The Anterior Cervical Locked Plate [Titanium] is a component of an Anterior Cervical Spine Fixation System, designed to be positioned along the anterior aspect of the cervical vertebrae as part of an internal fixation construct according to the approved indications and surgical technique.
The product features a low-profile cervical plate geometry with multiple screw fixation points and integrated locking features designed to work with compatible cervical fixation screws. Together, the plate and screws form a cervical fixation construct intended to stabilize the targeted vertebral segments according to the surgical plan.
According to the provided product information, the plate material is:
Material: Titanium
The product family is listed under:
Cat. No.: AMS 514.200.000
The plate is available in lengths ranging from 34 mm to 58 mm, with regular 2 mm increments, providing a total of 13 product configurations. This allows the surgeon to select an appropriate plate length according to cervical anatomy, vertebral spacing, fixation level, required plate coverage, and intraoperative requirements.
Each length is assigned an individual Cat. No. and GTIN No., supporting accurate implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.
Product Explanation
The Anterior Cervical Locked Plate is a spinal implant used as part of an anterior cervical internal fixation system. It is positioned on the anterior surface of the cervical spine and fixed to the vertebrae using compatible screws.
A simplified fixation concept can be represented as:
Cervical Vertebrae → Compatible Cervical Screws → Anterior Cervical Locked Plate → Cervical Fixation Construct
Plate length and screw positioning are selected according to the patient’s anatomy, the number and position of the targeted vertebral levels, and the surgical plan.
Product Components and Design
- Titanium Plate Body
The main structural body of the implant is manufactured from Titanium, according to the supplied product data.
It functions as the primary plate component positioned along the anterior cervical spine.
- Screw Fixation Holes
The plate includes multiple screw fixation holes designed to receive compatible cervical fixation screws.
These fixation points are distributed along the plate according to the implant geometry.
- Locking Features
The product is identified as a Locked Plate, and the design visibly incorporates locking features around the screw fixation areas.
The specific locking mechanism, locking angle, or screw-locking technology is not defined in the provided table and should be confirmed from the official technical documentation.
- Central Windows / Openings
The plate includes central openings or windows as part of its geometry.
The dimensions and intended technical function of these openings are not specified in the supplied data.
- Length-Specific Configurations
Available lengths are:
34 / 36 / 38 / 40 / 42 / 44 / 46 / 48 / 50 / 52 / 54 / 56 / 58 mm
This provides multiple options for implant selection.
Intended Use
The Anterior Cervical Locked Plate is designed for use within compatible anterior cervical spine fixation systems, according to the approved indications and Instructions for Use.
Potential applications, when included within the approved indications, may include:
- Anterior cervical spine fixation.
- Cervical vertebral stabilization.
- Anterior cervical fusion constructs.
- Cervical spinal reconstruction procedures.
- Plate-and-screw cervical fixation.
- Internal fixation following appropriate cervical spine procedures.
Plate selection depends on factors including:
- Cervical anatomy.
- Number of vertebral levels.
- Vertebral spacing.
- Fixation site.
- Screw positioning.
- Required plate coverage.
- Bone quality.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified spine surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Benefits
Titanium Implant Material
The product is specified as:
Material: Titanium
according to the supplied catalog information.
Locking Plate Configuration
The implant features a locked cervical plate design intended to work with a compatible screw and locking system.
Wide Length Range
Available lengths extend from:
34 mm to 58 mm
providing multiple options for cervical plate selection.
2 MM Length Increments
The product range increases in regular:
2 mm increments
allowing more precise selection between available plate lengths.
Multiple Fixation Points
The plate incorporates multiple screw fixation interfaces for construction of a plate-and-screw cervical fixation system.
13 Product Configurations
The product family includes:
13 different length configurations
within one plate system.
Product Traceability
Each length has an individual Cat. No. and GTIN No. to support:
- Implant identification.
- Product traceability.
- Surgical set preparation.
- Procurement.
- Inventory management.
- Stock control.
Technical Specifications
| Length | Cat. No. | GTIN No. |
| 34 mm | AMS 514.200.034T | 6221361019072 |
| 36 mm | AMS 514.200.036T | 6221361019102 |
| 38 mm | AMS 514.200.038T | 6221361019133 |
| 40 mm | AMS 514.200.040T | 6221361019164 |
| 42 mm | AMS 514.200.042T | 6221361019195 |
| 44 mm | AMS 514.200.044T | 6221361019225 |
| 46 mm | AMS 514.200.046T | 6221361019256 |
| 48 mm | AMS 514.200.048T | 6221361019287 |
| 50 mm | AMS 514.200.050T | 6221361019317 |
| 52 mm | AMS 514.200.052T | 6221361019348 |
| 54 mm | AMS 514.200.054T | 6221361043824 |
| 56 mm | AMS 514.200.056T | 6221361019379 |
| 58 mm | AMS 514.200.058T | 6221361019409 |
Technical Overview
Product Name: Anterior Cervical Locked Plate
Material: Titanium
Product Type: Anterior Cervical Spine Locking Plate
Product Category: Spinal Internal Fixation Implant
General Cat. No.: AMS 514.200.000
Available Lengths: 34–58 mm
Length Increment: 2 mm
Number of Configurations: 13
Design: Multi-Hole Anterior Cervical Locked Plate
Fixation Concept: Plate-and-Screw Cervical Fixation
Anatomical Application: Cervical Spine
Identification: Individual Cat. No. and GTIN No. for each length
Product Features
- Anterior Cervical Locked Plate Design.
- Manufactured from Titanium according to the catalog.
- Designed for compatible cervical spine fixation systems.
- Multi-hole plate configuration.
- Multiple screw fixation interfaces.
- Integrated locking features.
- Central openings incorporated into the plate geometry.
- Available in 13 length configurations.
- Length range from 34 to 58 mm.
- Regular 2 mm increments.
- Provides multiple options for preoperative plate selection.
- Supports intraoperative implant selection according to cervical anatomy.
- Individual Cat. No. for each length.
- Individual GTIN No. for each configuration.
- Supports implant identification, traceability, procurement, and inventory management.


Reviews
There are no reviews yet.