Product Explanation
The Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread is an orthopedic fixation screw intended to form part of a compatible guided fixation construct.
A simplified fixation concept can be represented as:
Guide Wire / Prepared Fixation Path → 6.0 mm Cannulated Partial-Thread Screw → Compatible Bone / Fixation Construct
The product combines four supplied characteristics:
Cannulated
Self Tapping
Ø 6.0 mm
Partial Thread
The cannulated designation indicates the presence of an axial lumen intended for use with compatible guide-wire-based instrumentation according to the approved surgical technique.
The partial-thread configuration indicates that only part of the screw shaft carries external bone-engaging threads, while another section remains unthreaded.
The exact threaded-to-unthreaded shaft ratio is not provided in the supplied data.
Product Components and Design
- Cannulated Screw Body
The product is specifically identified as:
Cannulated Screw
indicating the presence of an internal axial lumen.
The exact:
- Cannulation diameter.
- Guide-wire diameter.
- Guide-wire compatibility.
- Cannulation tolerances.
- Internal lumen geometry.
are not supplied.
The safest technical wording is:
Cannulation: Present — exact internal diameter and guide-wire compatibility not specified
- Ø 6.0 mm Nominal Diameter
The product title specifies:
Ø 6.0 mm
as the nominal screw diameter.
The supplied data does not separately define:
- Major thread diameter.
- Minor / core diameter.
- Thread depth.
- Thread pitch.
- Thread profile.
- Dimensional tolerances.
These parameters should be confirmed from the manufacturer’s dimensional drawing.
- Partial-Thread Configuration
The product is specifically identified as:
Partial Thread
The supplied image visually shows a threaded distal region and a comparatively smooth unthreaded shaft section.
The exact:
- Threaded length.
- Unthreaded shaft length.
- Thread-to-shaft transition.
- Thread pitch.
- Thread depth.
are not provided.
- Self-Tapping Design
The screw is specifically identified as:
Self Tapping
indicating a manufacturer-defined self-tapping thread-entry / tip configuration.
The exact:
- Cutting flute geometry.
- Tip geometry.
- Thread-start configuration.
- Drilling requirements.
- Need for separate tapping.
are not defined in the supplied image.
- Threaded Distal Section
The distal portion incorporates external threads intended for bone engagement within the compatible fixation construct.
The exact:
- Thread pitch.
- Thread depth.
- Thread lead.
- Core diameter.
- Thread flank geometry.
should be confirmed from the manufacturer’s technical documentation.
- Unthreaded Shaft Section
A substantial portion of the screw shaft appears smooth and unthreaded, consistent with the product’s:
Partial Thread
designation.
The exact unthreaded shaft length may vary by overall screw length and should be confirmed from the official product drawings.
- Distal Tip
The supplied image shows a defined distal tip associated with the product’s Self Tapping designation.
However, the source does not state:
Self Drilling
Therefore, self-drilling capability should not be added to the technical specification without official confirmation.
- Screw Head and Drive Interface
The supplied image shows a proximal screw head with a central opening consistent with cannulation and an insertion interface.
However, the exact drive type is not specified.
Therefore, the product should not be described as:
Hex / Torx / Star / Stardrive / other
without manufacturer confirmation.
Length Configurations
According to the supplied product information:
Length: 40–115 mm (5 mm Variation)
The available lengths are:
| No. | Length |
| 1 | 40 mm |
| 2 | 45 mm |
| 3 | 50 mm |
| 4 | 55 mm |
| 5 | 60 mm |
| 6 | 65 mm |
| 7 | 70 mm |
| 8 | 75 mm |
| 9 | 80 mm |
| 10 | 85 mm |
| 11 | 90 mm |
| 12 | 95 mm |
| 13 | 100 mm |
| 14 | 105 mm |
| 15 | 110 mm |
| 16 | 115 mm |
Therefore:
Total Length Configurations: 16
Material Options
According to the supplied product information, the screw is available in:
SS316L
and
Titanium
The exact Titanium grade or alloy is not specified and should be confirmed from the manufacturer’s official material documentation.
Intended Use
The Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread is designed for use as part of a compatible orthopedic fixation system according to the approved indications, surgical technique, and Instructions for Use.
Potential applications may involve fixation where a 6.0 mm cannulated partial-thread screw is specified by the manufacturer.
The exact anatomical indications, compatible implant systems, guide-wire requirements, insertion technique, and bone-preparation requirements are not supplied in the product image.
Screw selection may depend on factors including:
- Anatomical location.
- Bone dimensions.
- Required screw diameter.
- Required screw length.
- Requirement for partial-thread fixation.
- Bone quality.
- Required fixation construct.
- Compatible guide wire.
- Screw trajectory.
- Compatible drilling instrumentation.
- Compatible depth gauge.
- Compatible screwdriver.
- Preoperative planning.
- Intraoperative measurement.
The screw should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Benefits
Cannulated Design
The product is specifically identified as:
Cannulated
indicating an axial lumen intended for use within a compatible guided fixation system.
The exact guide-wire specification should be confirmed from official documentation.
Partial-Thread Configuration
The product is specifically identified as:
Partial Thread
providing a threaded distal region combined with an unthreaded shaft section.
The exact biomechanical effect of this configuration should be confirmed from the manufacturer’s approved documentation.
Self-Tapping Design
The product is specifically identified as:
Self Tapping
providing a manufacturer-defined self-tapping tip / thread-entry configuration.
Ø 6.0 mm Nominal Diameter
The product provides a nominal:
6.0 mm screw diameter
within the compatible orthopedic fixation system.
40–115 mm Length Range
The screw is available from:
40 mm to 115 mm
providing a broad range of lengths.
5 mm Length Increments
The complete supplied range uses:
5 mm increments
for standardized screw-length progression.
16 Length Configurations
The complete available range is:
40 / 45 / 50 / 55 / 60 / 65 / 70 / 75 / 80 / 85 / 90 / 95 / 100 / 105 / 110 / 115 mm
providing:
16 individual length options
Two Material Options
According to the supplied product data, the screw is available in:
SS316L
and
Titanium
Multiple Product Variants
Based strictly on the supplied product information, the family includes:
- 1 nominal diameter: Ø 6.0 mm
- 1 cannulated configuration
- 1 partial-thread configuration
- 1 self-tapping configuration
- 16 length options
- 2 material options: SS316L / Titanium
If every listed length is available in both materials, this could theoretically represent:
16 × 2 = up to 32 basic length × material configurations
The exact commercial matrix should be confirmed from the official Cat. No. / GTIN table.
Technical Specifications
| Specification | Product Data |
| Product Name | Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread |
| Product Type | Cannulated Orthopedic Fixation Screw |
| Cannulated | Yes |
| Design | Self Tapping |
| Thread Configuration | Partial Thread |
| Nominal Diameter | Ø 6.0 mm |
| Length Range | 40–115 mm |
| Length Increment | 5 mm |
| Available Lengths | 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115 mm |
| Number of Length Options | 16 |
| Materials | SS316L, Titanium |
| Potential Basic Configurations | Up to 32, subject to catalog confirmation |
| Cannulation Diameter | Not provided |
| Compatible Guide Wire | Not provided |
| Guide-Wire Diameter | Not provided |
| Thread Pitch | Not provided |
| Thread Depth | Not provided |
| Core Diameter | Not provided |
| Threaded Length | Not provided |
| Unthreaded Shaft Length | Not provided |
| Drive Interface | Not provided |
| Self Drilling | Not specified |
| Locking Head | Not specified |
| Tip Geometry | Self-tapping; exact geometry not provided |
| Compatible Implant / Plate | Not provided |
| Compatible Instrumentation | Not provided |
| Titanium Grade | Not provided |
| Cat. No. | Not provided |
| GTIN No. | Not provided |
Technical Overview
Product Name: Cannulated Screw, Self Tapping Ø 6.0 mm – Partial Thread
Product Type: Orthopedic Cannulated Fixation Screw
Nominal Diameter: Ø 6.0 mm
Cannulation: Present
Self Tapping: Yes
Thread Configuration: Partial Thread
Length Range: 40–115 mm
Length Increment: 5 mm
Total Length Options: 16
Material Options: SS316L and Titanium
Screw Geometry: Cannulated screw with threaded distal region and unthreaded shaft section
Fixation Concept: Guided screw fixation within a compatible orthopedic fixation construct
Self Drilling: Not specified
Locking Head: Not specified
Cannulation Details: Not supplied
Guide-Wire Compatibility: Not supplied
Thread Geometry: Not supplied
Drive Interface: Not supplied
Compatible Implant System: Not supplied
Specific Titanium Grade: Not supplied
Cat. No.: Not supplied
GTIN No.: Not supplied
Product Features
- Orthopedic cannulated fixation screw.
- Specifically identified as Self Tapping.
- Specifically identified as Partial Thread.
- Nominal diameter of Ø 6.0 mm.
- Includes an axial cannulation according to the product designation.
- Features a threaded distal section.
- Features an unthreaded shaft section.
- Available from 40 mm to 115 mm.
- Uses 5 mm length increments.
- Provides 16 length configurations.
- Available in SS316L.
- Available in Titanium.
- Includes a proximal screw head.
- Includes a central opening consistent with cannulation.
- Exact cannulation diameter should be confirmed from technical drawings.
- Exact guide-wire diameter should be confirmed.
- Exact thread pitch and thread depth should be confirmed.
- Exact threaded and unthreaded section lengths should be confirmed.
- Exact core diameter should be confirmed.
- Exact head dimensions should be confirmed.
- Exact drive interface should be confirmed.
- Self-drilling capability is not specified in the supplied product data.
- Locking-head configuration is not specified in the supplied product data.
- Exact insertion technique should be confirmed from the manufacturer’s surgical technique.
- Exact compatible implant system should be confirmed from official documentation.
- Exact Titanium alloy should be confirmed.
- Individual Cat. No. and GTIN No. should be added when the official product matrix is available.
- Approved indications, contraindications, and insertion technique should be confirmed from the manufacturer’s Instructions for Use (IFU).


Reviews