Locking Wrist Fusion Plate, 2.4 mm

Locking Wrist Fusion Plate, 2.4 mm | Straight / Short Bend / Standard Bend | SS316L / Titanium

The Locking Wrist Fusion Plate, 2.4 mm is an orthopedic fixation plate designed for use within a compatible wrist fusion fixation system.

According to the supplied product image, the plate is available in three alignment or profile configurations:

Straight / Short Bend / Standard Bend

and is manufactured from either:

SS316L / Titanium

The supplied product information identifies:

  • Product Name: Locking Wrist Fusion Plate, 2.4 mm
  • Anatomical Region: Wrist
  • Plate Configuration: Wrist Fusion Plate
  • Alignment Options: Straight, Short Bend, Standard Bend
  • Head Holes: Not specified
  • Shaft Holes: Listed in the supplied image as 112, 118, 118
  • Material Options: SS316L, Titanium
  • System Size: 2.4 mm

The exact plate dimensions, hole count, screw compatibility, locking mechanism, fusion-specific positioning, Cat. No., GTIN No., and compatible instrumentation are not fully defined in the supplied image and should be confirmed from the official technical documentation and Instructions for Use.

Product Explanation

The Locking Wrist Fusion Plate, 2.4 mm is an orthopedic fixation plate intended to form part of a compatible fixation construct involving the wrist.

Based on the supplied product designation, the plate belongs to a:

Wrist Fusion Fixation System

A simplified fixation concept can be represented as:

Prepared Wrist Anatomy → Wrist Fusion Plate → Compatible Fixation Screws → Stabilized Fusion Construct

The plate is selected and positioned according to the applicable anatomy, required plate profile, fixation requirements, bone dimensions, surgical plan, approved surgical technique, and Instructions for Use.

According to the supplied product information, three plate profiles are available:

Straight

Short Bend

Standard Bend

These different geometries provide alternative plate profiles within the same product family.

Product Components and Design

  1. Wrist Fusion Plate Body

The implant consists of an elongated metallic fixation plate designed as part of a compatible wrist fusion system.

The supplied image visually shows several elongated plate configurations with different longitudinal profiles.

The exact plate contour, curvature, dimensions, anatomical contact surfaces, and fusion-specific geometry should be confirmed from the manufacturer’s technical drawings.

  1. Straight Configuration

One version is identified as:

Straight

This configuration has a comparatively straight longitudinal plate profile.

The exact length, curvature, anatomical positioning, and intended application of the Straight version are not specified in the supplied image.

  1. Short Bend Configuration

A second version is identified as:

Short Bend

This indicates a plate configuration incorporating a bend within its longitudinal geometry.

The exact bend angle, bend location, plate length, and anatomical relationship should be confirmed from the official technical drawings.

  1. Standard Bend Configuration

A third version is identified as:

Standard Bend

This provides another contoured plate geometry within the product family.

The exact distinction between Short Bend and Standard Bend, including dimensional and angular differences, is not provided in the supplied image and should not be assumed.

  1. Multiple Fixation Openings

The supplied product image visually shows numerous fixation openings distributed along the length of the plates.

Different opening geometries appear to be incorporated into the plate design.

The exact number, classification, and function of these openings—such as locking fixation, conventional fixation, compression, positioning, or another function—are not defined by the supplied table and should be confirmed from the approved surgical technique.

  1. Head-Hole Configuration

According to the supplied product data:

Head Holes: –

Therefore, no separate numerical head-hole configuration is specified.

This should not be interpreted as meaning that the plate contains no fixation openings in a particular region; it simply means the supplied catalog table does not define a separate head-hole count.

  1. Material Options

According to the supplied product image, the plate is available in:

SS316L

and

Titanium

The specific Titanium alloy or grade is not stated in the supplied image and should be confirmed from the official material specification.

Intended Use

The Locking Wrist Fusion Plate, 2.4 mm is designed for use as part of a compatible orthopedic fixation system involving the wrist, according to the approved indications, surgical technique, and Instructions for Use.

Based on the product designation, the plate is associated with wrist fusion procedures.

Potential use may involve stabilization of a wrist fusion construct where this implant is included within the manufacturer’s approved indications.

The exact fusion procedure, anatomical levels involved, surgical approach, fixation pattern, contraindications, and patient-selection criteria must be confirmed from the official product documentation.

Plate selection may depend on factors including:

  • Wrist anatomy.
  • Required fusion construct.
  • Required plate profile.
  • Straight versus bent configuration.
  • Bone dimensions.
  • Bone quality.
  • Fixation requirements.
  • Compatible screw selection.
  • Compatible instrumentation.
  • Surgical approach.
  • Preoperative planning.
  • Intraoperative assessment.

The implant should be selected and implanted by a qualified orthopedic surgeon according to the approved surgical technique and Instructions for Use.

Key Benefits

Three Plate Profile Options

The product family includes:

Straight

Short Bend

Standard Bend

providing three alternative plate profiles for implant selection.

Dedicated Wrist Fusion Configuration

The product is specifically identified as a:

Locking Wrist Fusion Plate

providing a dedicated plate family within a compatible wrist fixation system.

The exact approved fusion applications should be verified from the manufacturer’s IFU.

2.4 mm Fixation System

The product is identified as:

Locking Wrist Fusion Plate, 2.4 mm

indicating its association with a compatible 2.4 mm orthopedic fixation system.

The exact screw size, type, and hole-specific compatibility should be confirmed from the official technical documentation.

Two Material Options

According to the supplied product information, the plate is available in:

SS316L

and

Titanium

Multiple Geometric Configurations

The product family provides different longitudinal geometries rather than a single plate profile.

This allows selection between:

  • Straight geometry.
  • Short Bend geometry.
  • Standard Bend geometry.

The exact dimensional differences between these configurations should be confirmed from the manufacturer’s product drawings.

Technical Specifications

Specification Product Data
Product Name Locking Wrist Fusion Plate, 2.4 mm
Product Category Trauma / Wrist Fixation
Product Type Locking Orthopedic Fixation Plate
Plate Configuration Wrist Fusion Plate
Anatomical Region Wrist
System Size 2.4 mm
Alignment / Profile Options Straight, Short Bend, Standard Bend
Head Holes Not specified
“Shaft Holes” as listed in image 112, 118, 118
Materials SS316L, Titanium
Cat. No. Not provided
GTIN No. Not provided
Plate Length Not clearly provided
Plate Width Not provided
Plate Thickness Not provided
Bend Angles Not provided
Compatible Screw Details Not provided
Titanium Grade Not provided
Compatible Instrumentation Not provided

Technical Overview

Product Name: Locking Wrist Fusion Plate, 2.4 mm

Product Category: Trauma / Wrist Fixation

Product Type: Locking Orthopedic Fixation Plate

Plate Type: Wrist Fusion Plate

Anatomical Region: Wrist

System: 2.4 mm

Alignment / Profile Options: Straight, Short Bend, Standard Bend

Head Holes: Not specified

Shaft Holes: Supplied table states 112, 118, 118 — requires verification

Material Options: SS316L and Titanium

Plate Geometry: Elongated fixation plate available in straight and bent profiles

Fixation Concept: Plate-and-screw fixation within a compatible wrist fusion construct

Side-Specific Design: Not specified

Cat. No.: Not supplied

GTIN No.: Not supplied

Specific Titanium Grade: Not supplied

Plate Dimensions: Not confirmed

Specific Screw Compatibility: Not supplied

Product Features

  • Locking wrist fixation plate design.
  • Specifically identified as a Wrist Fusion Plate.
  • Associated with a 2.4 mm fixation system according to the supplied product name.
  • Available in Straight configuration.
  • Available in Short Bend configuration.
  • Available in Standard Bend configuration.
  • Available in SS316L.
  • Available in Titanium.
  • Features an elongated fixation plate geometry.
  • Includes multiple visible fixation openings.
  • Available with different longitudinal plate profiles.
  • No separate numerical head-hole configuration is supplied.
  • Side-specific Left / Right versions are not specified.
  • Exact bend angles are not supplied.
  • Exact compatible screw types and diameters should be confirmed from official technical documentation.
  • Exact plate dimensions and profile differences should be confirmed from the manufacturer’s technical drawings.
  • Individual Cat. No. and GTIN No. should be added when the official product table is available.
  • Approved indications, contraindications, fusion technique, and instrumentation should be confirmed from the manufacturer’s Instructions for Use (IFU).

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top