The Humeral Interlocking Nail is intended to be used as part of a compatible humeral internal fixation system according to the approved indications, surgical technique, and Instructions for Use. The exact fracture indications, anatomical requirements, compatible locking screws, instrumentation, and surgical approach should be confirmed from the official technical documentation.
The product is shown as a long intramedullary humeral nail with interlocking fixation features. Both material variants have an 8 mm diameter and are available in lengths from 160 mm to 340 mm. Selection of nail length, diameter, material variant, and associated fixation components should be performed according to the applicable anatomy, fracture characteristics, bone dimensions, patient requirements, and approved surgical plan.
According to the provided product information, the product family is identified as:
Product Name: Humeral Interlocking Nail
The product family has the following specifications shown in the image:
Diameter: 8 mm
Material Variants: TIT and Stainless Steel (316L)
Available Lengths: 160 mm, 180 mm, 200 mm, 220 mm, 240 mm, 260 mm, 280 mm, 300 mm, 320 mm, and 340 mm
Length Increment: 20 mm
Number of Configurations: 10 per material variant; 20 total identified entries
The material notation TIT is reproduced exactly as shown in the supplied image. Its expanded material designation and applicable material standard should be confirmed from the official technical documentation.
Each length and material variant is assigned an individual Cat. No. and GTIN No., supporting accurate implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.
Product Explanation
The Humeral Interlocking Nail is an orthopedic intramedullary fixation implant used within a compatible humeral fracture fixation construct. It is positioned within the humeral medullary canal and used with compatible interlocking fixation components according to the approved surgical technique and product documentation.
A simplified fixation concept can be represented as:
Humeral Fracture / Prepared Humeral Canal → Humeral Interlocking Nail → Compatible Locking Components → Humeral Internal Fixation Construct
Nail diameter and length are selected according to the patient’s anatomy, humeral canal dimensions, fracture location and pattern, required fixation levels, bone quality, and the surgical plan. Material selection should be made according to the applicable product documentation and clinical requirements.
Product Components and Design
- Intramedullary Nail Body
The supplied image shows long intramedullary nail components intended for placement within the humerus. Both variants are identified with an 8 mm diameter. The detailed cross-sectional geometry, curvature, wall thickness, and mechanical specifications are not defined in the supplied image.
- Interlocking Fixation Features
The product is identified as an Interlocking Nail and the supplied anatomical illustrations show fixation components associated with the nail. The exact number, position, dimensions, orientation, and compatibility of the locking holes or locking screws should be confirmed from the official technical documentation.
- Proximal and Distal Fixation
The product illustrations represent a humeral fixation construct with proximal and distal fixation features. The precise locking configuration, screw specifications, targeting method, and instrumentation are not specified in the supplied image.
- Material Variants
The supplied image identifies two material variants:
- TIT, reproduced as shown in the image. The expanded designation should be confirmed from official documentation.
- Stainless Steel (316L).
The material variant must be matched with the applicable Cat. No., GTIN No., surgical set, and product documentation.
- Diameter Configuration
Both material variants are identified with a diameter of:
8 mm
- Length-Specific Configurations
Each material variant is available in ten length options:
160 / 180 / 200 / 220 / 240 / 260 / 280 / 300 / 320 / 340 mm
This provides multiple options for implant selection according to humeral anatomy and fracture requirements.
Intended Use
The Humeral Interlocking Nail is designed for use within a compatible humeral internal fixation system according to the approved indications, surgical technique, and Instructions for Use.
The supplied image alone does not define the complete clinical indication, fracture classification, patient population, associated locking screws, surgical approach, contraindications, or material-selection criteria. These details should be confirmed from the official product documentation and applicable regulatory information.
Nail selection and use depend on factors including:
- Humeral anatomy.
- Humeral canal dimensions.
- Fracture location and pattern.
- Required nail diameter.
- Required nail length.
- Proximal and distal fixation requirements.
- Material compatibility and applicable product requirements.
- Bone quality.
- Compatible locking screws and instrumentation.
- Preoperative planning.
- Intraoperative assessment.
The implant should be selected and implanted by a qualified orthopedic surgeon in accordance with the approved surgical technique and Instructions for Use.
Key Features
8 mm Nail Diameter
Both material variants are identified with a diameter of:
8 mm
Two Material Variants
The supplied image presents two variants:
- TIT, as written in the image.
- Stainless Steel (316L).
The expanded material designation for TIT should be confirmed from official technical documentation.
Length Range
Each material variant is available in lengths ranging from:
160 mm to 340 mm
providing multiple options for humeral implant selection.
20 mm Length Increments
Each product range increases in regular:
20 mm increments
across ten listed length configurations.
Interlocking Nail Design
The product is identified as a Humeral Interlocking Nail and is shown as a long intramedullary nail used with associated fixation components in humeral fixation illustrations.
20 Identified Product Entries
The image presents ten length configurations for each of two material variants, resulting in:
20 identified length-and-material entries
Product Traceability
Each length and material variant has an individual Cat. No. and GTIN No. to support implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.
Technical Specifications — TIT Variant
| Material | Diameter | Length | Cat. No. | GTIN No. |
| TIT | 8 mm | 160 mm | AMS 802.008.016T | 6221361005228 |
| TIT | 8 mm | 180 mm | AMS 802.008.018T | 6221361005242 |
| TIT | 8 mm | 200 mm | AMS 802.008.020T | 6221361005266 |
| TIT | 8 mm | 220 mm | AMS 802.008.022T | 6221361005280 |
| TIT | 8 mm | 240 mm | AMS 802.008.024T | 6221361005303 |
| TIT | 8 mm | 260 mm | AMS 802.008.026T | 6221361000025 |
| TIT | 8 mm | 280 mm | AMS 802.008.028T | 6221361000049 |
| TIT | 8 mm | 300 mm | AMS 802.008.030T | 6221361000063 |
| TIT | 8 mm | 320 mm | AMS 802.008.032T | 6221361000087 |
| TIT | 8 mm | 340 mm | AMS 802.008.034T | 6221361000100 |
Technical Specifications — Stainless Steel (316L) Variant
| Material | Diameter | Length | Cat. No. | GTIN No. |
| Stainless Steel (316L) | 8 mm | 160 mm | AMS 802.008.016S | 6221361005013 |
| Stainless Steel (316L) | 8 mm | 180 mm | AMS 802.008.018S | 6221361005037 |
| Stainless Steel (316L) | 8 mm | 200 mm | AMS 802.008.020S | 6221361005051 |
| Stainless Steel (316L) | 8 mm | 220 mm | AMS 802.008.022S | 6221361005075 |
| Stainless Steel (316L) | 8 mm | 240 mm | AMS 802.008.024S | 6221361005099 |
| Stainless Steel (316L) | 8 mm | 260 mm | AMS 802.008.026S | 6221361005112 |
| Stainless Steel (316L) | 8 mm | 280 mm | AMS 802.008.028S | 6221361005136 |
| Stainless Steel (316L) | 8 mm | 300 mm | AMS 802.008.030S | 6221361005150 |
| Stainless Steel (316L) | 8 mm | 320 mm | AMS 802.008.032S | 6221361005174 |
| Stainless Steel (316L) | 8 mm | 340 mm | AMS 802.008.034S | 6221361005198 |
Variant Comparison
| Specification | TIT Variant | Stainless Steel Variant |
| Diameter | 8 mm | 8 mm |
| Material notation | TIT, as shown in the image | Stainless Steel (316L) |
| Available lengths | 160–340 mm | 160–340 mm |
| Length increment | 20 mm | 20 mm |
| Number of configurations | 10 | 10 |
| Cat. No. suffix shown | T | S |
| GTIN assignment | Individual GTIN for each length | Individual GTIN for each length |
The table above summarizes only the information visible in the supplied image. The Cat. No. suffixes are reported as shown and should not be interpreted as material codes beyond the material information explicitly displayed in the image.
Technical Overview
Product Name: Humeral Interlocking Nail
Product Type: Intramedullary Humeral Fixation Implant
Product Category: Orthopedic Internal Fixation Implant
Diameter: 8 mm
Material Variants: TIT and Stainless Steel (316L)
Available Lengths: 160–340 mm
Length Increment: 20 mm
Number of Configurations: 10 per material variant; 20 total identified entries
Design: Humeral Interlocking Intramedullary Nail
Fixation Concept: Intramedullary Nail with Interlocking Fixation
Anatomical Application: Humerus
Identification: Individual Cat. No. and GTIN No. for each length-and-material configuration
Product Features
- Humeral Interlocking Nail design.
- 8 mm diameter for both displayed material variants.
- TIT material notation shown for one variant.
- Stainless Steel (316L) identified for the second variant.
- Intramedullary humeral fixation concept.
- Interlocking fixation design intended for use with compatible locking components.
- Available in ten lengths per material variant.
- Length range from 160 mm to 340 mm.
- Regular 20 mm length increments.
- 20 identified length-and-material entries in total.
- Supports implant selection according to humeral anatomy and fracture requirements.
- Individual Cat. No. for each length and material variant.
- Individual GTIN No. for each configuration.
•Supports implant identification, traceability, procurement, and inventory management.


Reviews