Locking Distal Radius Plate 2.4/2.7 mm

Locking Distal Radius Plate 2.4/2.7 mm | Left & Right | SS316L / Titanium

The Locking Distal Radius Plate 2.4/2.7 mm is an orthopedic fixation plate designed for use within compatible distal radius fixation systems.

According to the supplied product image, the plate is available in Left and Right alignment options, with 3-hole and 5-hole shaft configurations, and is manufactured from either SS316L or Titanium.

The supplied image identifies the following product data:

  • Product Name: Locking Distal Radius Plate 2.4/2.7 mm
  • Anatomical Category: Radius
  • Alignment: Left, Right
  • Head Holes: 2, according to the supplied product data
  • Shaft Holes: 3, 5
  • Material Options: SS316L, Titanium
  • System Size: 2.4/2.7 mm

The specific screw compatibility, locking mechanism, plate dimensions, thickness, Cat. No., GTIN No., and instrumentation are not defined in the supplied image and should be confirmed from the official technical documentation and Instructions for Use.

Product Explanation

The Locking Distal Radius Plate 2.4/2.7 mm is an orthopedic plate intended to form part of a compatible internal fixation construct for the distal radius.

A simplified fixation concept can be represented as:

Distal Radius → Locking Plate → Compatible Fixation Screws → Internal Fixation Construct

The plate is positioned according to the applicable anatomy, fracture configuration, surgical plan, and approved surgical technique.

According to the supplied image, the plate is available in both:

Left / Right

orientations to support side-specific anatomical selection.

Different shaft-hole configurations are also available:

3 Holes / 5 Holes

allowing selection according to the required plate configuration and surgical plan.

Product Components and Design

  1. Anatomically Shaped Plate Body

The implant consists of a metallic plate body with a widened distal section and an elongated shaft.

The geometry shown in the supplied image appears designed to follow the general anatomical region of the distal radius.

The exact anatomical contour, plate curvature, dimensions, and side-specific geometry should be confirmed from the official product technical drawings.

  1. Distal Head Section

The plate incorporates a widened distal head section intended to accommodate fixation within the distal portion of the plate.

According to the supplied product data:

Head Holes: 2

This value is reproduced exactly as stated in the supplied image. The exact meaning, configuration, and screw compatibility of these head holes should be verified from the manufacturer’s technical documentation.

  1. Shaft Section

The plate incorporates an elongated shaft containing fixation openings.

According to the supplied image, the shaft is available in:

3-hole and 5-hole configurations

This provides alternative plate configurations for different fixation requirements.

  1. Combination of Circular and Elongated Openings

The supplied product image visually shows different opening geometries within the plate, including circular fixation openings and an elongated slot within the shaft region.

The exact function of each opening—such as locking, compression, positioning, or adjustment—is not specified in the supplied product information and should therefore be confirmed from the approved surgical technique.

  1. Left and Right Configurations

The product is available in:

Left / Right

alignment options.

This supports selection according to the anatomical side being treated.

  1. Material Options

According to the supplied product data, the plate is available in:

SS316L

or

Titanium

The specific material grade for the Titanium version is not stated in the supplied image and should not be assumed.

Intended Use

The Locking Distal Radius Plate 2.4/2.7 mm is designed for use as part of a compatible orthopedic fixation system in the distal radius region, according to the approved indications, surgical technique, and Instructions for Use.

Potential use may involve stabilization of the distal radius where plate fixation is clinically indicated.

The specific fracture types, anatomical indications, patient eligibility, screw configuration, and permitted surgical applications must be confirmed from the manufacturer’s official regulatory documentation.

Plate selection may depend on factors including:

  • Anatomical side.
  • Fracture location and configuration.
  • Bone anatomy.
  • Plate length requirement.
  • Required shaft-hole configuration.
  • Bone quality.
  • Compatible screw selection.
  • Compatible instrumentation.
  • Surgical approach.
  • Preoperative planning.
  • Intraoperative assessment.

The implant should be selected and implanted by a qualified orthopedic surgeon according to the approved surgical technique and Instructions for Use.

Key Benefits

Left and Right Anatomical Options

The product is available in:

Left / Right

configurations, allowing selection according to the patient’s anatomical side.

Multiple Shaft Configurations

The plate is available with:

3 Shaft Holes

and

5 Shaft Holes

providing different configuration options according to the required fixation construct.

Two Material Options

According to the supplied image, the product can be manufactured from:

SS316L

or

Titanium

providing two material configurations within the product family.

2.4/2.7 mm Fixation System

The product is identified as:

Locking Distal Radius Plate 2.4/2.7 mm

indicating its association with a compatible 2.4/2.7 mm fixation system.

The exact compatible screw diameters and whether both sizes are used in all plate openings should be verified from the official technical documentation.

Anatomically Oriented Plate Design

The plate features a widened distal section and elongated shaft consistent with a plate intended for the distal radius region.

Its specific anatomical contour should be confirmed from the manufacturer’s approved drawings and product documentation.

Multiple Product Configurations

Based on the information visible in the image, the product family includes combinations of:

  • 2 alignments: Left / Right
  • 2 shaft configurations: 3 holes / 5 holes
  • 2 material options: SS316L / Titanium

This gives up to 8 basic alignment × shaft × material combinations, assuming every listed option is offered in every combination.

This configuration count should be confirmed from the official product catalog because the supplied image does not provide individual Cat. No. or GTIN records.

Technical Specifications

Specification Product Data
Product Name Locking Distal Radius Plate 2.4/2.7 mm
Category Trauma – Radius
Product Type Locking Orthopedic Plate
Anatomical Region Distal Radius
System Size 2.4/2.7 mm
Alignment Left, Right
Head Holes 2, as stated in supplied image
Shaft Holes 3, 5
Materials SS316L, Titanium
Cat. No. Not provided in supplied image
GTIN No. Not provided in supplied image
Plate Dimensions Not provided
Plate Thickness Not provided
Compatible Screw Details Not provided
Instrumentation Not provided

Technical Overview

Product Name: Locking Distal Radius Plate 2.4/2.7 mm

Product Category: Trauma – Radius

Product Type: Locking Orthopedic Fixation Plate

Anatomical Region: Distal Radius

System: 2.4/2.7 mm

Alignment Options: Left and Right

Head Holes: 2, according to supplied product data

Shaft Hole Options: 3 and 5

Material Options: SS316L and Titanium

Design: Anatomically oriented plate with widened distal section and elongated shaft

Fixation Concept: Plate-and-screw internal fixation using a compatible fixation system

Cat. No.: Not supplied

GTIN No.: Not supplied

Specific Titanium Grade: Not supplied

Specific Screw Compatibility: Not supplied

Product Features

  • Locking distal radius plate design.
  • Designed for the distal radius anatomical region.
  • Compatible with a 2.4/2.7 mm fixation system, according to the product name.
  • Available in Left and Right configurations.
  • Available with 3-hole and 5-hole shaft options.
  • Product data lists 2 head holes.
  • Available in SS316L.
  • Available in Titanium.
  • Features a widened distal plate section.
  • Features an elongated shaft section.
  • Includes multiple fixation openings.
  • Includes an elongated shaft opening visible in the supplied image.
  • Supports side-specific implant selection.
  • Supports selection of different shaft configurations.
  • Designed for use within a compatible orthopedic fixation construct.
  • Exact locking screw compatibility should be confirmed from official documentation.
  • Exact plate dimensions should be confirmed from official documentation.
  • Exact indications and surgical technique should be confirmed from the approved IFU.