  • Compatible screw selection.
  • Compatible instrumentation.
  • Surgical approach.
  • Preoperative planning.
  • Intraoperative assessment.

The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.

Key Benefits

T-Shaped Plate Configuration

The product is specifically identified as a:

Locking T Small Plate

providing a distinct T-shaped geometry within a compatible orthopedic fixation system.

The exact anatomical purpose of the T-shaped configuration should be confirmed from the manufacturer’s documentation.

Compact Small Plate Design

The product designation includes:

Small Plate

indicating a compact plate configuration within the product family.

The exact physical dimensions defining the Small version are not supplied and should be confirmed from the technical drawings.

Five Shaft-Hole Options

The plate is available with:

3 / 4 / 5 / 6 / 8 Shaft Holes

providing five shaft configurations.

This supports selection among different plate variants according to the required fixation construct.

3.5 mm Fixation System

The product is identified as:

Locking T Small Plate, 3.5 mm

indicating its association with a compatible 3.5 mm orthopedic fixation system.

The exact compatible screw type, locking screw specification, and hole-specific screw assignment should be confirmed from the manufacturer’s official technical documentation.

Two Material Options

According to the supplied product information, the plate is available in:

SS316L

and

Titanium

Multiple Plate Configurations

Based strictly on the supplied product information, the family includes:

  • 1 listed alignment/configuration: Simple
  • No numerical head-hole configuration specified
  • 5 shaft-hole options: 3 / 4 / 5 / 6 / 8
  • 2 material options: SS316L / Titanium

If each shaft-hole configuration is available in both materials, this could represent up to 10 basic shaft × material combinations.

The exact commercial configuration matrix should be confirmed from the official Cat. No. table.

Technical Specifications

Specification Product Data
Product Name Locking T Small Plate, 3.5 mm
Product Category Orthopedic Fixation Plate
Product Type Locking T-Shaped Plate
Plate Configuration T Small Plate
Anatomical Region Not specified
System Size 3.5 mm
Alignment / Configuration Simple
Head Holes Not specified
Shaft Hole Options 3, 4, 5, 6, 8
Materials SS316L, Titanium
Potential Basic Configurations Up to 10, subject to catalog confirmation
Cat. No. Not provided
GTIN No. Not provided
Plate Lengths Not provided
Head Width Not provided
Plate Width Not provided
Plate Thickness Not provided
Compatible Screw Details Not provided
Screw Trajectories Not provided
Titanium Grade Not provided
Compatible Instrumentation Not provided

Technical Overview

Product Name: Locking T Small Plate, 3.5 mm

Product Category: Orthopedic Fixation

Product Type: Locking Orthopedic Fixation Plate

Plate Type: T Small Plate

System: 3.5 mm

Anatomical Region: Not specified

Alignment / Configuration: Simple

Head Holes: Not specified

Shaft Hole Options: 3, 4, 5, 6, and 8

Material Options: SS316L and Titanium

Plate Geometry: T-shaped transverse head with elongated shaft

Fixation Concept: Plate-and-screw internal fixation using a compatible orthopedic fixation system

Side-Specific Design: Not specified

Cat. No.: Not supplied

GTIN No.: Not supplied

Plate Lengths: Not supplied

Plate Thickness: Not supplied

Specific Titanium Grade: Not supplied

Specific Screw Compatibility: Not supplied

Product Features

  • Locking orthopedic fixation plate design.
  • Specifically identified as a T Small Plate.
  • Features a T-shaped plate geometry.
  • Associated with a 3.5 mm fixation system.
  • Alignment / configuration identified as Simple.
  • No numerical head-hole count is specified in the supplied product data.
  • Available with 3 shaft holes.
  • Available with 4 shaft holes.
  • Available with 5 shaft holes.
  • Available with 6 shaft holes.
  • Available with 8 shaft holes.
  • Available in SS316L.
  • Available in Titanium.
  • Features a widened transverse head section.
  • Features an elongated shaft.
  • Includes multiple visible fixation openings.
  • Includes circular openings visible in the supplied product image.
  • Includes elongated / contoured shaft openings visible in the supplied image.
  • Supports five shaft-hole configurations.
  • Supports multiple potential plate-length variants.
  • Exact anatomical indication should be confirmed from official documentation.
  • Exact meaning of “Simple” alignment should be confirmed from the manufacturer’s catalog.
  • Exact head-hole count and classification should be confirmed from technical documentation.
  • Exact compatible screw types and diameters should be confirmed from the manufacturer’s system documentation.
  • Exact screw trajectories and locking characteristics should be confirmed from the approved technical drawings.
  • Exact plate lengths, head width, plate width, and thickness should be confirmed from the manufacturer’s dimensional specifications.
  • Individual Cat. No. and GTIN No. should be added when the official product table is available.
  • Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top