The Slotted Connector is a titanium spinal fixation component designed for integration within compatible posterior spinal instrumentation systems according to the manufacturer’s approved indications and surgical technique.
The implant features a compact connector body incorporating a slotted fixation interface at one end and an additional connection / fastening section at the opposite end. This geometry allows the component to act as a mechanical interface between compatible spinal fixation elements within the overall construct.
According to the supplied catalog information, the product is manufactured from:
Material: Titanium
The product family is listed under:
Cat. No.: AMS 518.003.000
The Slotted Connector is available in six configurations:
Universal / Standard / Long / Short / Extra-Long / Extra-Short
This range provides multiple options for component selection according to construct geometry, relative component position, required connector reach, available surgical space, and intraoperative requirements.
Each variant is assigned an individual Cat. No. and GTIN No., supporting accurate implant identification, product traceability, surgical set preparation, procurement, inventory management, and stock control.
Product Explanation
The Slotted Connector is a mechanical spinal fixation component used to create a connection between compatible elements within a spinal stabilization construct.
A simplified configuration can be represented as:
Spinal Fixation Component → Slotted Connector → Compatible Rod / Connector / Fixation Element → Spinal Construct
The elongated slot provides a connection interface that may accommodate component positioning within the limits of the system design.
The exact degree of adjustment and compatible component dimensions are not specified in the supplied catalog.
Product Components and Design
- Titanium Connector Body
The main structural component is manufactured from Titanium, according to the supplied product data.
It forms the mechanical bridge between compatible spinal fixation components.
- Slotted Connection Interface
One end incorporates an elongated slot-shaped opening, which forms one of the principal fixation / connection interfaces.
The supplied data does not specify:
- Slot length
- Slot width
- Adjustment range
- Compatible bolt or screw size
- Opposite Connection Body
The opposite end contains a compact mechanical connection section intended to interface with another compatible spinal fixation component.
- Fastening / Locking Element
A fastening feature is visible within the connector body.
Its exact:
- Thread specification
- Locking mechanism
- Tool interface
- Recommended tightening torque
are not provided in the supplied catalog data.
- Configuration-Specific Variants
The product family includes:
- Universal
- Standard
- Long
- Short
- Extra-Long
- Extra-Short
allowing selection according to the required construct configuration.
Intended Use
The Slotted Connector is intended for use within compatible spinal fixation systems, according to the manufacturer’s approved indications and Instructions for Use.
Potential applications, where included within the approved indications, may include:
- Posterior spinal stabilization constructs.
- Connecting compatible spinal rods and fixation components.
- Offset or transitional connections within spinal instrumentation.
- Multi-component posterior fixation assemblies.
- Spinal deformity correction constructs.
- Spinal reconstruction procedures.
Selection of the appropriate connector type depends on:
- Spinal construct geometry.
- Distance between fixation components.
- Required connector length.
- Relative component position.
- Compatible rod / connector dimensions.
- Available surgical space.
- Preoperative planning.
- Intraoperative assessment.
The component should be selected and installed by a qualified spine surgeon according to the approved surgical technique and IFU.
Key Benefits
Titanium Material
The supplied catalog specifies:
Material: Titanium
Slotted Connection Geometry
The implant features an elongated slot designed as part of the mechanical connection interface.
Six Configuration Options
Available types include:
Universal | Standard | Long | Short | Extra-Long | Extra-Short
providing a broad selection for different construct requirements.
Construct Positioning Flexibility
Multiple connector lengths / types provide options for different component positions and construct layouts.
Compact Mechanical Connector Design
The implant combines a slotted interface and fastening body within a compact spinal connector component.
Compatible System Integration
Designed to integrate with compatible spinal fixation elements according to the system configuration.
Product Traceability
Each configuration has a dedicated Cat. No. and GTIN No. to support:
- Implant identification.
- Product traceability.
- Surgical set preparation.
- Procurement.
- Inventory management.
- Stock control.
Technical Specifications
| Type | Cat. No. | GTIN No. |
| Universal | AMS 518.003.000T | 6221361021815 |
| Standard | AMS 518.003.001T | 6221361021846 |
| Long | AMS 518.003.002T | 6221361021877 |
| Short | AMS 518.003.003T | 6221361021907 |
| Extra-Long | AMS 518.003.004T | 6221361021938 |
| Extra-Short | AMS 518.003.005T | 6221361021969 |
Technical Overview
Product Name: Slotted Connector
Material: Titanium
Product Type: Spinal Fixation Connector
Product Category: Posterior Spinal Fixation Component
General Cat. No.: AMS 518.003.000
Available Types: Universal / Standard / Long / Short / Extra-Long / Extra-Short
Number of Configurations: 6
Design: Connector with Slotted Fixation Interface
Fixation Concept: Mechanical Connection between compatible spinal fixation components
Anatomical Application: Spine
Identification: Individual Cat. No. and GTIN No. for each configuration
Product Features
- Slotted Spinal Connector Design.
- Manufactured from Titanium according to the catalog.
- Designed for compatible spinal fixation systems.
- Elongated slotted connection interface.
- Integrated mechanical fastening section.
- Compact connector geometry.
- Available in 6 configurations.
- Types: Universal, Standard, Long, Short, Extra-Long, and Extra-Short.
- Supports different construct geometries and connector positioning requirements.
- Provides multiple options for preoperative component selection.
- Supports intraoperative construct configuration.
- Individual Cat. No. for each type.
- Individual GTIN No. for each variant.
- Supports implant identification, traceability, procurement, and inventory management.


Reviews