Product Explanation
The Locking Dynamic Hip Plate 130°, B.C. Hole is an orthopedic fixation plate intended to form part of a compatible internal fixation construct involving the proximal femur / hip region.
A simplified fixation concept can be represented as:
Proximal Femur → Compatible Hip Fixation Component → 130° Dynamic Hip Plate → Compatible Fixation Screws → Internal Fixation Construct
The product is specifically identified as a:
Dynamic Hip Plate
with a:
130°
plate-barrel configuration.
According to the supplied product information, the plate also incorporates a:
38.0 mm Barrel
and is identified with:
B.C. Hole
configuration.
The shaft is available with:
2 / 3 / 4 / 5 / 6 / 8 / 10 / 12 Holes
providing multiple plate variants within the same product family.
Product Components and Design
- Dynamic Hip Plate Body
The implant consists of an elongated metallic fixation plate connected to a proximal barrel section.
The plate is specifically identified as:
Locking Dynamic Hip Plate
according to the supplied product designation.
The supplied image visually shows a longitudinal shaft with multiple fixation openings and an angled proximal barrel structure.
The exact plate length, width, thickness, contour, and plate-to-bone relationship should be confirmed from the manufacturer’s technical drawings.
- 130° Plate-Barrel Angle
The product name specifies:
130°
This represents an important geometric parameter of the plate configuration.
The 130° designation describes the angular relationship associated with the proximal plate-barrel geometry.
The exact reference lines and dimensional method used by the manufacturer to define this angle should be confirmed from the official technical drawing.
- Barrel Section
The proximal portion of the plate incorporates a cylindrical barrel.
According to the supplied product data:
Barrel Size: 38.0 mm
This represents a specified dimensional characteristic of the product.
The supplied image does not clarify whether the 38.0 mm value refers to barrel length or another defined barrel dimension. Therefore, it should be retained exactly as:
Barrel Size: 38.0 mm
until the official dimensional drawing confirms its precise definition.
- B.C. Hole Configuration
The supplied product data identifies:
B.C. Hole
under the Alignment field.
However, B.C. Hole appears to describe the plate’s hole configuration rather than an anatomical alignment.
The exact meaning of the abbreviation B.C. is not defined in the supplied image.
Therefore, it should be preserved exactly as:
B.C. Hole
without expanding the abbreviation unless confirmed by the manufacturer’s official documentation.
- Shaft Section
The plate is available with:
2 Shaft Holes
3 Shaft Holes
4 Shaft Holes
5 Shaft Holes
6 Shaft Holes
8 Shaft Holes
10 Shaft Holes
12 Shaft Holes
This provides eight listed shaft-hole configurations within the product family.
The exact physical plate length corresponding to each shaft-hole configuration is not supplied.
- Multiple Fixation Opening Geometries
The supplied product image visually shows multiple openings distributed along the longitudinal shaft.
Different opening geometries are visible.
The exact function of each opening—such as locking fixation, conventional fixation, compression, positioning, or another fixation role—is not specified in the supplied product data and should be confirmed from the approved surgical technique.
- Material Options
According to the supplied product information, the plate is available in:
SS316L
and
Titanium
The exact Titanium alloy or grade is not specified in the supplied image and should be confirmed from the manufacturer’s material specification.
Intended Use
The Locking Dynamic Hip Plate 130°, B.C. Hole is designed for use as part of a compatible orthopedic fixation system involving the proximal femur / hip region, according to the approved indications, surgical technique, and Instructions for Use.
The product designation identifies it as a Dynamic Hip Plate within the Trauma – Femur product family.
Potential applications may involve proximal femoral fixation where this specific dynamic hip plate configuration is included within the manufacturer’s approved indications.
The exact fracture types, fracture classifications, anatomical indications, compatible hip fixation components, surgical approach, fixation strategy, contraindications, and patient-selection criteria should be confirmed from the official product documentation.
Implant selection may depend on factors including:
- Proximal femur anatomy.
- Fracture location and configuration.
- Required plate-barrel angle.
- Required barrel size.
- Required shaft-hole configuration.
- Required plate length.
- Bone dimensions.
- Bone quality.
- Compatible hip fixation component selection.
- Compatible screw selection.
- Compatible instrumentation.
- Surgical approach.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Benefits
130° Dynamic Hip Plate Configuration
The product is specifically identified as:
Locking Dynamic Hip Plate 130°
providing a defined angular plate configuration within a compatible proximal femur fixation system.
Specified 38.0 mm Barrel Size
According to the supplied product data:
Barrel Size: 38.0 mm
providing a defined barrel configuration for implant identification and selection.
Eight Shaft-Hole Configurations
The product family includes:
2 / 3 / 4 / 5 / 6 / 8 / 10 / 12 Shaft Holes
providing a broad range of plate configurations.
This supports selection among different plate variants according to the required fixation construct and surgical plan.
B.C. Hole Configuration
The product is identified with:
B.C. Hole
configuration.
This distinguishes it from other possible hole configurations within the plate family.
The exact technical meaning and functionality of B.C. Hole should be confirmed from the manufacturer’s documentation.
Femur / Hip Fixation Product Family
The supplied image categorizes the product under:
Trauma – Femur
and the product name identifies it as a:
Dynamic Hip Plate
indicating its association with a proximal femur / hip fixation system.
Two Material Options
According to the supplied product information, the plate is available in:
SS316L
and
Titanium
Multiple Plate-Length Configurations
The shaft-hole options:
2 → 3 → 4 → 5 → 6 → 8 → 10 → 12
provide multiple plate configurations.
The actual physical plate lengths are not supplied and should be confirmed from the manufacturer’s dimensional specifications.
Multiple Product Variants
Based strictly on the supplied image, the family includes:
- 1 plate angle: 130°
- 1 listed barrel size: 38.0 mm
- 1 B.C. Hole configuration
- 8 shaft-hole options: 2 / 3 / 4 / 5 / 6 / 8 / 10 / 12
- 2 material options: SS316L / Titanium
If each shaft-hole configuration is available in both materials, this could represent up to 16 basic shaft × material configurations for the supplied 130° / 38.0 mm barrel specification.
The exact number of commercially available variants should be confirmed from the official Cat. No. table.
Technical Specifications
| Specification | Product Data |
| Product Name | Locking Dynamic Hip Plate 130°, B.C. Hole |
| Product Category | Trauma – Femur |
| Product Type | Locking Dynamic Hip Plate |
| Anatomical Region | Proximal Femur / Hip region |
| Plate Angle | 130° |
| Barrel Size | 38.0 mm |
| Hole Configuration | B.C. Hole |
| Shaft Hole Options | 2, 3, 4, 5, 6, 8, 10, 12 |
| Number of Shaft-Hole Options | 8 |
| Materials | SS316L, Titanium |
| Potential Basic Configurations | Up to 16, subject to catalog confirmation |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
| Plate Lengths | Not provided |
| Plate Width | Not provided |
| Plate Thickness | Not provided |
| Barrel Diameter | Not provided |
| Exact Definition of 38.0 mm Barrel Size | Not provided |
| Compatible Hip Fixation Component | Not provided |
| Compatible Screw Details | Not provided |
| B.C. Hole Definition | Not provided |
| Titanium Grade | Not provided |
| Compatible Instrumentation | Not provided |
Technical Overview
Product Name: Locking Dynamic Hip Plate 130°, B.C. Hole
Product Category: Trauma – Femur
Product Type: Locking Dynamic Hip Plate
Anatomical Region: Proximal Femur / Hip region
Plate Angle: 130°
Barrel Size: 38.0 mm
Hole Configuration: B.C. Hole
Shaft Hole Options: 2, 3, 4, 5, 6, 8, 10, and 12
Material Options: SS316L and Titanium
Plate Geometry: Angled proximal barrel connected to an elongated fixation shaft
Fixation Concept: Plate-based internal fixation using compatible hip fixation components and screws
Alignment: Supplied as “B.C. Hole”; more appropriately treated as a hole configuration pending catalog confirmation
Side-Specific Design: Not specified
Cat. No.: Not supplied
GTIN No.: Not supplied
Plate Lengths: Not supplied
Specific Titanium Grade: Not supplied
Specific Screw Compatibility: Not supplied
Exact B.C. Definition: Not supplied
Product Features
- Locking orthopedic fixation plate design.
- Specifically identified as a Dynamic Hip Plate.
- Included within the Trauma – Femur category.
- Features a 130° plate-barrel configuration.
- Specified with a 38.0 mm barrel size.
- Identified with a B.C. Hole configuration.
- Available with 2 shaft holes.
- Available with 3 shaft holes.
- Available with 4 shaft holes.
- Available with 5 shaft holes.
- Available with 6 shaft holes.
- Available with 8 shaft holes.
- Available with 10 shaft holes.
- Available with 12 shaft holes.
- Provides eight shaft-hole configurations.
- Available in SS316L.
- Available in Titanium.
- Features an angled proximal barrel section.
- Features an elongated fixation shaft.
- Includes multiple visible fixation openings.
- Supports multiple potential plate-length configurations.
- Exact definition of the 38.0 mm barrel size should be confirmed from the manufacturer’s dimensional drawing.
- Exact compatible hip fixation component should be confirmed from official system documentation.
- Exact meaning of B.C. Hole should be confirmed from the manufacturer.
- Exact compatible screw types and diameters should be confirmed from the product system documentation.
- Exact plate lengths, width, thickness, barrel diameter, and other dimensional parameters should be confirmed from the manufacturer’s technical drawings.
- Individual Cat. No. and GTIN No. should be added when the official product table is available.
- Approved indications, contraindications, and surgical technique should be confirmed from the manufacturer’s Instructions for Use (IFU).


Reviews