Pointed Trocar Wires

Orthopedic Trocar-Tip Fixation Wires | Ø1.5 / Ø1.8 / Ø2.0 MM | Lengths 300 & 400 MM | Cat. No. AMS 602.150

Pointed Trocar Wires are Orthopedic Fixation Wires designed with a pointed Trocar Tip to facilitate guidance and entry into bone during compatible orthopedic fixation applications. They are available in diameters of 1.5, 1.8, and 2.0 mm and lengths of 300 and 400 mm, providing multiple configuration options according to surgical requirements.

  • Trocar Point Tip Design provides pointed tip geometry intended for interaction with bone according to the approved Surgical Technique.
  • Available in three diameters: Ø1.5, Ø1.8, and Ø2.0 mm.
  • Each diameter is available in 300 mm and 400 mm lengths, providing a total of 6 Configurations.
  • A Dedicated Cat. No. is assigned to each Diameter / Length combination to facilitate Product Identification, Surgical Set Preparation, and Inventory Management.

Pointed Trocar Wires are Orthopedic Fixation Wires designed for use in orthopedic procedures requiring a thin, straight wire with a pointed Trocar Tip to support guidance and advancement into bone according to the applicable surgical technique and fixation system.

The product features a Straight Wire Shaft with a Pointed Distal Tip, providing geometry suitable for compatible Orthopedic Fixation, Pinning, or auxiliary fixation applications, according to the indications specified by the manufacturer.

According to the provided data, the range is available in three diameters: 1.5 mm, 1.8 mm, and 2.0 mm. Each diameter is available in two lengths: 300 mm and 400 mm, resulting in a total of 6 Product Configurations.

This variation in Wire Diameter and Wire Length allows the surgical team to select the appropriate configuration according to Bone Anatomy, Fixation Site, Required Trajectory, Working Length, and the requirements of the surgical procedure.

The product family is listed under the general reference:

Cat. No.: AMS 602.150

An individual Cat. No. is assigned to each diameter and length combination, supporting Product Identification, Surgical Set Preparation, Procurement, Inventory Management, and Stock Control.

What Are Pointed Trocar Wires?

A Pointed Trocar Wire is a straight metallic surgical wire featuring a pointed Trocar-Type Point, designed for orthopedic surgical applications requiring insertion of a wire into or through bone structures according to the appropriate surgical technique.

Depending on the fixation system and approved indications, this category of wires may be used in applications such as:

  • Orthopedic Pinning
  • Temporary Bone Fixation
  • Fragment Positioning
  • Guidance during selected Bone Fixation procedures
  • Use as part of a compatible Fixation Construct

More specialized clinical indications should not be stated unless specifically defined in the product IFU.

Product Components and Design

  1. Trocar Point

The pointed end of the wire featuring Trocar Point Geometry.

This design supports guidance of the wire during insertion according to the fixation trajectory determined by the surgeon.

  1. Wire Shaft

The straight longitudinal body of the wire, defined by parameters including:

  • Wire Diameter
  • Working Length
  • External Instrument Interface
  1. Proximal End

The proximal section of the wire used for handling with the compatible insertion or Driving Instrument.

The specific insertion instrument or Chuck Interface is not identified in the provided table.

  1. Diameter-Specific Configuration

The product range is available in three diameters:

Ø1.5 mm – Ø1.8 mm – Ø2.0 mm

providing multiple Wire Diameter options.

  1. Length-Specific Configuration

Each diameter is available in two lengths:

300 mm – 400 mm

allowing selection of an appropriate Working Length according to the surgical procedure.

Product Use

Pointed Trocar Wires are used in Orthopedic Fixation applications requiring a pointed wire for interaction with bone structures.

General applications, subject to the applicable IFU and compatible fixation system, may include:

  • Temporary Bone Fixation
  • Orthopedic Pinning
  • Bone Fragment Stabilization
  • Alignment and Positioning Assistance
  • Guidance during selected Internal or External Fixation procedures
  • Temporary fixation during preparation of the Final Fixation Construct

Selection of the appropriate Diameter and Length depends on factors including:

  • Bone Anatomy
  • Bone Dimensions
  • Fixation Site
  • Required Wire Trajectory
  • Required Penetration / Working Length
  • Surgical Approach
  • Intraoperative Assessment

The product should be selected and used by a Qualified Orthopedic Surgeon in accordance with the applicable Surgical Technique and IFU.

Key Benefits

Trocar Point Geometry

The pointed Trocar Point design provides Tip Geometry intended to support guidance and advancement into bone structures according to the applicable surgical technique.

Multiple Diameter Options

The range is available in:

1.5 / 1.8 / 2.0 mm

providing multiple options during Wire Selection.

Two Length Options

Each diameter is available in:

300 / 400 mm

providing more than one Working Length within the product range.

Six Product Configurations

The range provides:

3 Diameters × 2 Lengths = 6 Configurations

Surgical Selection Flexibility

The combination of different diameters and lengths allows selection of an appropriate Wire Configuration according to the procedure and bone anatomy.

Clear Product Coding

An individual Cat. No. for each configuration supports:

  • Product Identification
  • Surgical Set Preparation
  • Procurement
  • Inventory Management
  • Stock Control

Technical Specifications

Diameter Length Cat. No.
Ø1.5 mm 300 mm AMS 602.150.300
Ø1.5 mm 400 mm AMS 602.150.400
Ø1.8 mm 300 mm AMS 602.180.300
Ø1.8 mm 400 mm AMS 602.180.400
Ø2.0 mm 300 mm AMS 602.120.300
Ø2.0 mm 400 mm AMS 602.120.400

Technical Overview

Product Name: Pointed Trocar Wires

Product Type: Orthopedic Trocar-Tip Wire

Product Category: Orthopedic Fixation Wire

Tip Design: Pointed Trocar

General Cat. No.: AMS 602.150

Available Diameters: Ø1.5 / Ø1.8 / Ø2.0 mm

Diameter Range: 1.5–2.0 mm

Available Lengths: 300 / 400 mm

Configurations per Diameter: 2

Total Configurations: 6

Primary Function: Orthopedic Fixation / Pinning according to system indications

Identification: Individual Cat. No. for each Diameter / Length combination

Product Features

  • Pointed Trocar Tip Design.
  • Designed for compatible Orthopedic Fixation applications.
  • Straight Wire Geometry.
  • Available in three different Wire Diameters.
  • Diameter range from Ø1.5 to Ø2.0 mm.
  • Two available lengths: 300 and 400 mm.
  • Total of 6 Configurations.
  • Provides multiple options during Wire Selection.
  • Supports selection of an appropriate Working Length according to the surgical procedure.
  • Suitable for Temporary Fixation / Pinning when included within the approved indications.
  • Can be used with compatible Orthopedic Fixation systems and instruments.
  • Individual Cat. No. for each Diameter / Length combination.
  • Facilitates Product Identification and Surgical Set Preparation.
  • Supports Procurement, Inventory Management, and Stock Control.